[1]
|
The IEEE Standards Association, “IEEE Guide for Safety in AC Substation Grounding”, The IEEE Standards Association, New York, 2000.
|
[2]
|
S. Visacro, “A Comprehensive Approach to the Grounding Response to Lightning Currents,” IEEE Transactions on Power Delivery, Vol. 22, No. 1, 2007, pp. 381-386.
doi:10.1109/TPWRD.2006.876707
|
[3]
|
L. Grcev and F. Dawalibi, “An Electromagnetic Model for Transients in Grounding Systems,” IEEE Transactions on Power Delivery, Vol. 5, No. 4, 1990, pp. 1773-1781.
doi:10.1109/61.103673
|
[4]
|
Y. Liu, N. Theethayi and R. Thottappillil, “An Engineering Model for Transient Analysis of Grounding System Under Lightning Strikes: Nonuniform Transmission-Line Approach,” IEEE Transactions on Power Delivery, Vol. 20, No. 2, 2005, pp. 722-730.
doi:10.1109/TPWRD.2004.843437
|
[5]
|
A. F. Otero, J. Cidrás and J. L. del álamo, “FrequencyDependent Grounding System Calculation by Means of a Conventional Nodal Analysis Technique,”, IEEE Transactions on Power Delivery, Vol. 14, No. 3, 1999, pp. 873878. doi:10.1109/61.772327
|
[6]
|
C. M. Portela, “Measurement and Modeling of Soil Electromagnetic Behavior,” Proceedings of IEEE International Symposium on Electromagnetic Compatibility, Seattle, 2-6, August 1999, pp. 1004-1009.
|
[7]
|
C. M. Portela, M. C Tavares and J. Pissolato, “Accurate Representation of Soil Behaviour for Transient Studies,” IEEE Proceedings Generation, Transmission and Distribution, Vol. 150, No. 6, 2003, pp. 736-744.
|
[8]
|
C. M. Portela, J. B. Gertrudes, M. C. Tavares and J. Pissolato, “Earth Conductivity and Permittivity Data Measurements: Influence in Transmission Line Transient Performance,” Elsevier, Electric Power Systems Research, Vol. 76, No. 11 2006, pp. 907-915.
doi:10.1016/j.epsr.2005.11.006
|
[9]
|
A. C. S. Lima and C. M. Portela, “Inclusion of FrequencyDependent Soil Parameters in Transmission-Line Modeling,” IEEE Transactions on Power Delivery, Vol. 22, No. 1, 2007, pp. 492-499. doi:10.1109/TPWRD.2006.881582
|
[10]
|
C. L. Longmire and K. S. Smith, “A Universal Impedance for Soils,” Defense Nuclear Agency, Washington, DC, 1975.
|
[11]
|
J. H. Scott, “Electrical and Magnetic Proprieties of Rock and Soil,” United States Department of the Interior Geological Survey, 1983.
|
[12]
|
S. Visacro and R. S. Alípio, “Frequency Dependence of Soil Parameters: Experimental Results, Predicting Formula and Influence on the Lightning Response of Grounding Electrodes,” IEEE Transactions on Power Delivery, Vol. 27, No. 2, 2012, pp. 927-935.
doi:10.1109/TPWRD.2011.2179070
|
[13]
|
R. S. Alípio, M. A. O. Schroeder, M. M. Afonso, T. A. S. Oliveira and S. C. Assis, “Electric Fields of Grounding Electrodes with Frequency Dependent Soil Parameters,” Electric Power Systems Research, Vol. 83, No. 1, 2012, pp. 220-226. doi:10.1016/j.epsr.2011.11.011
|
[14]
|
L. Grcev, “Impulse Efficiency of Ground Electrodes,” IEEE Transactions on Power Delivery, Vol. 24, No. 1, 2009, pp. 441-451. doi:10.1109/TPWRD.2008.923396
|
[15]
|
S. Visacro and C. M. Portela, “Soil Permittivity and Conductivity Behavior on Frequency Range of Transient Phenomena in Electric Power Systems,” Proceedings of Symposium High Voltage Engineering, Braunschweig, 24-28 August 1987, pp. 107-112.
|
[16]
|
S. Visacro and A. Soares, “HEM: A Model for Simulation of Lightning-Related Engineering Problems,” IEEE Transactions on Power Delivery, Vol. 20, No. 2, 2005, pp. 12061208. doi:10.1109/TPWRD.2004.839743
|
[17]
|
A. Soares, M. A. O. Schroeder and S. Visacro, “Transient Voltages in Transmission Lines Caused by Direct Lightning Strikes,” IEEE Transactions on Power Delivery, Vol. 20, No. 2, 2005, pp. 1447-1452.
doi:10.1109/TPWRD.2004.839214
|
[18]
|
F. H. Silveira and S. Visacro, “The Influence of Attachment Height on Lightning-Induced Voltages,” IEEE Transactions on Electromagnetic Compatibility, Vol. 50, No. 3, 2008, pp.743-747. doi:10.1109/TEMC.2008.926885
|
[19]
|
R. S. Alípio, M. A. O. Schroeder, M. M. Afonso and T. A. S. Oliveira, “Electromagnetic Fields of Buried Conductors,” Proceedings of the International Conference on Grounding Earthing, Florianópolis, 11-15 November 2008, pp. 399-402.
|
[20]
|
R. F. Harrington, “Field Computation by Moment Methods,” IEEE Press, New York, 1993.
doi:10.1109/9780470544631
|
[21]
|
T. Takashima, T. Nakae and R. Ishibashi, “Calculation of Complex Fields in Conducting Media,” IEEE Transactions on Electrical Insulation, Vol. EI-15, No. 1, 1980, pp. 1-7. doi:10.1109/TEI.1980.298290
|