<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article  PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "http://dtd.nlm.nih.gov/publishing/3.0/journalpublishing3.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="3.0" xml:lang="en" article-type="research article"><front><journal-meta><journal-id journal-id-type="publisher-id">SS</journal-id><journal-title-group><journal-title>Surgical Science</journal-title></journal-title-group><issn pub-type="epub">2157-9407</issn><publisher><publisher-name>Scientific Research Publishing</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.4236/ss.2015.68052</article-id><article-id pub-id-type="publisher-id">SS-58475</article-id><article-categories><subj-group subj-group-type="heading"><subject>Articles</subject></subj-group><subj-group subj-group-type="Discipline-v2"><subject>Medicine&amp;Healthcare</subject></subj-group></article-categories><title-group><article-title>
 
 
  The Role of Ultrasound and Air Leak Measurement in Assessing Lung Expansion after Thoracic Surgery
 
</article-title></title-group><contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>braham</surname><given-names>Chavarín</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Laureano</surname><given-names>Molins</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1"><sup>*</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jose</surname><given-names>M. Mier</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Juan</surname><given-names>J. Fibla</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Cristina</surname><given-names>Izquierdo-Vidal</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Cristina</surname><given-names>Simon</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Angela</surname><given-names>Guirao</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Jorge</surname><given-names>Hernandez</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib></contrib-group><aff id="aff2"><addr-line>Department of Thoracic Surgery, Instituto Nacional de Enfermedades Respiratorias, México D.F., México</addr-line></aff><aff id="aff4"><addr-line>Department of Radiology, Hospital Universitari Sagrat Cor, Barcelona, Spain</addr-line></aff><aff id="aff3"><addr-line>Department of Thoracic Surgery, Hospital Clinic, Barcelona, Spain</addr-line></aff><aff id="aff1"><addr-line>Department of Thoracic Surgery, Hospital Universitari Sagrat Cor, Barcelona, Spain</addr-line></aff><author-notes><corresp id="cor1">* E-mail:<email>lmolins@clinic.ub.es(LM)</email>;</corresp></author-notes><pub-date pub-type="epub"><day>24</day><month>07</month><year>2015</year></pub-date><volume>06</volume><issue>08</issue><fpage>352</fpage><lpage>357</lpage><history><date date-type="received"><day>18</day>	<month>June</month>	<year>2015</year></date><date date-type="rev-recd"><day>accepted</day>	<month>27</month>	<year>July</year>	</date><date date-type="accepted"><day>30</day>	<month>July</month>	<year>2015</year></date></history><permissions><copyright-statement>&#169; Copyright  2014 by authors and Scientific Research Publishing Inc. </copyright-statement><copyright-year>2014</copyright-year><license><license-p>This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/4.0/</license-p></license></permissions><abstract><p>
 
 
  Objective: To determine if lung ultrasound semiology is applicable to the post-surgical hemithorax, and its value in the evaluation of lung expansion in the postoperative period when paired with the use of digital chest drain systems. Methods: Prospective observational study including all patients undergoing thoracic surgery from June 2012 to March 2013. Patients undergoing pleurodesis or hemodynamically unstable were not considered candidates. Final inclusion in the study was based on the availability of digital chest drain system. A transthoracic lung ultrasound evaluation of the anterior and anterolateral windows was performed 20 minutes after chest drain placement. Presence or not of lung sliding and air leak values taken from the digital chest drain system were recorded. Data were submitted to a binomial classification test for analysis. Results: Forty-nine patients were included, yielding a total of 64 hemithoraces. Lung sliding was seen in 53 cases (82.8%), and an air leak value of 20 ml/min or less in 56 cases (87.5%). Sensitivity was 92.8% (95% CI: 82.6% to 97.9%) and specificity 87.5% (95% CI: 47.3% to 97.9%). Positive predictive value was 98.1%, and negative predictive value was 63.6%. Conclusions: Transthoracic lung ultrasound is a useful technique that can complement the use of digital chest drain systems in the evaluation of post-surgical lung expansion. The incorporation of lung ultrasound can greatly reduce the need for chest radiographs in thoracic surgery departments.
