A Comparison of Spinal Anesthesia with Levobupivacaine and Hyperbaric Bupivacaine for Cesarean Sections: A Randomized Trial ()
1. Introduction
Spinal anesthesia has a popular technique for caesarean delivery. Hyperbaric bupivacaine in 8% glucose is often used. Plain, or glucose-free, bupivacaine has been frequently referred to as “isobaric” in the literature, even after Blomqvist and Nilsson [1] demonstrated its hypobaricity. More recently, several studies have confirmed that plain bupivacaine is indeed hypobaric in comparison with human CSF [2-4]. Clinically, this manifests as an unpredictable median sensory block height with a large inter-individual spread and is occasionally associated with block failure when the spinal block has not spread high enough for surgery [5,6]. For this reason, hyperbaric bupivacaine is favored in obstetric anesthesia. Although hyperbaric local anesthetic solutions have a remarkable record of safety, their use is not totally without risk [7-9]. To prevent unilateral or saddle blocks, patients should move from the lateral or sitting position rapidly and after mobilization of the patients, extension or early return of the block may be seen. Hyperbaric solutions may couse sudden cardiac arrest after spinal anesthesia because of the extension of the sympathetic block [10,11]. The use of truly isobaric solutions may prove less sensitive to position issues. Hyperbaric solutions may cause hypotension or bradycardia after mobilization, isobaric solutions are favored with respect to their less sensitive to position issues properties [12].
Levobupivacaine is the pure S (-) enantiomer of racemic bupivacaine but is less toxic to the heart and CNS [13,14]. The plain levobupivacaine has been shown to be truly isobaric with respect to CSF of pregnant women [4, 15]. Its use in this setting may there offer special advantages because this property may translate to a more predictable spread.
In this randomized, double-blind study, we evaluated the influence of levobupivacaine on the quality of the block and the incidence of side effects, particularly hypotension and compared with clinic effect of hyperbaric bupivacaine in spinal anesthesia for cesarean sections.
2. Methods
After institutional ethical approval and informed consent were obtained, 60 women scheduled for elective Caesarean delivery, at more than 37 weeks’ gestation, ASA physical status class I or II, were enrolled into this prospective randomized, double-blind study.
Patients refusing regional anesthesia, having contraindications to spinal anesthesia, those with a body weight over 100 kg, shorter than 1.50 cm and taller than 1.75, those who received medications other than perinatal vitamin and iron preparations, having systemic diseases, expectant mothers with fetal anomaly, placenta previa, ablation placenta were excluded from the study.
Following application of routine monitors (noninvasive BP measurement, electrocardiography, and pulse oximetry) and insertion of a peripheral 20 G i.v cannula, a rapid infusion of lactated Ringer’s solution 10 ml/kg was administered. Baseline systolic BP and heard rate were calculated as the mean of the three recordings. Patients were placed in the sitting position. After disinfecting the skin and infiltrating with 2% lidocaine, lumbar puncture was performed at the L3-4 interspace using a 25-gauge Quincke point needle. Patients were randomly divided into two groups. For Group LF (n = 30); 10 mgr 0.5% (2 ml) levobupivacaine (chirocaine flacon 0.5% 10 ml injection solution, Abbott, USA) + 15 µcg (0.3 ml) fentanyl (Janssen-Cilag), for group BF (n = 30); 10 mgr 0.5% (2 ml) bupivacaine (marcaine spinal heavy 0.5% Abbott) + 15 µcg (0.3 ml) fentanyl, being a total of 2.3 cc, administered intrathecally within some 10 seconds. Subsequently, patients were turned to a 15˚ - 20˚ left lateral supine position. Oxygen 4 L/min was administered via a facial mask. The sensory level of spinal anesthesia was assessed bilaterally in the anterior axillary line by pinprick, using a short beveled 25 G needle, and was recorded at baseline prior to spinal injection, then every minute for the first 15 min after injection, and every five minutes for the next 30 min, and at 45 min. Blood pressure, heart rate, and the extent of motor block were recorded at the same measurement intervals. Permission to perform operation was given once a T4-T6 level had been achieved. Considering the time of intrathecal injection as time zero, the time to onset of sensory block, the time taken to reach maximum sensory block level, the time to regression of two dermatomes of the sensory block, the duration of the regression of the sensory block level to T12 from the maximum level were recorded. The level of motor block was assessed with modified Bromage scale (0 = no paralysis, able to flex hips/knees/ankles; 1 = able to move knees, unable to raise extended legs; 2 = able to flex ankles, unable to flex knees; 3 = unable to move any part of the lower limp). The time to onset of motor block, the time to reach Bromage 3 and the time of complete disappearance were recorded.
