[1]
|
Walton, T.R. (2002) An up to 15-year longitudinal study of 515 metal-ceramic FPDs: Part 1. Outcome. International Journal of Prosthodontics, 15, 439-445.
|
[2]
|
Ozcan, M. (2003) Fracture reasons in ceramic-fusedto-metal restorations. Journal of Oral Rehabilitation, 30, 265-269. http://dx.doi.org/10.1046/j.1365-2842.2003.01038.x
|
[3]
|
Singer, A. and Serfaty, V. (1996) Cement-retained implant-supported fixed partial dentures: A 6-month to 3-year follow-up. International Journal of Oral & Maxillofacial Implants, 11, 645-649.
|
[4]
|
Strub, J.R., Stiffler, S. and Scharer, P. (1988) Cause of failure following oral rehabilitation: Biological versus technical factors. Quintessence International, 19, 215-222.
|
[5]
|
Walton, J.N., Gardner, F.M. and Agar J.R. (1986) A survey of crown and fixed partial denture failures: length of service and reasons for replacement. Journal of Prosthetic Dentistry, 56, 416-421. http://dx.doi.org/10.1016/0022-3913(86)90379-3
|
[6]
|
Bragger, U., Karoussis, I., Persson, R., et al. (2005) Technical and biological complications/failures with single crowns and fixed partial dentures on implants: A 10-year prospective cohort study. Clinical Oral Implants Research, 16, 326-334. http://dx.doi.org/10.1111/j.1600-0501.2005.01105.x
|
[7]
|
Goodacre, C.J., Bernal, G., Rungcharassaeng, K., et al. (2003) Clinical complications in fixed prosthodontics. Journal of Prosthetic Dentistry, 90, 31-41. http://dx.doi.org/10.1016/S0022-3913(03)00214-2
|
[8]
|
Zarb, G.A. and Smith, A. (1990) The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered. Journal of Prosthetic Dentistry, 64, 185-194. http://dx.doi.org/10.1016/0022-3913(90)90177-E
|
[9]
|
Ekfeldt, A., Carlsson, G.E. and Borjesson G. (1994) Clinical evaluation of single-tooth restorations supported by osseointegrated implants: A retrospective study. International Journal of Oral & Maxillofacial Implants, 9, 179-183.
|
[10]
|
Warpeha, W.S. and Goodkind, R.J. (1976) Design and technique variables affecting fracture resistance of metalceramic restorations. Journal of Prosthetic Dentistry, 35, 291-298. http://dx.doi.org/10.1016/0022-3913(76)90253-5
|
[11]
|
Anthony, D.H., Burnett, A.P., Smith, D.L., et al. (1970) Shear test for measuring bonding in cast gold alloy-porcelain composites. Journal of Dental Research, 49, 27-33. http://dx.doi.org/10.1177/00220345700490012601
|
[12]
|
Craig, R.G. and Powers, J.M. (2002) Restorative dental materials. 11th edition. Mosby, St. Louis, 580.
|
[13]
|
Kelly, M., Asgar, K. and O’Brien, W.J. (1969) Tensile strength determination of the interface between porcelain fused to gold. Journal of Biomedical Materials Research, 3, 403-408. http://dx.doi.org/10.1002/jbm.820030302
|
[14]
|
Shell, J.S. and Nielsen, J.P. (1962) Study of the bond between gold alloys and porcelain. Journal of Dental Research, 41, 1424-1437. http://dx.doi.org/10.1177/00220345620410062101
|
[15]
|
Riley, E.J. (1977) Ceramo-metal restoration. State of the science. Dental Clinics of North America, 21, 669-682.
|
[16]
|
Shillingburg, H.T., Hobo, S., Whitsett, L.D., Jacobi, R. and Brackett, S.E. (1997) Fundamentals of fixed prosthodontics, 3rd edition, Quintessence Publishing Co, Chicago, 89-94.
|
[17]
|
Caputo, A.A. and Standlee, J.P. (1987) Biomechanics in clinical dentistry. Quintessence Publishing Co., Inc., Chicago, 123-149.
|
[18]
|
Palmqvist, S. and Soderfeldt, B. (1994) Multivariate analyses of factors influencing the longevity of fixed partial dentures, retainers, and abutments. Journal of Prosthetic Dentistry, 71, 245-250. http://dx.doi.org/10.1016/0022-3913(94)90462-6
|
[19]
|
Tuccillo, J.J. and Nielsen, J.P. (1972) Shear stress measurements at a dental porcelain-gold bond interface. Journal of Dental Research, 51, 626-633. http://dx.doi.org/10.1177/00220345720510026301
|
[20]
|
Pang, I.C., Gilbert, J.L., Chai, J., et al. (1995) Bonding characteristics of low-fusing porcelain bonded to pure titanium and palladium-copper alloy. Journal of Prosthetic Dentistry, 73, 17-25. http://dx.doi.org/10.1016/S0022-3913(05)80267-7
|
[21]
|
Craig, R.G. (1993) Restorative dental materials. 9th ed. Mosby, St. Louis, 492.