 
</p></abstract><kwd-group><kwd>Thoracic Surgery</kwd><kwd> Pneumothorax</kwd><kwd> Ultrasonography</kwd><kwd> Lung Expansion</kwd><kwd> Chest Radiograph</kwd></kwd-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>With the publication of the BLUE protocol [<xref ref-type="bibr" rid="scirp.58475-ref1">1</xref>] ―Bedside Lung Ultrasound Evaluation―a lung ultrasound semiology has been consolidated. Concepts like the “seashore sign” (lung sliding) shown in <xref ref-type="fig" rid="fig1">Figure 1</xref>, or the “stratosphere sign” shown in <xref ref-type="fig" rid="fig2">Figure 2</xref> (pneumothorax) are becoming mainstream in many emergency medicine and intensive care units that use lung ultrasound in patient evaluation. The visualization of lung sliding is the basic principle in lung ultrasound. The pleural line is the image formed by the two pleurae in contact with each other. Lung sliding is the sparkling movement of the pleural line with ventilatory movements. In 1995, Lichtenstein et al. [<xref ref-type="bibr" rid="scirp.58475-ref2">2</xref>] , demonstrated that lung sliding was absent in 100% of pneumothoraces. Galbois et al. [<xref ref-type="bibr" rid="scirp.58475-ref3">3</xref>] proved in their series that lung ultrasound was more effective than conventional chest X-rays in the diagnosis of residual pneumothorax. When compared with a computer aided tomography scan, lung ultrasound identified 100% of residual pneumothorax while chest X-ray only detected 61%. Our aim is to determine if lung ultrasound is applicable in post-surgical thorax and its value in the evaluation of lung expansion in a post-operative care setting.</p></sec><sec id="s2"><title>2. Patients and Methods</title><p>This is a prospective observational study including patients undergoing thoracic surgery in the period from June 2012 to March 2013. In all the patients a digital chest drain system was employed. The work was conducted in compliance with our Institutional Review Board and Human Subjects Research Committee requirements. Informed written consent was obtained in pre-surgical evaluation in all cases that were considered to meet inclusion criteria. In order to obtain 95% confidence intervals with a range of &#177;3, and 80% power calculations a minimum sample size of 60 hemithoraces was required.</p><p>Patients with hemodynamic instability were excluded as well as patients that underwent pleurodesis. A transthoracic lung ultrasound evaluation of the anterior (second intercostal space at the midclavicular line) and the anterolateral (fourth or fifth intercostal space at the anterior axillary line) wall was performed 20 minutes after chest drain placement. These particular windows were preferred due to the presence of surgical wound dressings in most cases. The presence (“seashore sign” <xref ref-type="fig" rid="fig1">Figure 1</xref>) or absence (“stratosphere sign” <xref ref-type="fig" rid="fig2">Figure 2</xref>) of</p><fig id="fig1"  position="float"><label><xref ref-type="fig" rid="fig1">Figure 1</xref></label><caption><title> Seashore sign. The pleural line is the image formed by the two pleurae in contact with each other. This sign is a normal finding of lung sliding. In absence of a seashore sign or presence of a stratosphere sign, pneumothorax is likely</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-2300902x6.png"/></fig><fig id="fig2"  position="float"><label><xref ref-type="fig" rid="fig2">Figure 2</xref></label><caption><title> Stratosphere sign. Pleura and lung are indistinguishable as linear hyperechogenic lines. This sign is fairly reliable for diagnosis of a pneumothorax (absence of lung expansion)</title></caption><graphic mimetype="image"   position="float"  xlink:type="simple"  xlink:href="http://html.scirp.org/file/3-2300902x7.png"/></fig><p>lung sliding was recorded. The absence of lung sliding in either window was considered a pneumothorax. A digital chest drain system