Development of Ultra Fast Liquid Chromatography (UFLC) Method for Fluorescence Detection of Domperidone in Human Serum and Application to Pharmacokinetic Study ()
Received 19 November 2015; accepted 15 January 2016; published 19 January 2016

1. Introduction
Domperidone (
DOM
) is a dopamine-receptor (D2) antagonist. Chemically, 5-chloro-1-[1-[3-(2-oxo-2,3-dihydro- 1H-benzimidazol-11-yl)propyl]-piperidin-4-yl]-1,3-dihydro-2H-benzimidazol-2-one and Propranolol HCl (PH) is 1-naphthalen-1-yloxy-3-(propan-2-ylamino) propan-2-ol; hydrochloride. It is widely used in the treatment of motion-sickness, increasing lower esophageal sphincter pressure, further preventing nausea and vomiting and also prompting gastrointestinal motility [1] . In humans, peak plasma levels of domperidone occur within 10 to 30 min following intra muscular injection and 30 min after oral (fasted) administration. It was reported to be rapidly absorbed after oral administration, but undergone extensive first pass metabolism, leading to poor bioavailability of 15% [2] .
An accurate measurement of low concentrations of DOM in serum method is necessary for pharmacokinetic studies. Literature survey reveals that several simultaneous methods have been used for quantification of DOM using high-performance liquid chromatography (HPLC) in tablet formulation [3] -[7] ; in rat serum samples using HPLC with fluorescence detection [8] , in human serum and human breast milk by electrospray mass spectrometry and by fluorescence detector [9] [10] and 14C-labelled radio activity method for excretion and metabolism in animals and men [11] . Previously, liquid chromatography tandem mass spectrometry chromatographic method in human plasma [12] [13] and spectroscopic study for conformational analysis [14] was reported. The drug metabolites in plasma have been determined by LC-
ESI
-MS/MS in human plasma and urine samples of gastroparesis patients [15] . Among the available various methods, the HPLC method seems convenient, reliable, and reproducible and as minimal sample preparation required.
The content of the present work was to develop and optimize a simple ultra fast liquid chromatography (UFLC) method with fluorescence detection for the determination of DOM in human serum was developed. For the evaluation of new drug delivery systems like buccal drug delivery systems, conducting of pharmacokinetic studies in human volunteers is essential for approval to marketing after preclinical evaluation in animal models. The advantages of present method include simple and single step extraction procedure using inexpensive chemicals, and short run time. The present method was also successfully applied for the study of pharmacokinetics of DOM from bioadhesive buccal patches in humans. The chemical structure of domperidone and propranolol hydrochloride as an internal standard is shown in Figure 1.
2. Experimental
2.1. Materials
Domperidone (
DOM
) and propranolol hydrochloride (PH) pure samples were gifted respectively by Torrent pharmaceuticals, Baroda, India. Acetonitrile, methanol (HPLC) and potassium dihydrogen orthophosphate, ortho phosphoric acid (GR) and sodium hydroxide were purchased from Merck, Mumbai, India. Double distilled water was used during the entire HPLC procedure.
2.2. Chromatographic Conditions
Analysis of samples was performed using UFLC. The UFLC system (Shimadzu, Kyoto, Japan) consisted of two LC-20AD Prominence liquid chromatograph pumps, RF-10
AXL
, Fluorescence detector, CTO-20AC Prominence column oven with Lab solutions (LC solutions) software. The analytical column used was Onyx monolithic C18 column (Phenomenex, 100 mm2 4.6 mm i.d, particle size 5 µ) at 25˚C temperature. The mobile phase
![]()
Figure 1. Structures of domperidone (a) and propranalol hydrochloride (b).
used was a mixture of (62:38) of 10 mM phosphate buffer pH adjusted to 3.1 with OPA and methanol. The flow rate was 1 mL∙min−1 and detection was carried out at excitation 282 and emission 328 nm. The injection volume was 20 μL and detector sensitivity was set to 0.0005 AUFS.
