Quality Control of Gamma Camera with SPECT Systems

HTML  XML Download Download as PDF (Size: 1083KB)  PP. 225-232  
DOI: 10.4236/ijmpcero.2017.63021    8,840 Downloads   21,056 Views  Citations

ABSTRACT

Quality control of Gamma Camera with SPECT System is highly valuable for assurance performance characteristic. We report the performance characteristic of gamma camera by intrinsic calibration and verification measurement. The study has been done using the data from Siemens Symbia S Series gamma camera by using a point source 99mTc at the Institute of Nuclear Medicine & Allied Sciences (INMAS), Khulna, Bangladesh. From intrinsic calibration and verification flood series, the integral uniformity for the central field of view (CFOV) has been found in between 4.01% and 2.88% and for the useful field of view (UFOV) has been in between 4.77% and 4.30%. The differential uniformity for the CFOV has been in between 1.53% and 2.04% and for the UFOV has been in between 2.32% and 2.77%. According to Operating Instruction Symbia System S Series manual, uniformity can compensate for values exceeding 10%, however while integral uniformity exceed 7%, have to contract Siemens customer service representative. In conclusion, these results show that the intrinsic uniformity of the gamma camera under this condition is within an acceptable range; thus the gamma camera working in INMAS is performed well.

Share and Cite:

Hasan, Md.R., Khan, Md.H.R., Rahman, Md.R., Parvez, Md.S., Islam, Md.R. and Paul, A.K. (2017) Quality Control of Gamma Camera with SPECT Systems. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 6, 225-232. doi: 10.4236/ijmpcero.2017.63021.

Cited by

[1] Polymeric Nanoparticles for Theranostic Treatment of Cancer
Functional Biomaterials: Drug …, 2022
[2] Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study
2021
[3] Review on Routine Quality Control Procedures in Nuclear Medicine Instrumentation
2020
[4] Evaluation of Quality control Program for SPECT cameras at all nuclear medicine Departments in Sudan
2019
[5] Comparison of SPECT quick QC between using in-house hot phantom and Jaszczak phantom: A preliminary study
Journal of Physics: Conference Series, 2019
[6] Development and Application of Gamma Camera in the Field of Nuclear Medicine
2018
[7] Estimation of patient radiation doses in nuclear medicine during bone scan
Thesis, 2018
[8] Evaluation the quality control program of SPECT cameras in nuclear medicine departments in Sudan
2018

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.