measurement was registered at the time of the evaluation. Digital air leak measurements of 20 ml/min or less were considered as fully expanded and deemed for chest drain removal if no other indication for a chest drain was present (i.e. effusion, discharge, promptness). In all cases, a digital chest X-ray was obtained at a later time, and standard chest drainage management procedure was followed. Data were analyzed as a single group and then divided into two sub-groups based on the type of procedure performed: mainly pulmonary surgery and non-pulmonary surgery. All data collected were submitted to a binomial classification test for analysis. Continuous quantitative values were expressed as means. Sensitivity and specificity were calculated as appropriate and 95% confidence interval (CI) was included for statistical comparison.</p></sec><sec id="s3"><title>3. Results</title><p>A sample of 50 patients was obtained. One case had to be excluded due to digital chest drain malfunction. The remaining sample consisted of 49 patients (37 male/12 female), with a mean age of 45.75 years. It yielded a total of 64 hemithoraces for study as bilateral procedures were counted as independent procedures (<xref ref-type="table" rid="table1">Table 1</xref>).</p><p>In the evaluation of the full sample (n = 64), lung sliding was found in 53 cases (82.8%), and an air leak value of 20 ml/min or less was seen in 56 cases (87.5%). Sensitivity was 92.8% (95% CI: 82.6% to 97.9%) and specificity 87.5% (95% CI: 47.3% to 97.9%). Positive predictive value was 98.1% and Negative predictive value 63.6% (<xref ref-type="table" rid="table2">Table 2</xref>, and <xref ref-type="table" rid="table3">Table 3</xref>).</p><sec id="s3_1"><title>3.1. Non-Pulmonary Surgery</title><p>This group included 35 hemithoraces, procedures included are listed in <xref ref-type="table" rid="table1">Table 1</xref>. Lung sliding was found in 35/35 (100%). Digital air leak of 20 ml/min or less was present in 100% of cases (35/35). Sympathectomy and sympathectomy reversal patients were also analyzed as a separate subgroup (n = 29) as these cases were part of our out-patient surgical unit and chest X-ray was available within 25 minutes after digital chest drain placement. Full lung expansion was found in 29/29 (100%) of the X-rays, lung sliding was present in 29/29 cases (100%) and a digital air leak measurement of 20ml/min or less was found in 29/29 hemithoraces (100%).</p><table-wrap id="table1" ><label><xref ref-type="table" rid="table1">Table 1</xref></label><caption><title> Demographics and patients</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Characteristic</th><th align="center" valign="middle" >Value</th></tr></thead><tr><td align="center" valign="middle" >Number of patients</td><td align="center" valign="middle" >49</td></tr><tr><td align="center" valign="middle" >Number of hemithoraces</td><td align="center" valign="middle" >64</td></tr><tr><td align="center" valign="middle" >Gender, n (%) Male Female</td><td align="center" valign="middle" >37 (75.5%) 12 (24.5%)</td></tr><tr><td align="center" valign="middle" >Age, mean (SD)</td><td align="center" valign="middle" >45.7 (12)</td></tr><tr><td align="center" valign="middle" >Non-pulmonary procedures by type, n Sympathectomy Thymomas Mediastinal tumors Sympathectomy reversal Pleural nodule</td><td align="center" valign="middle" >35 27 3 2 2 1</td></tr><tr><td align="center" valign="middle" >Pulmonary procedures by type, n VATS, left wedge resection VATS, right wedge resection Lobectomy, left Lobectomy, right Mid sternotomy, right nodule Pneumothorax</td><td align="center" valign="middle" >29 11 9 3 3 1 2</td></tr></tbody></table></table-wrap><table-wrap id="table2" ><label><xref ref-type="table" rid="table2">Table 2</xref></label><caption><title> Total number of diagnostic examinations</title></caption><table><tbody><thead><tr><th align="center" valign="middle" ></th><th