Micronization of Cetirizine Using Rapid Expansion of Supercritical Carbon Dioxide ()
Subject Areas: Chemical Engineering & Technology, Drugs & Devices, Nanometer Materials

1. Introduction
In the science of drug and pharmaceutical production, high solubility rate of the drug powders is an essential parameter helping the pharmaceutical developers toward more effective products. Unfortunately, there are many kinds of drugs exhibiting poor solubility in water and gastronical fluids bounding their application. Poorly water-soluble drug candidates often merge from contemporary drug discovery programs, and present formulators with considerable technical challenges [1] . In more details, many newly proposed and produced drugs suffer from poor water solubility, consequently leading to major hurdles in the design of suitable formulations for administration to patients. Regarding this shortcoming, the development of techniques and materials to overcome these hurdles is a major area of research in pharmaceutical companies.
One of the proposed techniques to overcome this problem is reducing the particle size of the particles. In more details, it has been proven that dissolution rate is a function of the surface area of the particles. On the other hand, solubility, is a direct function of total surface area for a dispersed phase, and is inversely related to particle size according to the expression, Sv = 6/d, where Sv is the specific surface area and d is the average particle diameter [2] . Based on this fact, if the size of the particle reduces, the solubility will increase.
In the way of reducing particle size, several techniques have been reported that the common technique for the preparation of micron-size drugs is the mechanical comminution (e.g., by crushing, grinding, and milling) of previously formed larger particles. Although, these techniques are successful in some extend, they introduce several drawbacks (e.g. high amount of energy and alteration of drug substance properties and surface properties in a mainly uncontrolled manner) [3] .
In this way, during the past two decades, the researchers were seeking for methods which produce drug particles in micron- or nano-levels (with narrow particle size distribution), and the drug particles experience no changes in their physicochemical properties. One of the successful methods for producing high-quality drug powders with narrow particle size distribution is supercritical fluid (SCF) based technologies [4] - [10] . This high capability rises from the unique advantages of the supercritical fluids which are good diffusivity of gases and good solubility of liquids. It is possible to develop products of standardized concentration of active ingredients, or produce pharmaceutical products of much higher concentration [11] . Among the different possible solvents, carbon dioxide (CO2) is one of the most widely used solvents since it introduces unique properties including being environmentally-friendly, non-toxic, inflammable, cheap and highly available. Generally there are two common supercritical fluid based technologies for producing micron- or nano-size particles of drug powders including rapid expansion of supercritical solution (RESS) [5] [12] - [19] . There are two major branches in this technology: 1) rapid expansion of supercritical solution and 2) GAS technique and its branches [20] . The RESS process is consisted of two different sections including extraction and precipitation units. In the first section, the solutes are dissolved in a SCF. After loading the supercritical fluid with the solute, an extremely fast phase change from the supercritical to the gas-like state takes places during the expansion in the supersonic free-jet. This leads to high super-saturation (about 109) and formation of fine particles, and consequently solubility and bioavailability of the drug will enhance due to particle size reduction [11] [21] [22] . In the RESS method there are different operational conditions that can be manipulated to engineer particle based on the requirements. Among these operational conditions, the most effective parameters are extraction pressure; extraction temperature, expansion chamber characterization, co-solvent, concentration of solute and nozzle configuration will influence the particle size and morphology of the manufactured particles [23] .
Although all the parameters are important to obtain the best results, nozzle and its characterization have a critical role in the RESS process. In many studies, capillary nozzles or laser-drilled nozzles were applied to manufacture micron- and submicron-level particles [24] - [26] . Based on some studies, it was considered that smaller nozzle in diameter will cause fine or ultra-fine particles [27] [28] . Usually, the diameters of the used nozzle are about 40 - 200 μm, because producing smaller laser-drilled nozzle is not easy [29] .
Since the production of laser drilled nozzles is costly and needs unique technologies, a new kind of nozzle was designed and constructed by the coauthors whose applicability and functionality were established previously [29] - [39] .
In this way, since there is no report about the micronization of the cetirizine particles using RESS methods based on the best knowledge of the authors, in the current investigation cetirizine is selected as the model drug. For this purpose, several operational parameters including extraction pressure (160 - 220 bar), temperature (308 - 328 K), nozzle length (2 - 11 mm) and diameter (450 - 1700 μm) are examined to find if RESS process is feasible to fabricate micron- or submicron-level particles in size. Cetirizine is a non-sedating antihistamine with molecular weight of 388.888 g∙gmol−1 which works similarly to the other second generation antihistamines, loratadine (Claritin), fexofenadine (Allegra) and azelastine (Astelin). Histamine is a chemical that is responsible for many of the signs and symptoms of allergic reactions, for example, swelling of the lining of the nose, sneezing, and itchy eyes.