|
[22]
|
Evans, D., Barghi, N., Malloy C, et al. (1990) The influence of condensation method on porosity and body porcelain. Journal of Prosthetic Dentistry, 63, 380-389. http://dx.doi.org/10.1016/0022-3913(90)90224-Z
|
[23]
|
Ritter, J.E. (1995) Predicting lifetimes of materials and material structures. Dental Materials, 11, 142-146. http://dx.doi.org/10.1016/0109-5641(95)80050-6
|
[24]
|
Nielsen, J.P. and Tuccillo, J.J. (1972) Calculations of interfacial stress in dental porcelain bonded to gold alloy substrate. Journal of Dental Research, 51, 1043-47. http://dx.doi.org/10.1177/00220345720510040901
|
[25]
|
Barreto, M.T. (1984) Failure in ceramometal fixed restorations. Journal of Prosthetic Dentistry, 51, 186-189. http://dx.doi.org/10.1016/0022-3913(84)90256-7
|
[26]
|
Campbell, S.D. (1989) A comparative strength study of metal ceramic and all-ceramic esthetic materials: Modulus of rupture. Journal of Prosthetic Dentistry, 62, 476-479. http://dx.doi.org/10.1016/0022-3913(89)90184-4
|
[27]
|
Suansuwan, S. and Swain, M. (1999) New approach for evaluating metal porcelain interfacial bonding. International Journal of Prosthodontics, 12, 547-552.
|
[28]
|
Reuter, J.E. and Brose, M.O. (1984) Failures in full crown retained dental bridges. British Dental Journal, 157, 61-63. http://dx.doi.org/10.1038/sj.bdj.4805411
|
[29]
|
Rosenstiel, S.F., Land, M.F. and Fujimoto, J. (2001) Contemporary fixed prosthodontics, 3rd edition. Mosby, St Louis, 73.
|
[30]
|
Burke, F.J. (1996) Fracture resistance of teeth restored with dentin-bonded crowns: the effect of increased tooth preparation. Quintessence International, 27, 115-121.
|
[31]
|
Ban, S. and Anusavice, K.J. (1990) Influence of test method on failure stress of brittle dental materials. Journal of Dental Research, 69, 1791-1799. http://dx.doi.org/10.1177/00220345900690120201
|
[32]
|
Llobell, A., Nichlls, J.I., Kois, J.C., et al. (1992) Fatigue life of porcelain repair systems. International Journal of Prosthodontics, 5, 205-213.
|
[33]
|
Anusavice, K.J. and Zhang, N.Z. (1998) Chemical durability of Dicor and fluorocanasite-based glass-ceramics. Journal of Dental Research, 77, 1553-1559. http://dx.doi.org/10.1177/00220345980770071101
|
[34]
|
White, S.N., Li, Z.C., Yu, Z., et al. (1997) Relationship between static, chemical and cyclic mechanical fatigue in feldspathic porcelain. Dental Materials, 13, 103-110. http://dx.doi.org/10.1016/S0109-5641(97)80019-X
|
[35]
|
Bragger, U., Aeschlimann, S., Burgin, W., et al. (2001) Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function. Clinical Oral Implants Research, 12, 26-34. http://dx.doi.org/10.1034/j.1600-0501.2001.012001026.x
|
[36]
|
Charles, R.J. (1958) Static fatigue of glass. II. Journal of Applied Physics, 29, 1554-1560. http://dx.doi.org/10.1063/1.1722992
|
[37]
|
Sherill, C.A. and O’brein, W.J. (1974) Transverse strength of aluminous and feldspathic porcelain. Journal of Dental Research, 53, 683-690. http://dx.doi.org/10.1177/00220345740530032801
|
[38]
|
Pjetursson, B.E., Brägger, U., Lang, N.P. and Zwahlen, M. (2007) Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs). Clinical Oral Implants Research, 18, 97-113. http://dx.doi.org/10.1111/j.1600-0501.2007.01439.x
|
[39]
|
Kreissl, M.E., Gerds, T., Muche, R., Heydecke, G. and Strub, J.R. (2007) Technical complications of implantsupported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clinical Oral Implants Research, 18, 720-726. http://dx.doi.org/10.1111/j.1600-0501.2007.01414.x
|
[40]
|
Kinsel, R.P. and Lin, D. (2009) Retrospective analysis of porcelain failures of metal ceramic crowns and fixed partial dentures supported by 729 implants in 152 patients: patient-specific and implant specific predictors of ceramic failure. Journal of Prosthetic Dentistry, 101, 388-394. http://dx.doi.org/10.1016/S0022-3913(09)60083-4
|
[41]
|
Misch, C.E. (2005) Dental implant prosthetics. Mosby, Inc., St. Louis, 457-475.