2.3. Preparation of Calibration Standards and Quality Control (QC) Samples
Initially, the stock solutions of DOM and PH were prepared in methanol at a concentration of 100 μg∙mL−1 each. PH (Figure 1(b)) was used as an internal standard (IS). The working solutions of 10 ng∙mL−1 to 10 μg∙mL−1 for DOM and 1.5 μg∙mL−1 for PH were prepared by appropriately diluting the respective stock solutions. DOM working solutions were used to prepare the spiking stock solutions for construction of calibration curve at a concentration of 10 - 10,000 ng∙mL−1. QC samples at three different levels for DOM (15, 4750 and 9500 ng∙mL−1) were prepared. All the stock solutions were refrigerated (4˚C) when not in use. Calibration standards and QC samples were prepared in bulk by spiking 100 μL of respective spiking stock solutions to 1 mL of control human serum and were stored at −20˚C until analysis.
2.4. Sample Preparation for Analysis
Aliquot (1 mL) of human serum containing DOM was transferred into screw capped tubes and 100 μL of an IS (1500 ng∙mL−1 of PH) was added and vortexed for 2 min. Acetonitrile 7 mL was added, vortexed for 2 min. This was centrifuged at 6000 rpm for 15 min. The organic layer was separated and allowed to evaporate in vacuum oven (Sheldon Manufacturing Inc., Cornelius, USA). The evaporated residue was reconstituted with 100 µL of mobile phase and 20 μL of the reconstituted sample was injected into HPLC system.
2.5. Assay Validation
The intra-day and inter-day precision and accuracy of the assay was determined by percent coefficient of variation (CV) and percent relative error (RE) values respectively, based on reported guidelines [16] . Samples containing 15, 4750 and 9500 mL−1 of DOM were spiked for the determination of precision and accuracy. Five replicates at each concentration were processed as described above on days 1, 3, 5 and 10 to determine intra-day and inter-day precision and accuracy. The percent CV and percent RE values were calculated using following equations:
Percent CV = (SD/mean) × 100
Percent RE = [(Measured value − True value)/True value] × 100
2.6. Low Limit of Quantitation (LLOQ) and Limit of Detection (
LOD
)
The lowest concentration of analyte that can be determined with precision and accuracy of acceptable range is expressed as LLOQ. Parameter that provides the lowest concentration in a sample that can be detected from background noise but not quantitated is the LOD of a molecule. LOD was determined using signal-to-noise ratio (s/n) of 3:1 by comparing test results from samples with known concentrations of analytes with blank samples.
2.7. Recovery
The recovery of DOM was determined for QC samples at concentration of 15, 4750 and 9500 mL−1. Five replicates of each QC sample were extracted and injected into UFLC system. The extraction recovery at each concentration was calculated using following equation:
Recovery = (Peak area after extraction/Peak area after direct injection) × 100
2.8. Stability Studies
To ensure the reliability of results in handling and storing of serum samples and stock solutions, stability studies were carried out at three concentration levels of DOM, 15, 4750 and 9500 mL−1. The stability of spiked human serum stored at room temperature (bench top stability) was evaluated for 12 h. Freeze and thaw stability was performed over three freeze-thaw cycles by thawing at room temperature for 2 - 8 h and then refreezing at −20˚C for 12 - 24 h. The long-term stability of DOM in human serum was assessed by carrying out the experiment after 30 days of storage at −20˚C. The stock solution stability of DOM (100 μg∙mL−1 for each) was determined at room temperature for 12 h and upon refrigeration (4˚C) for 14 days. The concentration of DOM after each storage period was related to the initial concentration as determined for the samples that were freshly prepared.
2.9. Robustness
To determine the robustness of the method, the final experimental conditions were altered and the results were examined. The flow rate was varied by 1 ± 0.2 mL∙min−1. The percentage of organic strength was varied by 62% ± 2%. Buffer concentration was varied by 10 ± 5 mM, pH varied by 3.1 ± 0.2 units and column temperature was varied by 40˚C ± 5˚C.