2. Experimental Procedure
2.1. RESS Apparatus
The RESS experiments were performed using a homemade apparatus rated for maximum operating temperature and pressure of 353 K and 400 bar, respectively (see Figure 1). A brief description of the used apparatus is as follow; at first, the gaseous CO2 supplied from a cylinder capsule was passed through a filter and then was liquefied using a refrigerator. After liquefaction, it was pumped by a reciprocating oil-free water-free high pressure manual pump (Haskel, USA) into a vertical surge tank. The surge tank was used to dampen the pressure fluctuations produced by operation of the manual pump. The surge tank was equipped with a bourdon gauge in the range of 0 - 400 bar by a division of 1 bar which gives the operator the ability of easy controlling of the pressure during the experiments.
The pressurized CO2 then entered into an extraction vessel (180 ml) fulfilled with a basket including the powder of cetirizine packed with glass beads for preventing channeling phenomenon. In more details, a specific amount of cetirizine powder was mixed with glass beads to enhance the contact surface between the cetirizine powder and supercritical carbon dioxide enhances the solubility of cetirizine in supercrtic.al and preventing channeling of high-pressure carbon dioxide through the bed. The temperature of the surge tank and equilibrium vessel were controlled using a hot water jacket surrounded these sections. In addition, the temperature of the system was sensed by a PT-100 thermocouple control the temperature using PID controlling protocol with accuracy of 0.1˚C. The noteworthy point is that the outlet port of the equilibrium cell was covered by glass wool to ensure that during the expansion of the supercritical solution through the nozzle no undissolved drug particles will carry over the SC-CO2 flow. After preparing the basket containing the drug powder and glass bead, it was then placed into an extraction vessel and was held in the desired conditions for about 3 h to ensure that complete equilibrium has been obtained. After that, the equilibrated solution was then expanded by a pre-heated fine needle valve into a nozzle. The fine needle valve was pre-heated to compensate the heat loss because of the Joule Thomson effect and to prevent the nozzle clogging during the expansion. The precipitated particles were collected on the stubs and analyzed by a SEM to monitor the particle size and morphology.
![]()
Figure 1. The schematic of the used apparatus.
2.2. Materials
Cetirizine was kindly supplied from Alma Concept Company (France), and used as received. In addition, the CO2 (99.9% < purity) was supplied from Abughadareh Gas Chemical Company, Iran. The mean particle size of the original cetirizine was about 98.52 μm, respectively (see Figure 2, Table 1).
2.3. Particle Size and Morphology
The morphology and size of the precipitated particles were examined using scanning electron microscopy (SEM) (S360-CAMBRIDGE). In brief, prior to examine the samples by a SEM the precipitated cetirizine particles were collected on the conductive stubs which were then coated by a sputter-coater (SC-7640-Polaron) with Pd-Pt in the presence of argon (99.9% < purity) at room temperature for a period of 100 s under an accelerating voltage of 20 kV. The mean particle size of the precipitated particles was calculated by counting about 100 particles, arbitrarily selected. The mean particle size was calculated by a written program which randomly selected 100 particles of the SEM images.
2.4. Nozzle Configuration
The structure of the new nozzle is illustrated in Figure 3. The nozzle comprises two parts, shell part and inside part. In this design, the clearance between the inside part and the nozzle acts as a circular orifice so that supercritical fluids can spray from a narrow exit in a few microns.
Also the swirled channel enhances the chance of the formation of spherical form particles which could be helpful to improve the morphology of particles. In the entrance of the nozzle, SC-CO2 is introduced through the spiral channel, so the fluids can be swirled out of the nozzle. In this kind of nozzle instead of the usual diameter, the effective nozzle diameter has been defined as follows:

where SEffective = SShell − SInside. The calculated effective diameters for the experiments are given in Table 2.
3. Results and Discussions
In the current investigation, 12 different experiments were performed to find the effect of different operational parameters including extraction pressure (160 - 220 bar), extraction temperature (308 - 328 K), nozzle length (2 - 11 mm) and nozzle diameter (450 - 1700 μm).
![]()
Figure 2. The SEM image of intact particles of cetirizine.
![]()
Figure 3. Schematic diagram of the used nozzle: (a) side view and (b) front view.
