Structural Damage Localization by Linear Technique of Acoustic Emission

Abstract Full-Text HTML XML Download Download as PDF (Size:2854KB) PP. 425-432
DOI: 10.4236/ojfd.2014.45032    2,765 Downloads   3,148 Views   Citations

ABSTRACT

Linear source location of acoustic emission (AE) technique has been applied in the present paper for finding the source of material damage under fatigue loading. A plate type structure of ductile cast iron has been used to undergo fatigue damage in a servopulsing machine in the experiment. AE sensors were attached to the specimen for getting the time delay of AE signal propagations through the specimen. After receiving the time delay data of AE signals due to the damage initiation in the material for the provided fatigue loads, linear source location algorithm has been applied and the crack positions are identified. Before applying the technique, a series of pencil lead breaks (PLBs) tests have been conducted upon a ductile cast iron plate of same dimension for verifying the applied algorithm. According to the PLBs varification, the failure location of ductile cast iron (pearlite type) due to the fatigue loading has been characterized. In both experiments, the active ability of the proposed technique for source location of structural damage has been identified clearly and successfully.

Conflicts of Interest

The authors declare no conflicts of interest.

Cite this paper

Khan, M. , Sunichi, N. and Hasan, M. (2014) Structural Damage Localization by Linear Technique of Acoustic Emission. Open Journal of Fluid Dynamics, 4, 425-432. doi: 10.4236/ojfd.2014.45032.

References

[1] Abe, S. (2006) Acoustic Emission Testing. Nondestructive Testing Series I, Japan Society for Non-Destructive Inspection, 4-22. (In Japanese)
[2] Dawson, B. (1976) Vibration Condition Monitoring Techniques for Rotating Machinery. The Shock and Vibration Digest (London), 8, 3.
http://dx.doi.org/10.1177/058310247600801203
[3] Wilcox, P.D., Lee, C.K., Scholey, J.J., Friswell, M.I., Wisnom, M.R. and Drinkwater, B.W. (2006) Quantitative Structural Health Monitoring Using Acoustic Emission. SPIE, 6173, 1-10.
[4] Meyendorf, N., Frankenstein, B. and Schubert, L. (2012) Structural Health Monitoring for Aircraft, Ground Transportation Vehicles, Wind Turbines and Pipes-Prognosis. 18th World Conference on Nondestructive Testing, Durban, 16- 20 April 2012.
[5] Finlayson, R.D., Friesel, M., Carlos, Cole, P. and Lenain, J.C. (2001) Health Monitoring of Aerospace Structures with Acoustic Emission and Acousto-Ultrasonics. Insight, 43, 1-4.
[6] Beghi, M.G. (2013) Modeling and Measurement for Acoustic Wave and for Acoustic Microdevices. In Tech.
[7] Theobald, P. and Dar, F. (2006) AE Sensor Calibration for Out-of-Plane and In-Plane Displacement Sensitivity. Journal of Advanced Material Research, 13, 91-98.
http://dx.doi.org/10.4028/www.scientific.net/AMR.13-14.91
[8] Yoshioka, T. and Fujiwara, T. (1982) A New Acoustic Emission Source Locating System for the Study of Rolling Contact Fatigue. Wear, 81, 183-186.
http://dx.doi.org/10.1016/0043-1648(82)90314-3
[9] Baxter, M.G., Pullin, R., Holford, K.M. and Evans, S.L. (2007) Delta T Source Location for Acoustic Emission. Mechanical Systems and Signal Processing, 2007, 1512-1520.
http://dx.doi.org/10.1016/j.ymssp.2006.05.003
[10] Jonathan, J.S., Paul, D.W. and Michael, R.W. (2008) Two-Dimensional Source Location Techniques for Large Composite Plates. Proceedings, EWGAE 2008, 160-165.

  