Select Journal AA AAD AAR AASoci AAST ABB ABC ABCR ACES ACS ACT AD ADR AE AER AHS AID AiM AIT AJAC AJC AJCC AJCM AJIBM AJMB AJOR AJPS ALAMT ALC ALS AM AMI AMPC ANP APD APE APM ARS ARSci AS ASM BLR CC CE CellBio ChnStd CM CMB CN CRCM CS CSTA CUS CWEEE Detection EMAE ENG EPE ETSN FMAR FNS GEP GIS GM Graphene GSC Health IB ICA IIM IJAA IJAMSC IJCCE IJCM IJCNS IJG IJIDS IJIS IJMNTA IJMPCERO IJNM IJOC IJOHNS InfraMatics JACEN JAMP JASMI JBBS JBCPR JBiSE JBM JBNB JBPC JCC JCDSA JCPT JCT JDAIP JDM JEAS JECTC JEMAA JEP JFCMV JFRM JGIS JHEPGC JHRSS JIBTVA JILSA JIS JMF JMGBND JMMCE JMP JPEE JQIS JSBS JSEA JSEMAT JSIP JSS JSSM JST JTR JTST JTTs JWARP LCE MC ME MI MME MNSMS MPS MR MRC MRI MSA MSCE NJGC NM NR NS OALib OALibJ ODEM OJA OJAB OJAcct OJAnes OJAP OJApo OJAppS OJAPr OJAS OJBD OJBIPHY OJBM OJC OJCB OJCD OJCE OJCM OJD OJDer OJDM OJE OJEE OJEM OJEMD OJEpi OJER OJF OJFD OJG OJGas OJGen OJI OJIC OJIM OJINM OJL OJM OJMC OJMetal OJMH OJMI OJMIP OJML OJMM OJMN OJMP OJMS OJMSi OJN OJNeph OJO OJOG OJOGas OJOp OJOph OJOPM OJOTS OJPathology OJPC OJPChem OJPed OJPM OJPP OJPS OJPsych OJRA OJRad OJRD OJRM OJS OJSS OJSST OJST OJSTA OJTR OJTS OJU OJVM OPJ POS PP PST PSYCH SAR SCD SGRE SM SN SNL Soft SS TEL TI UOAJ VP WET WJA WJCD WJCMP WJCS WJET WJM WJNS WJNSE WJNST WJV WSN YM
More>>
X. C. Wang, “Zero Sequence Current Incre-mental Ratio Method in Small Current Grounding Fault Line Identification,” Vol. 20. Power System Protecetion and control, October 2011, pp.125-129.
has been cited by the following article:
TITLE: Research on Fault-feeder Selection Dvice
AUTHORS: Ziming Zhuo, Haimeng Sun, Haibin Ji
KEYWORDS: Resonance Grounding System; Earthed Fault Feeder Detection; Zero-Sequence Current Increment Method; Zero-sequence Transient Currents
JOURNAL NAME: Energy and Power Engineering, Vol.5 No.4B, November 12, 2013
ABSTRACT: The compensation current of the arc-suppressing coil makes the phase and amplitude of zero-sequence measurement current of the earthed fault feeder to vary. It is very hard to detect the fault feeder by using existing detectors based on single method. In this paper, integrative feeder selection strategy—zero sequence current increment method and the direction of transient current— is put forward. Based on the integrative feeder selection strategy, the design of fault-feeder selection device for one-phase-to ground fault on resonance grounding system is presented. For the purpose of testing and validating the operating principle of the device, the experiment of single-phase-to-ground fault has been carried out on the simulation of 1.2 kV power network. The results from many repeat experiments show that stability of the fault selection device is satisfactory.
Related Articles:
Testing through Fall of Potential with High Current Injection in Grounding System in Transmission Line of 500 kV of Santo Antonio HPS
Carlos Magno B. Araújo, Luiz H. P. C. Trondoli
DOI: 10.4236/oalib.1103323 959 Downloads 1,825 Views Citations
Pub. Date: January 20, 2017
Fault Identification of Power Grid Based on Wide-Area Differential Current and K-Means Clustering
Hao Wu, Qunzhan Li
DOI: 10.4236/epe.2017.94B003 2,314 Downloads 2,673 Views Citations
Pub. Date: April 6, 2017
The Discrimination of Inrush Current from Internal Fault of Power Transformer based on EMD
Fanyuan Zeng, Qianjin Liu, Chao Shi
DOI: 10.4236/epe.2013.54B270 4,472 Downloads 5,646 Views Citations
Pub. Date: November 20, 2013
Reassessment of Permissible Negative Sequence Current for Power Plant Operation of Taipower
Ping-heng Ho, Chi-jui Wu, Chung-liang Chang, Yuin-hong Liu
DOI: 10.4236/epe.2010.24039 5,449 Downloads 9,471 Views Citations
Pub. Date: November 26, 2010
Research on DC Fault of Multi-Terminal Direct Current System
S. Y. Fan, J. Liu, E. M. Bian, H. T. Xu, C. L. Kang
DOI: 10.4236/epe.2017.94B081 2,577 Downloads 2,995 Views Citations
Pub. Date: April 17, 2017