![]()
Table 1. The physicochemical properties of the cetirizine [40] .
aThese properties are estimated using Joback method (Ref. [41] ); bThe acentric factor was estimated using Ref. [41] .
![]()
Table 2. Calculated effective nozzle diameters.
3.1. Effect of Extraction Pressure
In the first stage of this investigation, the effect of extraction pressure in the range of 160 bar to 220 bar on the size and morphology of the cetirizine particles were investigated while the other operating conditions including extraction temperature (318 K), nozzle length (5 mm) and nozzle diameter (1700 μm) were kept constant. The obtained results revealed that as the pressure increases from 160 bar to 220 bar, the mean particle size of the precipitated cetirizine particles reduces from 12.68 μm to 7.60 μm. This observed trend can be described based on the solubility of cetirizine in the supercritical carbon dioxide (see Figure 4). In more details, Hezave et al. [40] has been reported that the molar solubility of cetirizine in the supercritical carbon dioxide increases from 3.62 × 10−5 to 2.15 × 10−4 as the pressure increases from 160 bar to 240 bar for isothermal of 318 K. They have
![]()
Figure 4. Effect of extraction pressure on the mean particle size of the precipitated particles, (a) Pext = 220 bar and (b) Pext = 160 bar (Text = 318 K, Lnozzle = 5 mm and Dnozzle = 1700 μm).
been reported that an increase in the operating pressure from 160 to 400 bar at all the isotherms resulted in an increase in cetirizine solubility. This observed trend was related to this fact that as the pressure increases the intermolecular space between the CO2 molecules reduces consequently increases the density of supercritical carbon dioxide and interactions between the cetirizine and CO2 molecules. As results the solubility of cetirizine in the supercritical carbon dioxide enhances consequently results higher super-saturations in the fluid upon expansion. According to classical theory of nucleation, higher super-saturation leads higher nucleation rate and the particle volume is inversely proportional to the nucleation rate; our above results appear to agree with simple theoretical predictions [42] . Similar results were obtained by Liu and Nagahama [43] , Wang et al. [44] , Huang et al. [42] , Yildiz et al. [45] and our previous works [20] [21] for naphthalene, titanocene Dichloride, aspirin, salicylic acid, mefenamic acid and ketoprofen, respectively. However, Reverchon et al. [46] obtained an opposite result for the effect of extraction pressure on salicylic acid particles. The difference in results may be explained by different experimental conditions or nozzle configuration.
3.2. Effect of Temperature
In the second stage of this study, the effect of extraction temperature in the intervals of 308, 318 and 328 K was investigated while the other operational conditions including extraction pressure (220 bar), nozzle length (5 mm) and nozzle diameter (1700 μm) were kept constant during the experiments. The obtained results demonstrated that there no clear trend for the effect of extraction temperature on the particle size of precipitated particles was observed. By the way, in the previous study [40] the authors have found that cetirizine + SC-CO2 experiences a cross over pressure about 200 bar. In more details, the solubility of cetirizine decreases as the temperature increases for pressures lower than 200 bar while for higher pressures, an increase in the temperature leading to an increase in the solubility of cetirizine. Based on these findings, it seems that since the examined extraction pressure was about 220 bar which is not so far from the cross over pressure, no obvious trend was observed for the effect of extraction temperature. But the point is worth mentioning is that the morphology of the precipitated particle are somehow move toward more spherical shape compared to the intact particles of the cetirizine (see Figure 5). Finally, since no obvious trend on the effect of extraction temperature was observed, the extraction temperature for rest of the experiments were held at 318 K since smaller parties were precipitated using this value.
![]()
Figure 5. Morphology shifting of the precipitated particles of cetirizine toward more regular form (somehow spherical form) (Pext = 220 bar, Text = 308 K, Lnozzle = 5 mm and Dnozzle = 1700 μm).
3.3. Effect of Nozzle Length
In the third series of experiments, the effect of nozzle length on the mean particle size of the precipitated particles was investigated ranging it between 2 - 11 mm while the other operational conditions were held constant as demonstrated in Table 1. The obtained results demonstrated that as the nozzle length increases larger particle in size are precipitated. In more details, investigation on Table 3 shows that an increase in nozzle length will cause an increase in the mean particle size of the precipitated particles (see Figure 6). When the capillary length is increased, the precipitation starts inside the capillary, so the particle size of the precipitated particles in long nozzle was bigger than that in the short one [47] .
