Ocular Response Analyzer to Assess Age-Related Biomechanical Characteristics of the Cornea in a Taiwanese Population

Abstract

Purpose: To investigate biomechanical properties of the cornea as measured using a Reichert ocular response analyzer (ORA) in a Taiwanese population. Methods: Basic demographic data were recorded for 1875 Taiwanese subjects. Corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CCT), Goldmann-equivalent intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc) were measured with an ORA. Descriptive statistics and multiple regression analyses were used to assess and compare relevant factors of the CRF and CH. Results: In total, 1817 eyes were included in this study. The mean patient age was 21.4 ± 17.01 years. The mean (±SD) CH and CRF values were 10.6 ± 1.81 and 10.6 ± 1.99 mmHg, respectively. The mean CCT was 560.4 ± 38.53 μm. CH was correlated with IOPcc, CRF, and CCT. In the multiple linear-regression model, CH was associated with and affected by IOPcc, CRF, and CCT. In another multiple linear-regression model, CRF was associated with and affected by IOPcc, CH, and CCT. Conclusions: Measuring biomechanical properties by Reichert ORA, we found that CH and CRF values of a Taiwanese population were similar to those other Asian populations and other races. Our findings provided fundamental data of CH and CRF in a Taiwanese (ethic Chinese) and also Asian population.

Share and Cite:

Wang, T. , Lee, S. , Hsu, W. , Chang, D. and Wang, I. (2014) Ocular Response Analyzer to Assess Age-Related Biomechanical Characteristics of the Cornea in a Taiwanese Population. International Journal of Clinical Medicine, 5, 650-656. doi: 10.4236/ijcm.2014.512089.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Chui, W.S., Lam, A., Chen, D. and Chiu, R. (2008) The Influence OF Corneal Properties on Rebound Tonometry. Ophthalmology, 115, 80-84.
http://dx.doi.org/10.1016/j.ophtha.2007.03.061
[2] Luce, D.A. (2005) Determining in Vivo Biomechanical Properties of the Cornea with an Ocular Response Analyzer. Journal of Cataract & Refractive Surgery, 31, 156-162.
http://dx.doi.org/10.1016/j.jcrs.2004.10.044
[3] Kirwan, C., O’Malley, D. and O’Keefe, M. (2008) Corneal Hysteresis and Corneal Resistance Factor in Keratoectasia: Findings Using the Reichert Ocular Response Analyzer. Ophthalmologica, 222, 334-337.
http://dx.doi.org/10.1159/000145333
[4] Shah, S., Laiquzzaman, M., Cunliffe, I. and Mantry, S. (2006) The Use of the Reichert Ocular Response Analyser to Establish the Relationship between Ocular Hysteresis, Corneal Resistance Factor and Central Corneal Thickness in Normal Eyes. Contact Lens & Anterior Eye, 29, 257-262.
http://dx.doi.org/10.1016/j.clae.2006.09.006
[5] Kirwan, C., O’Keefe, M. and Lanigan, B. (2006) Corneal Hysteresis and Intraocular Pressure Measurement in Children Using the Reichert Ocular Response Analyzer. American Journal of Ophthalmology, 142, 990-992.
http://dx.doi.org/10.1016/j.ajo.2006.07.058
[6] Lim, L., Gazzard, G., Chan, Y.H., Fong, A., Kotecha, A., Sim, E.L., et al. (2008) Cornea Biomechanical Characteristics and Their Correlates with Refractive Error in Singaporean Children. Investigative Ophthalmology & Visual Science, 49, 3852-3857.
http://dx.doi.org/10.1167/iovs.07-1670
[7] Elsheikh, A., Wang, D., Rama, P., Campanelli, M. and Garway-Heath, D. (2008) Experimental Assessment of Human Corneal Hysteresis. Current Eye Research, 33, 205-213.
http://dx.doi.org/10.1080/02713680701882519
[8] Kotecha, A., Elsheikh, A., Roberts, C.R., Zhu, H. and Garway-Heath, D.F. (2006) Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response Analyzer. Investigative Ophthalmology & Visual Science, 47, 5337-5347.
http://dx.doi.org/10.1167/iovs.06-0557
[9] Kirwan, C. and O’Keefe, M. (2008) Corneal Hysteresis Using the Reichert Ocular Response Analyser: Findings Pre- and Post-LASIK and LASEK. Acta Ophthalmologica, 86, 215-218.
http://dx.doi.org/10.1111/j.1600-0420.2007.01023.x
[10] Ortiz, D., Pinero, D., Shabayek, M.H., Arnalich-Montiel, F. and Alio, J.L. (2007) Corneal Biomechanical Properties in Normal, Post-Laser in Situ Keratomileusis, and Keratoconic Eyes. Journal of Cataract & Refractive Surgery, 33, 1371-1375.
http://dx.doi.org/10.1016/j.jcrs.2007.04.021
[11] Kamiya, K., Shimizu, K. and Ohmoto, F. (2009) Effect of Aging on Corneal Biomechanical Parameters Using the Ocular Response Analyzer. Journal of Refractive Surgery, 25, 888-893.
http://dx.doi.org/10.3928/1081597X-20090917-10
[12] Narayanaswamy, A., Chung, R.S., Wu, R.Y., Park, J., Wong, W.L., Saw, S.M., et al. (2011) Determinants of Corneal Biomechanical Properties in an adult Chinese Population. Ophthalmology, 118, 1253-1259.
[13] Pepose, J.S., Feigenbaum, S.K., Qazi, M.A., Sanderson, J.P. and Roberts, C.J. (2007) Changes in Corneal Biomechanics and Intraocular Pressure Following LASIK Using Static, Dynamic, and Noncontact Tonometry. American Journal of Ophthalmology, 143, 39-47.
http://dx.doi.org/10.1016/j.ajo.2006.09.036
[14] Lu, F., Xu, S., Qu, J., Shen, M., Wang, X., Fang, H., et al. (2007) Central Corneal Thickness and Corneal Hysteresis During Corneal Swelling Induced by Contact Lens Wear with Eye Closure. American Journal of Ophthalmology, 143, 616-622.
http://dx.doi.org/10.1016/j.ajo.2006.12.031
[15] Jorge, J.M., Gonzalez-Meijome, J.M., Queiros, A., Fernandes, P. and Parafita, M.A. (2008) Correlations between Corneal Biomechanical Properties Measured with the Ocular Response Analyzer and ICare Rebound Tonometry. Journal of Glaucoma, 17, 442-448.
http://dx.doi.org/10.1097/IJG.0b013e31815f52b8
[16] Shen, M., Wang, J., Qu, J., Xu, S., Wang, X., Fang, H., et al. (2008) Diurnal Variation of Ocular Hysteresis, Corneal Thickness, and Intraocular Pressure. Optometry and Vision Science, 85, 1185-1192.
http://dx.doi.org/10.1097/OPX.0b013e31818e8abe
[17] Avetisov, S.E., Novikov, I.A., Bubnova, I.A., Antonov, A.A. and Siplivyi, V.I. (2010) Determination of Corneal Elasticity Coefficient Using the ORA Database. Journal of Refractive Surgery, 26, 520-524.

Copyright © 2023 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.