Measure the Bulk Etch Rate Using the Time-Diameter Method

Abstract

The present work measured the bulk etch rate (VB ) of solid state nuclear track detector by taking the diameter time measurement of alpha particle in CR-39 detector. The values of the track diameter have been found by using TRACK-TEST program from Yu et al. function and Brun et al. function with different energies of alpha particles. The results showed that the time-diameter (t-d) method gave good results of the bulk etch rate (VB ) and these values were (1.705 and 1.72) μm·hr-1. They showed good agreement with the values measured by using the other methods, and it was a simple method because it required getting diameters of the tracks in the detector with the etching time.

Share and Cite:

Ahmed, H. , Ahmad, A. and Mohammed, A. (2015) Measure the Bulk Etch Rate Using the Time-Diameter Method. Materials Sciences and Applications, 6, 286-291. doi: 10.4236/msa.2015.64034.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Fleischer, R.L., Price, P.B. and Walker, R.M. (1975) Nuclear Tracks in Solids.
[2] Jain, R.K., Kumar, A., Chakraborty, R.N. and Nayak, B.K. (2014) Irradiation Effect of 60Co Gamma Rays on Bulk Etch Rate, Track Etch Rate and Activation Energy of CR-39 Solid State Nuclear Track Detector. Proceedings of the DAE Symposium on Nuclear Physics, 59, 432-433.
[3] Hafez, A.F. and Somogyi, G. (1986) Determination of Radon and Thoron Permeability through Some Plastics by Track Technique. International Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements, 12, 697.
http://dx.doi.org/10.1016/1359-0189(86)90682-5
[4] Leonardi, F., Caresana, M., d’Alessandro, M., Mishra, R., Tonnarini, S., Trevisi, R. and Veschetti, M. (2009) An Extended Study of the Etching Characteristics of CR-39 Detectors. Radiation Measurements, 44, 787-790.
http://dx.doi.org/10.1016/j.radmeas.2009.10.026
[5] Chavan, V., Kalsi, P.C. and Mhatre, A. (2011) The Etching, Optical and Thermal Response of a Newly Developed Nuclear Track Detector Called NADAC-ADC Copolymer to Gamma-Irradiation. Journal of Radioanalytical and Nuclear Chemistry, 87, 273-276.
http://dx.doi.org/10.1007/s10967-010-0673-7
[6] Durrani, S.A. and Bull, R.K. (1987) Solid State Nuclear Track Detection. Pergamon Press, Oxford.
[7] Nikezic, D. and Janicijevic, A. (2002) Bulk Etching Rate of LR-115 Detectors. Applied Radiation and Isotopes, 57, 275-278.
http://dx.doi.org/10.1016/S0969-8043(02)00109-4
[8] Salman, T.M. (2010) The Effect of Stirring and Interruption on the Etching Characteristic of cr-39 Track Detector. Journal of Basrah Researches (Sciences), 36, 17-21.
[9] Manzoor, S. (2006) Nuclear Track Detectors for Environmental Studies and Radiation Monitoring. Physical Department, University of Bologna, Bologna.
[10] Balestra, S., Cozzi, M., Giacomelli, G., Giacomelli, R., Giorgini, M., Kumar, A., Mandrioli, G., Manzoor, S., Margiotta, A.R., Medinaceli, E., Partizii, L., Popa, V., Qureshi, I.E., Rana, M.A., Sirri, G., Spurio, M., Togo, V. and Valieri, C. (2007) Bulk Etch Rate Measurements and Calibrations of Plastic Nuclear Track Detectors. Nuclear Instruments and Methods in Physics Research, B254, 254-258. http://dx.doi.org/10.1016/j.nimb.2006.11.056
[11] Nikezic, D. and Yu, K.N. (2006) Computer Program TRACK_TEST for Calculating Parameters and Plotting Profiles for Etch Pits in Nuclear Track Materials. Computer Physics Communications, 174, 160-165.
http://dx.doi.org/10.1016/j.cpc.2005.09.011
[12] Yu, K.N., Ng, F.M.F. and Nikeic, D. (2005) Measuring Depths of Sub-Micron Tracks in a CR-39 Detector from Replicas Using Atomic Force Microscopy. Radiation Measurements, 40, 380-383.
http://dx.doi.org/10.1016/j.radmeas.2005.03.011
[13] Brun, C., Fromm, M., Jouffroy, M., Meyer, P., Groetz, J.E., Abel, F., Chambaudet, A., Dorschel, B., Hermsdorf, D., Bretschneider, R., Kadner, K. and Kunhe, H. (1999) Inter Comparative Study of the Detection Characteristics of the CR-39 SSNTD for Light Ions: Present Status of the Besancon-Dresden Approaches. Radiation Measurement, 31, 89- 98.
http://dx.doi.org/10.1016/S1350-4487(99)00102-X
[14] Al-Nia’emi, S.H.S. and Kasim, Y.Y. (2013) Determination of the Bulk Etch Rate of the Nuclear Track Detector CR-39 Using Le-D Method. Journal of Physics, 6, 17-25.
[15] Yu, K.N., Ng, F.M.F. and Nikeic, D. (2005) Measuring Depths of Sub-Micron Tracks in a CR-39 Detector from Replicas Using Atomic Force Microscopy. Radiation Measurements, 40, 380-383.
http://dx.doi.org/10.1016/j.radmeas.2005.03.011
[16] Fromm, M., Vaginay, F., Meesen, G., Chambaudet, A. and Poffijn, A. (2003) Watching at the Correlation between the Specific Track-Etch Rate and the Primary Physical Parameters of the Swift Ion Interaction with the CR-39. Radiation Measurements, 36, 93-98.
http://dx.doi.org/10.1016/S1350-4487(03)00101-X

Copyright © 2023 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.