Article citationsMore>>
Johns, J., Gold, H., Leinbach, R., Yasuda, T., Gimple, L., Werner, W., Finkelstein, D., Newell, J., Ziskind, A. and Collen, D. (1988) Prevention of coronary artery reocclusion and reduction in late coronary artery stenosis after thrombolytic therapy in patients with acute myocardial infarction. A randomized study of maintenance infusion of recombinant human tissue-type plasminogen activator. Circulation, 78, 546-556.
has been cited by the following article:
-
TITLE:
Enzyme electrophoresis method in analysis of active components of haemostasis system
AUTHORS:
Ludmila Ostapchenko, Oleksiy Savchuk, Nataliia Burlova-Vasilieva
KEYWORDS:
Substrate-Containing Electrophoresis; Enzyme Electrophoresis; Haemostasis; Proteins Activity; Proteins Identification
JOURNAL NAME:
Advances in Bioscience and Biotechnology,
Vol.2 No.1,
February
24,
2011
ABSTRACT: The novel modifications of substrate-containing sodium dodecyl sulfate-polyacrylamide gel electrophoresis that can be used for the detection of proteases and its activators are reported. The protease/activator samples were separated on a protein substrate-SDS-polyacrylamide gel. To detect plasminogen activators fibrinogen and Glu-plasminogen were incorporated into the SDS-PAG followed by 1 h incubation at 37?C in thrombin solution (1 NIH/ml). After electrophoresis the gel was stained according to the standard protocol. To detect fibrin-unspecific plasminogen activators from snake venom incubation in thrombin solution was substituted for 12 h incubation in 50 mM Tris-HCl (pH 7.4). To detect fibrinogen-degrading enzymes fibrinogen-containing gel was used. Activity of protease/activator was visualized in the gel as clear bands against the dark background. These new techniques offer several advantages including determination of the quantity and activity of t-PA and urokinase, however cannot be recommended for precise quantification of activators; the total procedure is quite quick and simple; method is convenient tool for detection of novel protein-protein interactions in haemostasis system; the sensitivity of the method is ≤0.01 IU per track.
Related Articles:
-
M. Aithoussa, A. Abdou, N. Atmani, M. Bamous, Y. Moutakiallah, F. Nya, A. Seghrouchni, A. Hatim, Y. Elbekkali, A. Boulahya
-
Adham I. Ahmed
-
Deepak Puri, Nidhi Puri
-
Hailin Wang, Chunyu Cao, Lianqiang Hui, Ting Liu, Yanli Wang, Shuangrong Gao, Yi Zhang, Ran Hao, Chun Li, Chen Zang
-
Animesh Mishra, Tony Ete, Rinchin Dorjee, Pravin Kumar Jha, Amit Malviya, Gaurav Kavi