Article citationsMore>>
Ozaki, Y., Yamaguchi, T., Suzuki, T., Nakamura, M., Kitayama, M., Nishikawa, H., Inoue, T., Hara, K., Usuba, F., Sakurada, M., Awano, K., Matsuo, H., Ishiwata, S., Yasukawa, T., and Ismail, T.F., Hishida, H. and Kato, O. (2007) Impact of cutting balloon angioplasty (CBA) prior to bare metal stenting on restenosis. Circulation Journal, 71, 1-8. doi:10.1253/circj.71.1
has been cited by the following article:
-
TITLE:
Comparison of pre-dilation with a non-compliant balloon versus a dual wire scoring balloon for coronary stenting
AUTHORS:
Kenji Sadamatsu, Keiki Yoshida, Yuya Yoshidomi, Yasuaki Koga, Kaori Amari, Tomotake Tokunou
KEYWORDS:
Intravascular Ultrasound; Stent; Coronary Artery Disease; Restenosis; Angioplasty
JOURNAL NAME:
World Journal of Cardiovascular Diseases,
Vol.3 No.6,
August
26,
2013
ABSTRACT: Purpose: The aim of this study was to determine the influence of lesion preparation using the dual wire scoring balloon on stent expansion and long-term outcomes. Methods: Forty-six consecutive de novo lesions treated with a single >2.5 mm drug-eluting stent under intravascular ultrasound guidance, using two implantation strategies, were randomly assigned to: 1) pre-dilation with a non-compliant balloon (NC group; n = 23) or 2) pre-dilation with a dual wire scoring balloon (DS group; n = 23). Results: Although the balloon size and the maximal dilation pressure for pre-dilatation was larger (3.33 ± 0.28 vs 3.09 ± 0.33 mm, p = 0.01) and higher (11.6 ± 3.2 vs 8.6 ± 2.7 atm, p
Related Articles:
-
Laurence Stephenson
-
Daoling Fu, Ming Yang, Jindong Chang
-
Valerii Ermakov, Volodymyr Kolomoets, Leonid Panasyuk, Baja Orasgulyev
-
Andrew Beckwith
-
Sopita Khamrod