2.10. Application to Pharmacokinetic Study
The pharmacokinetic study was conducted in twelve healthy male volunteers. The study protocol was reviewed and approved by the institutional human ethical committee, University College of Pharmaceutical Sciences, Kakatiya University, Warangal, India. The bioadhesive hot melt extruded immediate release and controlled release buccal Patches (HME IR and HME CR) was compared with marketed tablet (Domstal). The volunteers participated in the study were non-alcoholic and had no medication for two weeks prior to the study. Volunteers were allowed free access to food and water, until the night prior to dosing and were fasted for 10 h.
Latin square cross over design was followed; Volunteers were divided into two groups, each group consisting of six volunteers. To one group, marketed tablet was administered and bioadhesive HME buccal patches to another group in first phase. In second phase vice versa was followed and was conducted after 2 weeks of wash out period. Blood samples (5 mL) were collected at preset time intervals of 0, 0.25, 0.5, 1, 1.5, 2, 4, 8, 12 and 24 for HME IR patch and 0.5, 1, 1.5, 2, 4, 6, 8, 12 and 24 for HME CR patch. All blood samples were allowed to clot and centrifuged for 10 min at 5000 rpm (MIKRO 220R, Hettich, Germany). The serum was separated and transferred into clean micro-centrifuge tubes and stored at −20˚C until UFLC analysis. The amount of DOM in the samples was estimated using UFLC.
Pharmacokinetic parameters, peak serum concentration (Cmax), time to reach peak concentration (Tmax) and area under the curve (AUC) for DOM was obtained for each volunteer using a computer program KINETICA 2000 (Version 3.0, Innaphase Corporation, Philadelphia, USA) meant for calculation of model independent parameters.
3. Results and Discussion
3.1. Chromatography
The chromatographic conditions and sample preparation for the proposed method were optimized to suit the pharmacokinetic studies. Figure 2 shows typical chromatograms of human blank serum (drug free), serum
(a)
(b)
(c)
Figure 2. Representative chromatograms of human blank serum (a), drug spiked with serum (b) and drug and internal standard spiked with serum after administration of buccal patch (c).
spiked with DOM; human serum after buccal administration of DOM HME patches dosage form. The retention times of DOM and PH respectively were found to be 6.36 and 7.94 minutes respectively with a total run time of 10 min. The analytical process of DOM and IS were resolved with good symmetry. At the retention times of drug and IS, no endogenous interfering peaks were observed in individual human blank serum, hence, thereby confirming the specificity of the analytical method. System suitability parameters for the method were as follows: theoretical plates for DOM and IS were 1684 and 1821 respectively. Tailing factor were 1.2 and 1.5 respectively for DOM and PH. Resolution between DOM and IS was 2.4.
3.2. Quantification and Calibration Curve
For the quantification of DOM in human serum, the ratio of peak area of DOM to IS was used. The calibration curves of DOM was constructed over a period of 10 - 12 days, each time the calibration curve originating from a new set of extractions. Linear relationship was observed between the concentration of DOM and the peak area of DOM with a correlation coefficient (r2 = 0.999). The regression equation is y = mx + c, where y represents the peak area ratio of DOM to IS, x represents the concentrations of DOM, m is slope of the curve and c is the intercept.
3.3. Accuracy and Precision
The required studies were carried out to estimate the precision and accuracy of the UFLC method. The accuracy and precision of the method were evaluated for DOM analytes with QC samples at concentrations of 15, 4750 and 9500 ng∙mL−1. The inter-day accuracy and precision were determined on four different days and the results are shown in Table 1. The inter-day and intra-day precisions of the QC samples for DOM were satisfactory with CV and % RE was found to be less than 5% and 3.5%, respectively.
3.4. LLOQ and LOD
LLOQ was established by determining the concentrations of four spiked calibration standards. The LLOQ of the method was found to be 0.25 ng∙mL−1 with CV less than 10% and an accuracy of 93% - 100%. The LOD was determined to be 0.50 ng∙mL−1 for DOM based on a signal to noise (s/n) ratio of 2:1.
