TITLE:
Comparison of Calculated Fit and Experimental Calculations of Average Dose Deposited in Aluminum by High Energy Electron Beams
AUTHORS:
Mohammad Farnush
KEYWORDS:
Calculated Fit, Average Dose, Aluminum, High Energy Electron Beams
JOURNAL NAME:
Journal of Modern Physics,
Vol.8 No.5,
April
17,
2017
ABSTRACT: This paper presents the formalism for absorbed dose determination to Aluminum in high-energy electron beams using Rhodotron accelerator. Depth dose curve for Aluminum at electron energy of 10 MeV was calculated. The calculated curve in the model as a function of the depth is compared to the experimental. The agreement of the final results remained well within the expected acceptable range. The calculated values of dose-to-Aluminum are completely fit with the measured values in the range of 0.07% for electron energy of 10 MeV.