TITLE:
Stability Indicating RP-HPLC Method for Quantification of Impurities in Valsartan and Hydrochlorothiazide FDC Tablet Dosage Form
AUTHORS:
Hari Kishan Reddy Ganthi, Raveendra Reddy P, Young Jun Park, So Jin Park, Woo Hyong Cho
KEYWORDS:
Valsartan, Hydrochlorothiazide, RP-HPLC, Impurities, Method Validation
JOURNAL NAME:
American Journal of Analytical Chemistry,
Vol.7 No.11,
November
30,
2016
ABSTRACT: A stability-indicating RP-HPLC method has been developed and validated for simultaneous determination of Valsartan & Hydrochlorothiazide and their impurities in FDC (Fixed Dose Combination) tablet dosage form. The method was developed using L1 column (250 × 4.6 mm; 5 μm) with gradient elution using the mobile phase consisting of solvent-A (0.1% Ortho phosphoric acid) and solvent-B (100% Acetonitrile); the gradient program (Tmin/%B) was set as 0/10, 5/10, 20/60, 40/60, 41/10 and 50/10. The eluted compounds were monitored at 265 nm. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantitation, accuracy, precision and robustness. The influence of Acid, Alkaline, Oxidative, Photolytic, Thermal and Humidity stress conditions, on drug product was studied. The limit of quantification results of Valsartan, Hydrochlorothiazide and their impurities are, VAL: 0.303 μg/mL, HCTZ: 0.019 μg/mL, VAL RC-B: 0.085 μg/mL, VAL RC-C: 0.327 μg/mL, HCT RC-A: 0.017 μg/mL, CTZ: 0.080 μg/mL and 5-Chloro HCT: 0.047 μg/mL. The proposed method is suitable for the estimation of Valsartan & Hydrochlorothiazide impurities in tablets dosage form.