Bradycardia Secondary to Negative Suction Pressure Applied to Chest Drain

HTML  XML Download Download as PDF (Size: 538KB)  PP. 216-221  
DOI: 10.4236/crcm.2019.88026    546 Downloads   1,815 Views  

ABSTRACT

Positive pressure generated in peritoneal cavity by gas insufflation during laparoscopic procedures can cause hemodynamic instability. There are a few case reports suggesting similar occurrences during thoracoscopic procedures as well. The mechanism behind the conditions above is explained to be due to stretch force applied to peritoneum and pleura which causes vagal stimulation. We wish to present a case where a high negative pressure applied to pleural cavity lead to treatment-resistant bradycardia. The possible mechanism behind this occurrence was traction pressure on pleura which triggered vagal activity. The bradycardia subsided on reducing or discontinuing negative suction pressure. To best of our knowledge this the first case report on bradycardia associated with high negative suction pressure applied to inter costal drain.

Share and Cite:

Arya, S. , Belwal, S. , Saxena, S. and Uniyal, B. (2019) Bradycardia Secondary to Negative Suction Pressure Applied to Chest Drain. Case Reports in Clinical Medicine, 8, 216-221. doi: 10.4236/crcm.2019.88026.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License