Share This Article:

The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter

Abstract Full-Text HTML Download Download as PDF (Size:738KB) PP. 733-739
DOI: 10.4236/epe.2013.54B142    3,617 Downloads   4,794 Views   Citations

ABSTRACT

Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load.

Cite this paper

X. Li, Z. Yan, K. Pan, C. Ma and H. Qi, "The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter," Energy and Power Engineering, Vol. 5 No. 4B, 2013, pp. 733-739. doi: 10.4236/epe.2013.54B142.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] F. Z. Peng, X. P. Fang, B. Gu, et al., “Z-Source Converter,” Transactions of China Electrotechnical Society, Vol. 19, No. 2, 2004, pp. 47-51.
[2] M. S. Shen, J. Wang, F. Z. Peng, et al., “Maximum Constant Boost Control of the Z-source Inverter,” IEEE Industry Applications Society Annual Meeting, 2004, pp. 142-147.
[3] E. Wit and J. McClure, “Statistics for Microarrays: Design, Analysis, and Inference,” 5th Edition, John Wiley & Sons Ltd., Chichester, 2004. doi:10.1002/0470011084
[4] X. P. Ding,Z. M. Qian,B. Cui,et al., “Fuzzy PID Controller for DC-link Boost Voltage in Z-source Inverter,” Proceedings of the CSEE, Vol. 28, No. 24, 2008, pp. 31-38.
[5] P. C. Loh, D. M. Vilathgamuwa, C. J. Gajanayake, Y. R. Lim and C. W. Teo, “Transient Modeling and Analysis of Pulse-Width Modulated Z-Source Inverter,” EEEE Transaction on Power Electronics, Vol. 22, No. 2, 2009, pp. 498-507.
[6] L. B. Li, Z. G. Zhao, et al., “Study on three-phase photovoltaic grid-connected inverter system based on compositive control,” Power System Protection and Control, 2010, Vol. 38, No. 21, pp. 44-47.
[7] L. Jun, T. C. Green and C. Feng, “Increasing Voltage Utilization inSplit-Link, Four-Wire Inverters,” IEEE Trans. on Power Electronics,” Vol. 6, No. 24, 2009, pp. 1562-1569.
[8] P. C. Loh, D. M. Vilathgamuwa, C. J. Gajanayake, L. T. Wong, C. P. Ang, “Z-Source Current—Type Inverters: Digital Modulation and Logic Implementation,” IEEE Transactions on Power Electronics, Vol. 22, No. 1, 2007, pp. 169-177. doi:10.1109/TPEL.2006.886618

  
comments powered by Disqus