Article citationsMore>>
Dames, P., Gleich, B., Flemmer, A., Hajek, K., Seidl, N., Wiekhorst, F., Eberbeck, D., Bittmann, I., Bergemann, C., Weyh, T., Trahms, L., Rosenecker, J. and Rudolph, C. (2007) Targeted Delivery of Magnetic Aerosol Droplets to the Lung. Nature Nanotechnology, 2, 495-499.
http://dx.doi.org/10.1038/nnano.2007.217
has been cited by the following article:
-
TITLE:
Application of Magnetic Particle Imaging to Pulmonary Imaging Using Nebulized Magnetic Nanoparticles
AUTHORS:
Kohei Nishimoto, Atsushi Mimura, Marina Aoki, Natsuo Banura, Kenya Murase
KEYWORDS:
Magnetic Particle Imaging, Pulmonary Imaging, Nebulized Magnetic Nanoparticles, Animal Experiments
JOURNAL NAME:
Open Journal of Medical Imaging,
Vol.5 No.2,
May
25,
2015
ABSTRACT: Purpose: To investigate the feasibility of applying magnetic particle imaging (MPI) to pulmonary imaging using nebulized magnetic nanoparticles (MNPs) and to quantify the mucociliary clearance in the lung, using small animal experiments. Materials and Methods: Intrapulmonary administration of MNPs was performed in seven-week-old male ICR (Institute of Cancer Research) mice (n = 8) using a nebulized microsprayer connected to a high-pressure syringe containing 50 μL of MNPs (500 mM Resovist®). We imaged the lungs using our MPI scanner 2.5 hours, 1 day, 3 days, and 7 days after the intrapulmonary administration of MNPs. The average MPI value was calculated by drawing a region of interest (ROI) on the lungs by taking the threshold value for extracting the contour as 20% of the maximum MPI value within the ROI. The MPI value was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. Mice were sacrificed immediately after the last MPI and X-ray CT studies on day 7, and 5 lobes of the lung in each mouse were extracted to confirm the accumulation of iron using Berlin blue staining. Results: We could visualize the distribution of MNPs in the lungs as positive contrast using MPI with use of nebulized MNPs. The presence of iron in the lung was confirmed by Berlin blue staining. The average MPI value decreased with time and tended to saturate. The clearance rate was calculated to be 0.505 day−1 from the time course of the average MPI value in the lungs. Conclusion: Our preliminary results suggest that MPI can be applied to pulmonary imaging by nebulizing MNPs and can be useful for quantifying the mucociliary clearance in the lung.
Related Articles:
-
Affi Jeanne Bongoua-Devisme, Wondouet Hippolyte Kpan, Pla Kouassi Adou, Franck Michaël Lemonou Bahan, Konan-Kan Hippolith Kouadio, Anselme Kan Louis Koko
-
Brou Julien Kouakou, Koffi Christophe Kobenan, Kouadio Emmanuel N’Goran, Malanno Kouakou, Nogbou Ferdinand Amangoua, Diane Ester Gnapi
-
Joachim Sonntag
-
Ramy Shaheen, Ziad Kanaya, Samar Jakhlab
-
Qing-Lai Dang, Junlin Li, Rongzhou Man