align="center" valign="middle" >True positive</th><th align="center" valign="middle" >True negative</th><th align="center" valign="middle" >False positive</th><th align="center" valign="middle" >False negative</th></tr></thead><tr><td align="center" valign="middle" >Total sample</td><td align="center" valign="middle" >52</td><td align="center" valign="middle" >7</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >4</td></tr><tr><td align="center" valign="middle" >Pulmonary procedures</td><td align="center" valign="middle" >17</td><td align="center" valign="middle" >7</td><td align="center" valign="middle" >1</td><td align="center" valign="middle" >4</td></tr></tbody></table></table-wrap><table-wrap id="table3" ><label><xref ref-type="table" rid="table3">Table 3</xref></label><caption><title> Evaluation of lung sliding</title></caption><table><tbody><thead><tr><th align="center" valign="middle" >Variables</th><th align="center" valign="middle" >Total sample</th><th align="center" valign="middle" >Pulmonary procedures</th></tr></thead><tr><td align="center" valign="middle" >Sensitivity % (95% CI)</td><td align="center" valign="middle" >92.8% (82.9, 97.8)</td><td align="center" valign="middle" >80.5% (58.8, 94.4)</td></tr><tr><td align="center" valign="middle" >Specificity % (95% CI)</td><td align="center" valign="middle" >87.5% (47.3, 97.9)</td><td align="center" valign="middle" >87.5% (47.3, 97.9)</td></tr><tr><td align="center" valign="middle" >Disease prevalence % (95% CI)</td><td align="center" valign="middle" >87.5% (76.8, 94.4)</td><td align="center" valign="middle" >72.4% (52.7, 87.2)</td></tr><tr><td align="center" valign="middle" >PPV % (95% CI)</td><td align="center" valign="middle" >98.1% (89.9, 99.6)</td><td align="center" valign="middle" >94.4% (72.6, 99.0)</td></tr><tr><td align="center" valign="middle" >NPV % (95% CI)</td><td align="center" valign="middle" >63.6% (30.8, 88.8)</td><td align="center" valign="middle" >63.6% (30.8, 88.8)</td></tr></tbody></table></table-wrap><p>PPV = Predictive Positive Value; NPV = Negative Predictive Value.</p></sec><sec id="s3_2"><title>3.2. Pulmonary Surgery</title><p>Twenty-nine hemithoraces were evaluated. Lung sliding was present in 18 cases (62%). Digital air leak value of 20 ml/min or less was found in 21 cases (72%). Inter-rate agreement (Weighted Kappa) was 0.61. Sensitivity was 80.9% (95% CI: 58.0% to 94.4%), and specificity 87.5% (95% CI: 47.3% to 97.9%). Positive and negative predictive values were 94.4% (95% CI: 72.6% to 99.0%) and 63.6% (95% CI: 30.8% to 88.8%) respectively (<xref ref-type="table" rid="table3">Table 3</xref>).</p></sec></sec><sec id="s4"><title>4. Discussion</title><p>Lung ultrasound has been proven to be almost as accurate as CT scanning in detecting the presence of pneumothorax [<xref ref-type="bibr" rid="scirp.58475-ref4">4</xref>] occult pneumothorax and its extension [<xref ref-type="bibr" rid="scirp.58475-ref5">5</xref>] . In the present study and after analyzing 49 patients (64 hemothoraces) we found that ultrasound had a sensitivity of 92.8%, a specificity of 87.5%, a positive predictive value of 98.1%, and a negative predictive value of 63.6%. Our results showed that lung sliding is a good indicator of lung expansion, especially when paired with digital air leak measurements. After analyzing our results we found out that the addition of lung ultrasound evaluation showing lung sliding sign and a digital air leak value of 20 ml/min or less in non-pulmonary surgery patients allows a safe exclusion of pneumothorax.</p><p>The results found in our sympathectomy sub-group were identical to those published by Saucier et al. [<xref ref-type="bibr" rid="scirp.58475-ref6">6</xref>] , who reported a perfect agreement between lung ultrasound and chest radiography to detect pneumothorax in a series of 50 cardiothoracic surgery patients.