Bradycardia was defined as pulse rate < 50 bpm, and it was treated with 0.5 mg IV atropine.
IV boluses of 5 - 10 mg ephedrine and additional IV fluids were administered to treat hypotension, which was defined as systolic blood pressure below 100 mm Hg or a decrease systolic pressure of >25% from baseline value. The amount of ephedrine used for each patient was recorded. Whether there was a need for intraoperative analgesia and time to first analgesic requirement in the postoperative period were recorded and the planned treatment included incremental 25 µg boluses of IV fentanyl, or general anesthesia. Intraoperative and postoperative nausea and vomiting, and other side-effects were recorded.
The calculation of the required sample size was based on mean and standard deviation of complete regression of spinal block after anesthesia with bupivacaine and levobupivacaine reported in previous investigation (10, 11): 30 patients per group were required to detect a 20- min difference in time for complete regression of spinal anesthesia with an expected effect size to standard deviation ratio of 0.9 accepting a two-tailed a error of 5% and a b error of 20%. Statistical assessment of the data was carried out using the statistical software SPSS 15 for Windows l5. Shapiro-Wilks normality test was applied to see whether the data distribution was normal. For the variables that showed a normal distribution of inter group comparisons, independent two-sample t-test was used, for the variables, which did not show normal distribution, the Mann-Whitney U test was used. Within-group comparisons in repeated measurements were performed with the variance analysis. Comparisons between two qualitative variables were performed with Pearson’s chi-square test. p value < 0.05 was considered to be statistically significant.
3. Results
There has been no statistical difference between groups in terms of their demographic characteristics and the duration of the operation (Table 1). During the study period only in one case we experienced technical difficulty and could not perform spinal anesthesia. We gave general anesthesia to the patient and the case was excluded from the study. Both groups had achieved sufficient level of anesthesia and intraoperative analgesia and did not require additional analgesics.
The onset of sensory block and the time for the sensory block to reach T10 was similar in both groups (p > 0.05). The time taken for the sensory block to reach maximum level was shorter in Group LF and its maxi-
mum sensory block level was lower (p < 0.05).
The time to regression by two dermatomes for the sensory block and its regression time to T12 were longer in Group BF (p < 0.05) (Table 2).
The time to onset of motor block in Group BF was shorter than Group LF (p < 0.05). Complete motor block was obtained within 20 minutes in every patient in both groups (Bromage 3). Motor block developed faster and lasted longer with the hyperbaric bupivacaine (p < 0.05) (Table 3).
Hypotension and bradycardia were more common in the BF group. In addition, nausea was noticed more frequently in the BF group (p < 0.05) (Table 4).
Other side effects such as headache, backache, itching and vomiting in the groups were similar.
It was observed that the requirement of intraoperative ephedrine was higher in Group BF and the time to first analgesic requirement was longer in Group BF (p > 0.05) (Table 5).
4. Discussion
In our study, sensory block levels required for cesarean section were achieved in both groups, and it was observed that the hemodynamic stability with levobupivacaine was better maintained.
In most of the studies where the same doses of levobupivacaine and bupivacaine were investigated, sensory and motor block characteristics were found to be similar. Glaser et al. compared 3.5 ml [16] and Fattorini et al.

Table 2. Characteristics of sensory blocks.

Table 3. Characteristics of motor blocks.

Table 4. Side effects observed in the groups.

Table 5. Amounts of ephedrine administered and time to first analgesic requirement in the groups.
compared 3 ml [17] 0.5% isobaric bupivacaine with levobupivacaine, and both reported that there was no significant difference in terms of maximum distribution, and durations of sensory and motor block. In a study on urological surgery, it has been reported that 2.5 ml 0.5% isobaric levobupivacaine and 2.5 ml 0.5% hyperbaric bupivacaine had equal effects in spinal anesthesia and that the time to onset of sensory block and duration of sensory block were similar [18]. In a dose-effect study comparing racemic bupivacaine and levobupivacaine in patients undergoing urological surgery, Lee et al. [19] reported that 2.6 ml 0.5% racemic bupivacaine and levobupivacaine have a nearly equivalent clinic profile and hemodynamic effects. In another study conducted in volunteers, spinal anesthesia was administered in doses of 4, 8, 12 mg by using hyperbaric spinal levobupivacaine and racemic bupivacaine, sensory and motor block characteristics in different doses were compared. It has been reported that in the same doses hyperbaric levobupivacaine and racemic bupivacaine had the same effects [20].
