World Journal of Cardiovascular Surgery

Volume 7, Issue 12 (December 2017)

ISSN Print: 2164-3202   ISSN Online: 2164-3210

Google-based Impact Factor: 0.10  Citations  

Malposition of Stent a Rare Complication in Coarctation of Aorta Corrected with Extraanatomic Aortic Bypass

HTML  XML Download Download as PDF (Size: 396KB)  PP. 164-168  
DOI: 10.4236/wjcs.2017.712019    1,216 Downloads   2,546 Views  

ABSTRACT

Mal-position of stent in coarctation of aorta is very rare but a major complication. Symptoms can worsen even more. We present here one such case where stenting done in some other institute in which we did an extra-anatomical bypass from ascending aorta to supracelial aorta successfully bypassing the coarct segment. This was an early approach without assistance of Cadio-pulmonary (CP) Bypass. We conclude that this procedure should be done in centres where experienced operator and cardiac surgery back up is present. This was a good approach without assistance of CP Bypass.

Share and Cite:

Kisku, N. , Pramanik, S. , Aditya, K. and Satyarthi, S. (2017) Malposition of Stent a Rare Complication in Coarctation of Aorta Corrected with Extraanatomic Aortic Bypass. World Journal of Cardiovascular Surgery, 7, 164-168. doi: 10.4236/wjcs.2017.712019.

Cited by

No relevant information.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License