</p><p>Our results were also comparable to those found by Shostak E. et al. [<xref ref-type="bibr" rid="scirp.58475-ref7">7</xref>] in a similar study but with minor procedures. They performed transthoracic ultrasound in a series of 185 patients submitted to thoracentesis, transbronchial biopsy and computed tomography-guided needle lung biopsy. The sensitivity and specificity were 88% and 97% respectively.</p><p>However, not all the studies have found an optimal accuracy of ultrasound evaluation in the detection of lung expansion. Goudie et al. [<xref ref-type="bibr" rid="scirp.58475-ref8">8</xref>] in a prospective cohort trial of 120 patients submitted to thoracic surgery and bedside postoperative ultrasound evaluation, found a sensitivity and specificity in the detection of postoperative pneumothorax of 21.2% and 94.7%. They justified the low sensitivity arguing that postoperative inflammation within the pleural cavity could affect the interpretations of ultrasonographic findings indicative of a pneumothorax. It is accepted that postoperative pleural inflammation makes more difficult to detect pneumothorax, however we believe that with an adequate training this should not become a problem. Surgeons performing echography in Goudi et al. al study did not have a large experience in echography, indeed they had an intensive 2- week training period focused on basic chest ultrasound. We believe this is enough training to detect pleural effusions but not sufficient for a high accuracy in detecting lung expansion following thoracic surgery. A longer training is adviced for this purpose―of 1 month at least.</p><p>Digital chest drain systems are considered superior to traditional water seal devices and its use is extending [<xref ref-type="bibr" rid="scirp.58475-ref9">9</xref>] . However there is not such a consensus regarding ultrasound benefits in thoracic surgery patients. Different studies have been published proving bedside ultrasound is a valuable tool in the management of these patients [<xref ref-type="bibr" rid="scirp.58475-ref7">7</xref>] [<xref ref-type="bibr" rid="scirp.58475-ref10">10</xref>] - [<xref ref-type="bibr" rid="scirp.58475-ref16">16</xref>] , meanwhile other authors have warned about the limitations of the technique [<xref ref-type="bibr" rid="scirp.58475-ref8">8</xref>] [<xref ref-type="bibr" rid="scirp.58475-ref17">17</xref>] -[<xref ref-type="bibr" rid="scirp.58475-ref20">20</xref>] .</p><p>To our knowledge the present study is the first one demonstrating a high accuracy of bedside ultrasound evaluation combined with digital chest drain systems in the detection of postoperative lung expansion.</p><p>Our study has limitations. It is a prospective cohort with a limited number of patients. In the Pulmonary surgery group, we found that the absence of lung sliding can coexist with digital air leak values of 20 ml/min or less. This anomalous situation can be explained by the following: a. Resection volume and site, and b. irregular compensatory lung expansion. Video Assisted Thoracoscopic (VAT) wedge resections do not follow a strict anatomic pattern making compensatory lung expansion less predictable. Larger resections have increased the probability of the probe being placed directly over the resected area thus leading to a false image of pneumothorax. The presence of an air leak value of 20 ml/min or less in these cases supports the fact that it is an anatomical defect of the lung rather than a pneumothorax that yields the false negative result in the ultrasound evaluation.</p></sec><sec id="s5"><title>5. Conclusion</title><p>Bedside trans-thoracic ultrasound evaluation combined with a digital chest drain system has the potential to be effective and convenient in the detection of lung expansion after thoracic surgery. Future prospective randomized studies are warranted to confirm these findings and determine whether this postoperative management policy is able to minimize the use of postoperative chest X-rays.