We observed in our study that maximum sensory block level in bupivacaine group was higher and development of motor block was faster and lasted longer. The results of our study are contradictory to those from the studies mentioned above. However, similar results have been also reported by Gautier et al. [21] during spinal anesthesia for caesarean delivery. They compared the same doses of levobupivacaine and bupivacaine, and reported that while adequate anesthesia was maintained in the 97% of the patients in the bupivacaine group, this rate was 80% in the levobupivacaine group, and duration of motor block and analgesia was shorter in the levobupivacaine. In our study also, sensory and motor block durations were found to be shorter in the levobupivacaine group. The effects of baricite on the block characteristisc have been contradictory in literature: while some studies that report the difference in baricite does not affect block charecteristics [22] on the one hand, there are also studies reporting that motor block develops and disappears faster when hyperbaric solutions are used [23] on the other hand. Therefore we cannot ascribe the difference of sensory and motor block between the two groups in our study to the difference of baricite only.
Fentanyl is widely used to increase the duration of analgesia without increasing the duration of motor block, and to reduce required local anesthetic dosage [24]. Choi et al. [25] reported that the combination of 8 mg bupivacaine and 10 μg fentanyl is as efficient as 12 mg of hyperbaric bupivacaine. The number of studies on the effects of the combination of intrathecal levobupivacainefentanyl [26] is limited, and the data on appropriate dosages for caesarean sections are inadequate. Prior to our research, we undertook a pilot study using the different dosages given in the literature, to determine the dosages to be used in our study.
Hypotension is the most common complication in the spinal anesthesia [27]. It is known that besides its effects on the mother, it causes acidosis by altering uteroplacental perfusion. Administering hydration using crystalloid or colloid before the spinal anesthesia has proved insufficient [28]. Titti et al. [29] reported that the rate of occurrence of hypotension was 62% in elective cesarean operations in which they administrated spinal anesthesia with 2.5 ml 0.5% bupivacaine. In our study, the incidence of hypotension with bupivacaine was found to be 36.6%. We believe that this difference in our results might be related to the fact that we had decreased the dose of local anesthetic and added fentanyl. The incidence of hypotension was significantly reduced to 16.6% in the doses we used in the levobupivacaine group. Fattorini et al. [17] reported that although they did not observe a significant difference in the sensory and motor block characteristics of levobupivacaine and bupivacaine among 60 patients who undergo major orthopedic surgery, they did not find severe hypotension and better cardiovascular stability was provided in the levobupivacaine group, Parpaglioni et al. [30] investigated minimum local anesthetic dose in caesarean sections, and they reported that in the levobupivacaine group, in which they administered similar doses with our study, the incidence of hypotension decreased significantly. Gunusen et al. [31] have compaired different doses of levobupivacaine-fentanyl combination in cesarean section and reported that 10 mg levobupivacaine with 10 µg fentanyl combination provides 100% effective anesthesia but the incidance of hypotension was high. The higher hypotension rates reported by Gunusen et al. may be related to the difference in the definition of hypotension between the studies. While they considered 20% decline of systolic blood pressure from baseline values as hypotension, we accepted the 25% decline as hypotension.
That the rate given as 38.5% in levobupivacaine group seems far higher than our results might have stemmed from the fact that while they regard a 20% decrease in blood pressure from the baseline value as hypotension, we consider a 25% decrease as hypotension.
Glasser et al. [11] in line with our study, reported that levobupivacaine, compared with bupivacaine, causes less bradycardia, and that reduces arterial pressure less.
In regional anesthesia for caesarean sections, nausea and vomiting can occur due to a few factors. The most important reason is that cerebral blood flow decreases in consequence of hypotension. Other reasons are related to the level where block reaches. It may as well occur because of an increase in the block level, or because of the fact that structures related to peritonea stretch during the operation due to an inadequate block level. We can explain the reduced incidence of nausea occurred in the levobupivacaine group with the fact that the doses we administered developed adequate blocks, and caused less hypotension.
5. Conclusion
We conclude that single-shot spinal anesthesia performed with both local anesthetic drugs provides fast and effective induction of surgical anesthesia for elective cesarean section. Since motor block time is shorter, and side effects like hypotension, bradycardia and nausea are less, the combination of levobupivacaine + fentanyl can be a good alternative in cesarean sections.