[1]
|
Ussenko, L.V., Tsarev, A.V. and Leschenko, Y.A. (2006) Naum L Gurvich: A Pioneer of Defibrillation. Resuscitation, 70, 170-172. http://dx.doi.org/10.1016/j.resuscitation.2006.05.005
|
[2]
|
Vostrikov, V.A. and Gorbunov, B.B. (2012) Rus-sian History of Cardiac Defibrillation. General Reanimatology, 8, 63-68. (In Russian) http://dx.doi.org/10.15360/1813-9779-2012-3-63
|
[3]
|
Gurvich, N.L. and Makarychev, V.A. (1967) Defibrillation of the Heart with Biphasic Electric Impulsation. Kardiologiia, 7, 109-112. (In Russian) http://defibrillation.ru/download/Kardiologiya,1967,7,109-112.pdf
|
[4]
|
Negovsky, V.A., Gurvich, N.L., Tabak, V.Y. and Bogushevich, M.S. (1973) The Nature of Electric Defibrillation of the Heart. Resuscitation, 2, 255-259. http://dx.doi.org/10.1016/0300-9572(73)90030-0
|
[5]
|
Venin, I.V., Gurvich, N.L., Olifer, B.M., Pasichnik, T.V., Savelyev, V.I., Sidorov, V.N., Tsukerman, B.M. and Sherman, A.M. (1970) Defibrillator. USSR Patent No. 258526. (In Russian) http://defibrillation.ru/download/SU_258526_A1.pdf
|
[6]
|
Gurvich, N.L., Tabak, V.Y., Bogushevich, M.S., Venin, I.V. and Makarychev, V.A. (1971) Biphasic Impulse Heart Defibrillation under Experimental and Clinical Conditions. Kardiologiia, 11, 126-130. (In Russian) http://defibrillation.ru/download/Kardiologiya,1971,8,126-130.pdf
|
[7]
|
Vostrikov, V.A. and Venin, I.V. (2000) Comparison of Efficiency of Biphasic Sinusoidal Waveforms with Different Amplitude of Second Phases in Transthoracic Defibrillation of Dogs. Resuscitation, 45, S6, P-17. http://defibrillation.ru/download/Resuscitation,2000,45%281%29,S6.pdf
|
[8]
|
Venin, I.V., Gurvich, N.L., Tabak, V.Y. and Tsukerman, B.M. (1974) OST64-1-116-74. Defibrillators. General Specifications. Ministerstvo medicinskoyj promihshlennosti, Moscow. (In Russian) http://defibrillation.ru/download/OST64-1-116-74.pdf
|
[9]
|
Negovsky, V.A., Smerdov, A.A., Tabak, V.Y., Venin, I.V. and Bogushevich, M.S. (1980) Criteria of Efficiency and Safety of Defibrillating Impulse, Resuscitation, 8, 53-67. http://dx.doi.org/10.1016/0300-9572(80)90006-4
|
[10]
|
O’Dowd, W.J. (1983) Defib-rillator Design and Development—A Review. Journal of Medical Engineering & Technology, 7, 5-15. http://dx.doi.org/10.3109/03091908309041218
|
[11]
|
Schuder, J.C., McDaniel, W.C., Stoekle, H. and Yerkovich, D. (1988) Comparison of Effectiveness of Relay-Switched, One-Cycle Quasisinusoidal Waveform with Critically Damped Sinusoid Waveform in Transthoracic Defibrillation of 100 kg Calves. Medical Instrumentation, 22, 281-285. http://defibrillation.ru/download/Medical_Instrumentation,1988,v22,No6,281-285.pdf
|
[12]
|
Vostrikov, V.A., Holin, P.V. and Razumov, K.V. (1994) Efficiency of Biphasic Waveforms in Transthoracic Ventricular Defibrillation of Man. American Heart Journal, 128, 638. http://defibrillation.ru/download/American_Heart_Journal,1994,v128,3,638.pdf
|
[13]
|
Vostrikov, V.A., Holin, P.V. and Razumov, K.V. (1998) Effectiveness of Quasi-Sinusoidal Biphasic Waveform in Transthoracic Ventricular Defibrillation of Humans. Resuscitation, 37, S42, O-16. http://defibrillation.ru/download/Resuscitation,1998,v37,2,S42.pdf
|
[14]
|
Vostrikov, V.A., Holin, P.V. and Razumov, K.V. (1999) Transthoracic Ventricular Defibrillation: Efficacy and Safety of Biphasic Sinusoidal Pulse. Anesteziologiya i reanimatologiya, 1, 44-47. (In Russian) http://defibrillation.ru/download/Anesteziologiya_i_reanimatologiya,1999,1,44-47.pdf
|
[15]
|
Greene, H.L., DiMarco, J.P., Kudenchuk, P.J., Scheinman, M.M., Tang, A.S., Reiter, M.J., Echt, D.S., Chapman, P.D., Jazayeri, M.R., Chapman, F.W., Ahmed, M., Johnson, J.L. and Niskanen, R.A. (1995) Comparison of Monophasic and Biphasic Defibrillating Pulse Waveforms for Transthoracic Cardioversion. The American Journal of Cardiology, 75, 1135-1139. http://dx.doi.org/10.1016/S0002-9149(99)80745-0
|
[16]
|
Cummins, R.O., Hazinski, M.F., Kerber, R.E., Kudenchuk, P., Becker, L., Nichol, G., Malanga, B., Aufderheide, T.P., Stapleton, E.M., Kern, K., Ornato, J.P., Sanders, A., Valenzuela, T. and Eisenberg, M. (1998) Low-Energy Biphasic Waveform Defibrillation: Evidence-Based Review Applied to Emergency Cardiovascular Care Guidelines: A Statement for Healthcare Professionals from the American Heart Association Committee on Emergency Cardiovascular Care and the Subcommittees on Basic Life Support, Advanced Cardiac Life Support, and Pediatric Resuscitation. Circulation, 97, 1658. http://dx.doi.org/10.1161/01.CIR.97.16.1654
|
[17]
|
Ristagno, G., Yu, T., Quan, W., Freeman, G. and Li, Y. (2013) Current Is Better than Energy as Predictor of Success for Biphasic Defibrillatory Shocks in a Porcine Model of Ventricular Fibrillation. Resuscitation, 84, 678-683. http://dx.doi.org/10.1016/j.resuscitation.2012.09.029
|
[18]
|
Vostrikov, V.A., Razumov, K.V., Venin, I.V. and Arutyunov, V. (2004) Сurrent Requirements for In-Hospital Termination of Ventricular Fibrillation. Resuscitation, 62, 366, PO22. http://dx.doi.org/10.1016/j.resuscitation.2004.06.004
|
[19]
|
Vostrikov, V.A., Gorbunov, B.B. and Gusev, A.N. (2014) Computer Simulation of Cardiomyocyte Membrane Exposure to First Phase Bipolar Defibrillation Impulses. General Reanimatology, 10, 29-32. http://dx.doi.org/10.15360/1813-9779-2014-1-25-32
|