3.5. Recovery
The extraction recovery was determined by standard addition at three different concentrations 15, 4750, 9500 ng∙mL−1, one concentration (1500 ng∙mL−1) for IS. The extraction recovery was calculated by comparing the peak areas of the prepared standard samples with those of standard solutions; the results are shown in Table 2. The extraction recovery of DOM at 15, 4750 and 9500 ng∙mL−1 was 98.5%, 98.3% and 98.3%. The mean recovery of PH was found to be 97.3%. The recovery of DOM from the human serum samples was consistent and efficient with using the above described procedure.
3.6. Stability
The stability of stock solutions was performed at 1000 ng∙mL−1 of DOM. After storage for 14 days at 4˚C and at room temperature for 12 h, more than 99% of DOM remained unchanged, based on peak areas in comparison with freshly prepared solution. The results suggest that DOM in stock solutions were stable for at least 14 days when stored at 4˚C and for 12 h at room temperature. Bench top stability of DOM in serum was investigated and
![]()
Table 1. Intra-day and inter-day precision and accuracy data for assay of DOM in human serum (n = 6).
the results revealed that DOM in serum were stable with an average percentage of 97.8, 98.9, 100.2. The repeated freezing and thawing for three cycles of serum samples spiked with DOM, showed a mean percentage concentration of 96, 99 and 100. Long-term stability of the DOM in serum at −20˚C showed a mean percentage concentration of 95, 98.8, and 99.6. The results (Table 3) of stability study indicated that DOM was stable in the studied conditions.
3.7. Robustness
The results of robustness study are shown in Table 4. It can be seen that every employed condition, the chromatographic parameters are in accordance with established value [16] . In all the employed conditions, the tailing factor for DOM and PH was found to be less than 1.4 and all analytes were well separated under the changes carried out. The resolution ranged between DOM and IS was 2.9 - 3.8. Considering the result of modifications in the system suitability parameters and the specificity of the method, it would be concluded that the method conditions are robust.
3.8. Application to Pharmacokinetic Study
The method was applied to the analysis of serum samples obtained after buccal administration of a hot melt extruded immediate and controlled release buccal patches in healthy human volunteers. Figure 3(a), Figure 3(b) depicts the mean serum profiles of DOM after administration of buccal route. The pharmacokinetic parameters estimated were shown in Table 5. The Cmax, Tmax, AUC0-24 and AUCTotal for DOM after administration of IR and CR buccal patch were found to be 129.7 ng∙mL−1, 1.5 h, 455.1 ng∙h∙mL−1 and 145.7 ng∙mL−1, 5.25 h, 911.0 ng∙h∙mL−1 respectively.
![]()
Table 2. Recovery and accuracy of the proposed method.
![]()
Table 3. Stability study results of the proposed method.
aAfter 12 hr at room temperature; bAfter three freeze thaw cycles; cAfter 30 days at −20˚C; d Values are mean ± S.D (n = 3).
![]()
Table 4. Robustness data of the developed HPLC method.
![]()
(a) (b)
Figure 3. Mean serum concentration vs time profiles of domperidone after HME immediate and controlled release buccal patches compared to marketed tablet (mean ± SD, n = 6).
![]()
Table 5. Pharmacokinetic parameters of HME immediate and controlled release DOM buccal patches after buccal administration to human volunteers (mean ± SD, n = 6).
4. Conclusion
A simple, sensitive and reliable method for the fluorescence determination of domperidone over the concentration range of 10 - 10,000 ng∙mL−1, in human serum by UFLC was developed and validated. The method consisted of sample preparation by protein precipitation and extraction into acetonitrile, followed by chromatographic separation and fluorescence detection. No interfering peaks were observed at the elution times of domperidone and IS. The method was accurate, reproducible, specific and applicable to the evaluation of pharmacokinetic profiles of domperidone in humans.