Optics and Photonics Journal

Volume 6, Issue 7 (July 2016)

ISSN Print: 2160-8881   ISSN Online: 2160-889X

Google-based Impact Factor: 0.76  Citations  h5-index & Ranking

Characterization of a Multimodal and Multispectral Led Imager: Application to Organic Polymer’s Microspheres with Diameter Φ = 10.2 μm

HTML  XML Download Download as PDF (Size: 4050KB)  PP. 171-183  
DOI: 10.4236/opj.2016.67019    1,904 Downloads   2,836 Views  Citations

ABSTRACT

Multispectral microscopy enables information enhancement in the study of specimens because of the large spectral band used in this technique. A low cost multimode multispectral microscope using a camera and a set of quasi-monochromatic Light Emitting Diodes (LEDs) ranging from ultraviolet to near-infrared wavelengths as illumination sources was constructed. But the use of a large spectral band provided by non-monochromatic sources induces variation of focal plan of the imager due to chromatic aberration which rises up the diffraction effects and blurs the images causing shadow around them. It results in discrepancies between standard spectra and extracted spectra with microscope. So we need to calibrate that instrument to be a standard one. We proceed with two types of images comparison to choose the reference wavelength for image acquisition where diffraction effect is more reduced. At each wavelength chosen as a reference, one image is well contrasted. First, we compare the thirteen well contrasted images to identify that presenting more reduced shadow. In second time, we determine the mean of the shadow size over the images from each set. The correction of the discrepancies required measurements on filters using a standard spectrometer and the microscope in transmission mode and reflection mode. To evaluate the capacity of our device to transmit information in frequency domain, its modulation transfer function is evaluated. Multivariate analysis is used to test its capacity to recognize properties of well-known sample. The wavelength 700 nm was chosen to be the reference for the image acquisition, because at this wavelength the images are well contrasted. The measurement made on the filters suggested correction coefficients in transmission mode and reflection mode. The experimental instrument recognized the microsphere’s properties and led to the extraction of the standard transmittance and reflectance spectra. Therefore, this microscope is used as a conventional instrument.

Share and Cite:

Agnero, M. , Zoueu, J. and Konan, K. (2016) Characterization of a Multimodal and Multispectral Led Imager: Application to Organic Polymer’s Microspheres with Diameter Φ = 10.2 μm. Optics and Photonics Journal, 6, 171-183. doi: 10.4236/opj.2016.67019.

Cited by

[1] Design of a Multimodal Light Sheet Optical System for Multivariate Applications in Phytopathology
2021
[2] Malaria-Infected Red Blood Cell Analysis through Optical and Biochemical Parameters Using the Transport of Intensity Equation and the Microscope's Optical …
2019
[3] Multi-height phase recovery combined with Fast Iterative Shrinkage-Thresholding Algorithm to handle phase microspheres from complex diffracted field in inline …
2019
[4] Nouvel outil de mesure non destructive de la qualité des mangues par télédétection
2019
[5] Malaria-infected red blood cell analysis through optical and biochemical parameters using the transport of intensity equation and the microscope's optical properties
2019
[6] A New Method to Retrieve the Three-Dimensional Refractive Index and Specimen Size Using the Transport Intensity Equation, Taking Diffraction into Account
Applied Sciences, 2018
[7] Multi-Spectral and Fluorescence Imaging in Prevention of Overdose of Herbicides: The Case of Maize
2017

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.