Do the Right Patients use the Ambulance Service in South-Eastern Finland?

Abstract

Background: Several Emergency Medical Systems use a criteria-based prioritization system for ambulance response. The emergency medical priority dispatching of ambulances was introduced in the 1980s. In a system of this kind, the operators at the medical emergency dispatch centers have to assess the patients’ symptoms and the need for ambulance response. The prioritization of the ambulance response is based on the seriousness of the patient’s symptoms, his/her current condition and, in the case of trauma, the trauma mechanism. The priority system is supposed to optimize the use of the ambulance service and to match and meet the patients’ needs with an adequate response from the ambulances. The aim of this study was to describe the dispatching and utilization of the ambulance service in a part of Finland. Results: There was a substantial divergence between the initial priority assigned and the patients’ medical status at the scene. The ambulance staff confirmed the need for ambulance transport for 65% of all the patients who were assigned an ambulance by the dispatch center. Conclusions: Using a criteria-based dispatch protocol, the dispatch operator works with a wider safety margin in the priority assessments for ambulance response than was actually confirmed by the ambulance personnel at the scene. In this sample, there may be some overuse of the ambulance service. According to the assessments made by the ambulance staff, 35% of the patients did not require ambulance transport. The emergency system has to accept and work with safety margins. At the same time, there must be a balance between a safety margin and a waste of limited resources.

Share and Cite:

B. Suserud, L. Beillon, I. Karlberg, J. Pappinen, M. Castren and J. Herlitz, "Do the Right Patients use the Ambulance Service in South-Eastern Finland?," International Journal of Clinical Medicine, Vol. 2 No. 5, 2011, pp. 544-549. doi: 10.4236/ijcm.2011.25089.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] J. J. Clawson, “Hauert Dispaching Life Support—Establishing Standards That Work,” Journal of Emergency Medicine Service, Vol. 154, 1990, pp. 82-88.
[2] L. L. Culley, D. K. Henwood, J. J. Clark, M. S. Eisenberg and C. Horton, “Increasing the Efficiency of Emergency Medical Services by Using Criteria Based Dispatch,” Annual of Emergency Medicine, Vol. 24, No. 5, 1994, pp. 867- 872. doi:10.1016/S0196-0644(54)00223-5
[3] L. Hjalte, B. O. Suserud, J. Herlitz and I. Karlberg, “Initial Emergency Medical Dispatching and Prehospital Need Assessment. A Prospective Study of the Swedish Ambulance Service,” European Journal of Emergency Medicine, Vol. 14, No. 3, 2007, pp. 134-156. doi:10.1097/MEJ.0b013e32801464cf
[4] M. W. Cooke, “The Use of Criteria Based Dispatch in the Prioritisation of 999 Emergency Ambulance Calls,” Department of primary care & General Practice, Faculty of Medicine, The University of Birmingham, Birmingham, 2001.
[5] G. E. Michael and K. A. Sporer, “Validation of Low-Acuity Emergency Medical Services Dispatch Codes,” Prehospital Emergency Care, Vol. 9, No. 4, 2005, pp. 429-433. doi:10.1080/10903120500255875
[6] A. Bang, P. O. Ortgren, J. Herlitz and P. Warborg, “Dispatcher-Assisted Telephone CPR: A Qualitative Study Exploring How Dispatchers Perceive Their Experience,” Resuscitation, Vol. 53, No. 2, 2002, pp. 135-151. doi:10.1016/S0300-9572(01)00508-1
[7] A. Langhelle, H. M. Lossius, T. Silfvast, H. M. Bjornsson, F. Lippert, A. Ersson and E. Soreide, “International EMS System: The Nordic Countries,” Resuscitation, Vol. 61, No. 1, 2004, pp. 9-21. doi:10.1016/j.resuscitation.2003.12.008
[8] L. M. Beillon, B. O. Suserud, I. Karlberg and J. Herlitz, “Does Ambulance Use Differ between Geographic Areas? A Survey of Ambulance Use in Sparsely and Densely Populated Areas,” The American Journal of Emergency Medicine, Vol. 27, No. 2, 2009, pp. 202-211. doi:10.1016/j.ajem.2008.01.012

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.