Similarly, Wang et al. [44] and Yildiz et al. [45] , Hezave et al. [32] [35] reported an increase in the mean particle size of the precipitated particles of titanocene dichloride, salicylic acid and mefenamic acid, ibuprofen and ketoprofen by increasing the nozzle length. They related the increase of mean particle size by increasing the nozzle length to this fact that, when the length of the capillary is smaller, pressure reduction starts earlier in the expansion device, even in the upstream of the capillary. On the other hand, as the pressure reduction starts earlier, more gradual decrease of the pressure is expected instead of a more rapid expansion in the shorter capillary compared to the longer one. In contrast to the obtained results in the current investigation and those reported in the previously published literature, Kayrak et al. [47] and Hezave et al. [30] reported a contradicting results for micronization of ibuprofen and diclofenac. They have been described this contradicting results as follow. A reduction in the length of the capillary causes earlier pressure reduction in the expansion device, even in the up- stream of the capillary. Due to earlier start in pressure reduction, more gradual decrease of the pressure is expected rather than in a shorter capillary. The noteworthy point is that as can be seen in Figure 7 it is completely obvious that as the nozzle length increases, the risk of precipitated particle for agglomeration increases consequently may lead to particles with bigger size. In addition, it can be concluded from the SEM images that the
![]()
Table 3. The effect of different operational parameters on the mean particle size of the precipitated particles of cetirizine.
![]()
Figure 6. Effect of nozzle length on the particle size distribution of the precipitated particles of cetirizine during RESS process, (a) 2 mm, (b) 5 mm, (c) 8 mm and 11 mm (Pext = 220 bar, Text = 308 K and Dnozzle = 1000 μm).
![]()
Figure 7. Agglomerated particles of the precipitated cetirizine particles (Pext = 220 bar, Text = 308 K, Lnozzle = 2 mm and Dnozzle = 1000 μm).
precipitated particles of the cetirizine experienced narrow particle size distribution with more spherical shape morphology (see Figure 8).
3.4. Effect of Nozzle Diameter
At the last series of experiments, the effect of nozzle diameter on the size of the cetirizine particles was investigated by ranging this parameter between 450 μm to 1700 μm. The obtained results revealed that increasing the nozzle diameter from 450 μm to 1700 μm leads to an increase in the mean particle size of the precipitated particles from 0.52 μm to 5.15 μm (see Figure 9). In addition, a closer examination in the image analysis of the obtained results it can be concluded that, a reduction in nozzle diameter not only leading to a reduction in particle size but also leading to a narrow particle size distribution compared with the larger nozzle diameter (see Figure 10).
Finally, examining the SEM images not only revealed that particle size distribution of the precipitated cetirizine particles become narrower but also the particles move toward more spherical morphology (see Figure 11).
![]()
Figure 8. Spherical shape morphology and narrow particle size distribution of the precipitated particles of cetirizine (Pext = 220 bar, Text = 308 K, Lnozzle = 2 mm and Dnozzle = 1000 μm).
![]()
Figure 9. Effect of effective nozzle diameter on the mean particle size of the precipitated particles of cetirizine.
![]()
Figure 10. The effect of effective nozzle diameter on the particle size distribution of the precipitated particles of the cetirizine, (a) 450 μm, (b) 650 μm, (c) 1000 μm and (d) 1700 μm (Pext = 220 bar, Text = 308 K and Lnozzle = 5 mm).
![]()
Figure 11. Effect of nozzle diameter on the morphology and uniformity of the precipitated particles (Pext = 220 bar, Text = 308 K and Lnozzle = 5 mm and Dnozzle = 450 μm).
4. Conclusion
In the current study, the efficiency and applicability of RESS process for producing micro-size particles of cetirizine were investigated. For this purpose, a systematic series of experiments was performed to find the optimum operational conditions of extraction pressure and temperature, nozzle length and nozzle diameter leading to producing the micron-size particles of cetirizine while carbon dioxide was selected as the supercritical fluid. The obtained results demonstrated that an increase in the extraction pressure leads to a reduction in the particle size, while for other three parameters including nozzle length, extraction temperature and nozzle diameter, an increase leads to an increase in the size of precipitated particles. Also, the obtained results demonstrated that among the examined parameters, extraction pressure and nozzle diameter introduced the highest influence on the reduction of the cetirizine particle diameter. Furthermore, the SEM analysis revealed that the RESS process not only is able to reduce the particle size but also is able to modify the particle morphology from irregular shape to somehow spherical shape. Totally, based on the obtained results it can be concluded that RESS process is an applicable and feasible tool for producing the micron- and submicron-size particles of poorly soluble cetirizine particles.
NOTES

*Corresponding author.