American Journal of Analytical Chemistry

Volume 5, Issue 12 (September 2014)

ISSN Print: 2156-8251   ISSN Online: 2156-8278

Google-based Impact Factor: 1.49  Citations  

Quantitative Analysis of FeMo Alloys by X-Ray Fluorescence Spectrometry

HTML  Download Download as PDF (Size: 2678KB)  PP. 766-774  
DOI: 10.4236/ajac.2014.512085    5,383 Downloads   6,579 Views  Citations
Author(s)

ABSTRACT

A quantitative analysis method of molybdenum in FeMo alloys by X-ray spectrometry using borate fusion technique was compared with that with pressed pellet. The complete pre-oxidation of FeMo alloys for the preparation of homogeneous fused discs was achieved by employing an automated fusion machine equipped with specially designed O2-blowing nozzles, which used lithium tetra-borate as flux with the addition of lithium nitrate (LiNO3) as oxidizer. The calibration curves of Mo and Fe were used in the quantitative analysis of standard materials and unknown plant samples with satisfactory accuracy and precision, utilizing the corrections of the matrix effects and line overlap. It was confirmed that the newly proposed method of preparing fused glass discs of FeMo alloys can replace the conventional wet chemical analyses requiring the labor intensive and time consuming procedure.

Share and Cite:

Jung, S. (2014) Quantitative Analysis of FeMo Alloys by X-Ray Fluorescence Spectrometry. American Journal of Analytical Chemistry, 5, 766-774. doi: 10.4236/ajac.2014.512085.

Cited by

[1] Development and validation of energy dispersive x‐ray fluorescence method for quantification of cubic zirconia in diamond matrix
X‐Ray …, 2024
[2] Sulfonic acid polyimides and their salts: properties of their particles in solution and suspension
… and Technology: An …, 2023
[3] БЕРИЛЛИЕВЫЕ ФОЛЬГИ. НАУЧНО-ТЕХНОЛОГИЧЕСКИЕ ОСНОВЫ ИХ ПОЛУЧЕНИЯ
2021
[4] Multi-elemental ED-XRF Determination in Dehydrated Bouillon and Sauce Base Products
Food Analytical Methods, 2018
[5] INVESTIGATION OF THE POSSIBILITY OF IMPROVING THE X-RAY FLUORESCENCE SPECTROMETER ANALYTICAL CHARACTERISTICS DUE TO USING …
2018
[6] Investigation of the possibility of improving the x-ray fluorescence spectrometer analytical characteristics due to using the superfine beryllium foils
2018
[7] Improvement of XRF and PXRF analysis using elemental sensitivity method
2017
[8] Effect of the Addition of Molybdenum on the Structure and Corrosion Resistance of Zinc–Iron Plating
Coatings, 2017
[9] Development and Validation of an ED-XRF Method for the Fast Quantification of Mineral Elements in Dry Pet Food Samples
Food Analytical Methods, 2016
[10] Power Techniques for Improving Green Sand System Performance

Copyright © 2025 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.