</p></sec><sec id="s6"><title>Cite this paper</title><p>AbrahamChavar&#237;n,LaureanoMolins,Jose M.Mier,Juan J.Fibla,CristinaIzquierdo-Vidal,CristinaSimon,AngelaGuirao,JorgeHernandez, (2015) The Role of Ultrasound and Air Leak Measurement in Assessing Lung Expansion after Thoracic Surgery. Surgical Science,06,352-357. doi: 10.4236/ss.2015.68052</p></sec><sec id="s7"><title>NOTES</title></sec></body><back><ref-list><title>References</title><ref id="scirp.58475-ref1"><label>1</label><mixed-citation publication-type="other" xlink:type="simple">Lichtenstein, D.A. and Meziere, G.A. (2008) Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure: The BLUE Protocol. Chest, 134, 117-125. http://dx.doi.org/10.1378/chest.07-2800</mixed-citation></ref><ref id="scirp.58475-ref2"><label>2</label><mixed-citation publication-type="other" xlink:type="simple">Lichtenstein, D.A. and Menu, Y. (1995) A Bedside Ultrasound Sign Ruling out Pneumothorax in the Critically Ill. Lung Sliding. Chest, 105, 1345-1348. http://dx.doi.org/10.1378/chest.108.5.1345</mixed-citation></ref><ref id="scirp.58475-ref3"><label>3</label><mixed-citation publication-type="other" xlink:type="simple">Galbois, A., Ait-Oufella, H., Baudel, J.L., Kofman, T., Bottero, J., Viennot, S., et al. (2010) Pleural Ultrasound Compared with Chest Radiographic Detection of Pneumothorax Resolution after Drainage. Chest, 128, 648-655. http://dx.doi.org/10.1378/chest.09-2224</mixed-citation></ref><ref id="scirp.58475-ref4"><label>4</label><mixed-citation publication-type="other" xlink:type="simple">Saucier, S., Motyka, C. and Killu, K. (2010) Ultrasonography versus Chest Radiography after Chest Tube Removal for the Detection of Pneumothorax. AACN Advanced Critical Care, 21, 34-38. http://dx.doi.org/10.1097/NCI.0b013e3181c8013a</mixed-citation></ref><ref id="scirp.58475-ref5"><label>5</label><mixed-citation publication-type="other" xlink:type="simple">Ahston-Cleary, D.T. (2013) Is Thoracic Ultrasound a Viable Alternative to Conventional Imaging in the Critical Care Setting? British Journal of Anaesthesia, 111, 152-160. http://dx.doi.org/10.1093/bja/aet076</mixed-citation></ref><ref id="scirp.58475-ref6"><label>6</label><mixed-citation publication-type="other" xlink:type="simple">Soldati, G., Testa, A., Sher, S., Pignataro, G., La Sala, M. and Silveri, N.G. (2008) Occult Traumatic Pneumothorax: Diagnostic Accuracy of Lung Ultrasonography in the Emergency Department. Chest, 133, 204-211. http://dx.doi.org/10.1378/chest.07-1595</mixed-citation></ref><ref id="scirp.58475-ref7"><label>7</label><mixed-citation publication-type="other" xlink:type="simple">Shostak, E., Brylka, D., Krepp, J., Pua, B. and Sanders, A. (2013) Bedside Sonography for Detection of Postprocedure Pneumothorax. Journal of Ultrasound in Medicine, 32, 1003-1009. http://dx.doi.org/10.7863/ultra.32.6.1003</mixed-citation></ref><ref id="scirp.58475-ref8"><label>8</label><mixed-citation publication-type="other" xlink:type="simple">Goudie, E., Bah, I., Khereba, M., Ferraro, P., Duranceau, A., Martin, J., Thiffault, V. and Liberman, M. (2012) Prospective Trial Evaluating Sonography after Thoracic Surgery in Postoperative Care and Decision Making. European Journal of Cardio-Thoracic Surgery, 41, 1025-1030. http://dx.doi.org/10.1093/ejcts/ezr183</mixed-citation></ref><ref id="scirp.58475-ref9"><label>9</label><mixed-citation publication-type="other" xlink:type="simple">Pompili, C., Detterbeck, F., Papagiannopoulos, K., Sihoe, A., Vachlas, K., Maxfield, M.W., Lim, H.C. and Brunelli, A. (2014) Multicenter International Randomized Comparison of Objective and Subjective Outcomes between Electronic and Traditional Chest Drainage Systems. Annals of Thoracic Surgery, 98, 490-496.http://dx.doi.org/10.1016/j.athoracsur.2014.03.043</mixed-citation></ref><ref id="scirp.58475-ref10"><label>10</label><mixed-citation publication-type="other" xlink:type="simple">Lisi, M., Cameli, M., Mondillo, S., Luzzi, L., Zaca, V., Cameli, P., et