|
[42]
|
Keller, D., Hammerle, C.H.F. and Lang, N.P. (1996) Thresholds for tactile sensitivity perceived with dental implants remain unchanged during a healing phase of 3 months. Clinical Oral Implants Research, 7, 48-54. http://dx.doi.org/10.1034/j.1600-0501.1996.070106.x
|
[43]
|
Hammerle, C.H.F., Wagner, D., Bragger, U., Lussi, A., Karayiannis, A., Joss, A. and Lang, N.P. (1995) Threshold of tactile sensitivity perceived with dental endosseous implants and natural teeth. Clinical Oral Implants Research, 6, 83-90. http://dx.doi.org/10.1034/j.1600-0501.1995.060203.x
|
[44]
|
Schutle, W. (1995) Implants and the periodontium. International Dental Journal, 45, 16-26.
|
[45]
|
Jacobs, R. and van Steenberghe, D. (1994) Role of periodontal ligament receptors in the tactile function of teeth: A review. Journal of Periodontal Research, 29, 153-167. http://dx.doi.org/10.1111/j.1600-0765.1994.tb01208.x
|
[46]
|
Manly, R.S., Pfaffman, C., Lathorp, D.D. and Keyser, J. (1952) Oral sensory thresholds of persons with natural and artificial dentitions. Journal of Dental Research, 31, 305-312. http://dx.doi.org/10.1177/00220345520310030201
|
[47]
|
Hoffmann, O. and Zafiropoulos, G.G. (2012) The ToothImplant Connection: A Review. Journal of Oral Implantology, 38, 194-200. http://dx.doi.org/10.1563/AAID-JOI-D-10-00071
|
[48]
|
Chiche, G.J. and Pinault, A. (1991) Considerations for fabrication of implant-supported posterior restorations. The International Journal of Prosthodontics, 4, 37-44.
|
[49]
|
Shadid, R.M. and Sadaqa, N. (2012) A comparison between screw vs. cement retained implant prostheses: A literature review. Journal of Oral Implantology, 38, 298-307. http://dx.doi.org/10.1563/AAID-JOI-D-10-00146
|
[50]
|
Shadid, R.M., Abu-Naba’a, L., Al-Omari, W.M., Asfar, K.R. and EI Masoud, B.M. (2011) Effect of an occlusal screw-access hole on the fracture resistance of permanently cemented implant crowns: A laboratory study. The International Journal of Prosthodontics, 24, 267-269.
|
[51]
|
Al-Omari, W.M., Shadid, R., Abu-Naba'a, L. and El Masoud, B. (2010) Porcelain fracture resistance of screwretained, cement-retained, and screw-cement-retained implant-supported metal ceramic posterior crowns. Journal of Prosthodontics, 19, 263-273. http://dx.doi.org/10.1111/j.1532-849X.2009.00560.x
|
[52]
|
Karl, M., Graef, F., Taylor, T.D. and Heckmann, S.M. (2007) In vitro effect of load cyclingon metal-ceramic cement and screw-retained implant restorations. The Journal of Prosthetic Dentistry, 97, 137-140. http://dx.doi.org/10.1016/j.prosdent.2007.01.001
|
[53]
|
Torrado, E., Ercoli, C., Al Mardini, M., Graser, G.N., Tallents, R.H. and Cordaro, L. (2004) A comparison of the porcelain fracture resistance of screw-retained and cement-retained implant-supported metal-ceramic crowns. Journal of Prosthetic Dentistry, 91, 532-537. http://dx.doi.org/10.1016/j.prosdent.2004.03.014
|
[54]
|
Guichet, D.L., Caputo, A.A., Choi, H. and Sorensen, J.A. (2000) Passivity of fit and marginal opening in screw-or cement-retained implant fixed partial denture designs. The International Journal of Oral & Maxillofacial Implants, 15, 239-246.
|
[55]
|
Chee, W., Felton, D.A., Johnson, P.F. and Sullivan, D.Y. (1999) Cemented versus screw-retained implant prostheses: Which is better? The International Journal of Oral & Maxillofacial Implants, 14, 137-141.
|
[56]
|
Hebel, K.S. and Gajjar, R.C. (1997) Cement-retained versus screw-retained implant restoration: Achieving optimal occlusion and esthetics in implant dentistry. Journal of Prosthetic Dentistry, 77, 28-35. http://dx.doi.org/10.1016/S0022-3913(97)70203-8
|
[57]
|
Vigolo, P., Givani, A., Majzoub, Z. and Cordioli, G. (2004) Cemented versus screw-retained implant-supported single-tooth crowns: A 4-year prospective clinical study. The International Journal of Oral & Maxillofacial Implants, 19, 260-265.
|
[58]
|
Zarone, F., Sorrentino, R., Traini, T., Di lorio, D. and Caputi, S. (2007) Fracture resistance of implant-supported screwversus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis. Dental Materials, 23, 296-301. http://dx.doi.org/10.1016/j.dental.2005.10.013
|
[59]
|
Randow, K., Glantz, P.O. and Zoger, B. (1986) Technical failures and some related clinical complications in extensive fixed prosthodontics. An epidemiological study of long-term clinical quality. Acta Odontologica Scandinavica, 44, 241-255. http://dx.doi.org/10.3109/00016358608997726
|
[60]
|
Strub, J.R., Linter, H. and Marinello, C. (1989) Rehabilitation of partially edentulous patients using cantilever bridges, a retrospective study. The International Journal of Periodontics & Restorative Dentistry, 9, 364-375.
|
[61]
|
Rangert, B., Jemt, T. and Jorneus, L. (1989) Forces and moments on Brånemark implants. The International Journal of Oral & Maxillofacial Implants, 4, 241-247.
|
[62]
|
Pjetursson, B.E., Tan, K., Lang, N.P., Brägger, U., Egger, M. and Zwahlen, M. (2004) A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clinical Oral Implants Research, 15, 667-676. http://dx.doi.org/10.1111/j.1600-0501.2004.01120.x
|
[63]
|
Hälg, G.A., Schmid, J. and Hämmerle, C.H. (2008) Bone level changes at implants supporting crowns or fixed partial dentures with or without cantilevers. Clinical Oral Implants Research, 19, 983-990. http://dx.doi.org/10.1111/j.1600-0501.2008.01556.x
|
[64]
|
Zurdo, J., Romão, C. and Wennström, J.L. (2009) Survival and complication rates of implant-supported fixed partial dentures with cantilevers: A systematic review. Clinical Oral Implants Research, 20, 59-66. http://dx.doi.org/10.1111/j.1600-0501.2009.01773.x
|
[65]
|
Laurell, L., Lundgren, D., Falk, H. and Hugoson, A. (1991) Long term prognosis of extensive polyunit cantilevered fixed partial dentures. The Journal of Prosthetic Dentistry, 66, 545-552. http://dx.doi.org/10.1016/0022-3913(91)90521-W
|
[66]
|
Misch, C.E. (2005) Dental implant prosthetics. Mosby, Inc., St. Louis, 317.
|
[67]
|
Skalak, R. (1983) Biomechanical considerations in osseointegrated prostheses. The Journal of Prosthetic Dentistry, 49, 843-848. http://dx.doi.org/10.1016/0022-3913(83)90361-X
|
[68]
|
Bellini, C.M., Romeo, D., Galbusera, F., Taschieri, S., Raimondi, M.T., Zampelis, A. and Francett, L. (2009) Comparison of tilted versus nontilted implant-supported prosthetic designs for the restoration of the edentulous mandible: A biomechanical study. The International Journal of Oral & Maxillofacial Implants, 24, 511-517.
|
[69]
|
Naconecy, M.M., Geremia, T., Cervieri, A., Teixeira, E.R. and Shinka, R.S. (2010) Effect of the number of abutments on biomechanics of Brenamark prosthesis with straight and tilted distal implants. Journal of Applied oral Science, 18, 178-185. http://dx.doi.org/10.1590/S1678-77572010000200013
|
[70]
|
Bevilacqua, M., Tealdo, T., Menini, M., Pera, F., Mossolov, A., Drago, C. and Pera, P. (2011) The influence of cantilever length and implant inclination on stress distribution in maxillary implant-supported fixed dentures. Journal of Prosthetic Dentistry, 105, 5-13. http://dx.doi.org/10.1016/S0022-3913(10)60182-5
|
[71]
|
Straussberg, G., Katz, G. and Kuwata, M. (1966) Design of gold supporting structures for fused porcelain restorations. The Journal of Prosthetic Dentistry, 16, 928-936. http://dx.doi.org/10.1016/0022-3913(66)90015-1.
|