al. (2012) Incremental Value of Pocket-Sized Imaging Device for Bedside Diagnosis of Unilateral Pleural Effusions and Ultrasound-Guided Thoracentesis. Interactive Cardiovascular and Thoracic Surgery, 15, 596-601. http://dx.doi.org/10.1093/icvts/ivs223</mixed-citation></ref><ref id="scirp.58475-ref11"><label>11</label><mixed-citation publication-type="other" xlink:type="simple">Peris, A., Tutino, L., Zagli, G., Batacchi, S., Cianchi, G., Spina, R., et al. (2010) The Use of Point-of-Care Bedside Lung Ultrasound Significantly Reduces the Number of Radiographs and Computed Tomography Scans in Critically Ill Patients. Anesthesia &amp; Analgesia, 111, 687-692. http://dx.doi.org/10.1213/ANE.0b013e3181e7cc42</mixed-citation></ref><ref id="scirp.58475-ref12"><label>12</label><mixed-citation publication-type="other" xlink:type="simple">Lavingia, K.S., Soult, M.C., Collins, J.N., Novosel, T.J., Weireter, L.J. and Britt, L.D. (2014) Basic Ultrasound Training Can Replace Chest Radiography for Safe Tube Thoracostomy Removal. The American Surgeon, 80, 783-786.</mixed-citation></ref><ref id="scirp.58475-ref13"><label>13</label><mixed-citation publication-type="other" xlink:type="simple">Soult, M.C., Collins, J.N., Novosel, T.J., Weireter, L.J. and Britt, L.D. (2014) Thoracic Ultrasound Can Predict Safe Removal of Thoracostomy Tubes. Journal of Trauma and Acute Care Surgery, 77, 256-261.http://dx.doi.org/10.1097/TA.0000000000000315</mixed-citation></ref><ref id="scirp.58475-ref14"><label>14</label><mixed-citation publication-type="other" xlink:type="simple">Andruszkiewicz, P. and Sobczyk, D. (2013) Ultrasound in Critical Care. Anestezjologia Intensywna Terapia, 45, 177-181. http://dx.doi.org/10.5603/AIT.2013.0036</mixed-citation></ref><ref id="scirp.58475-ref15"><label>15</label><mixed-citation publication-type="other" xlink:type="simple">Kwan, R.O., Miraflor, E., Yeung, L., Strumwasser, A. and Victorino, G.P. (2012) Bedside Thoracic Ultrasonography of the Fourth Intercostal Space Reliably Determines Safe Removal of Tube Thoracostomy after Traumatic Injury. Journal of Trauma and Acute Care Surgery, 73, 1570-1575. http://dx.doi.org/10.1097/TA.0b013e318265fc22</mixed-citation></ref><ref id="scirp.58475-ref16"><label>16</label><mixed-citation publication-type="other" xlink:type="simple">Abbasi, H.R., Salahi, R., Paydar, S., Johari, H.G. and Bolandparvaz, S. (2011) Is Routine Chest X-Ray Necessary before Chest Tube Removal? The Journal of Trauma, 70, 523. http://dx.doi.org/10.1097/TA.0b013e318206d2bd</mixed-citation></ref><ref id="scirp.58475-ref17"><label>17</label><mixed-citation publication-type="other" xlink:type="simple">Sperandeo, M., Maggi, M., Catalano, D. and Trovato, G. (2014) No Sliding, No Pneumothorax: Thoracic Ultrasound Is Not an All-Purpose Tool. Journal of Clinical Anesthesia, 26, 425-426. http://dx.doi.org/10.1016/j.jclinane.2014.04.005</mixed-citation></ref><ref id="scirp.58475-ref18"><label>18</label><mixed-citation publication-type="other" xlink:type="simple">Rea, G., D’Amato, M. and Ghittoni, G. (2014) Pitfalls of the Ultrasound Diagnosis of Pneumothorax. The American Journal of Emergency Medicine, 32, 1126-1127. http://dx.doi.org/10.1016/j.ajem.2014.03.053</mixed-citation></ref><ref id="scirp.58475-ref19"><label>19</label><mixed-citation publication-type="other" xlink:type="simple">Cavaliere, F., Zamparelli, R., Soave, M.P., Gargaruti, R., Scapigliati, A. and De Paulis, S. (2014) Ultrasound Artifacts Mimicking Pleural Sliding after Pneumonectomy. Journal of Clinical Anesthesia, 26, 131-135.http://dx.doi.org/10.1016/j.jclinane.2013.09.011</mixed-citation></ref><ref id="scirp.58475-ref20"><label>20</label><mixed-citation publication-type="other" xlink:type="simple">Eisenhuber, E., Schaefer-Prokop, C.M., Prosch, H. and Schima, W. (2012) Bedside Chest Radiography. Respiratory Care, 57, 427-443. http://dx.doi.org/10.4187/respcare.01712</mixed-citation></ref></ref-list></back></article>