World Journal of Nuclear Science and Technology

Volume 6, Issue 1 (January 2016)

ISSN Print: 2161-6795   ISSN Online: 2161-6809

Google-based Impact Factor: 0.38  Citations  h5-index & Ranking

Limitations in the Use of the Equivalent Diameter

HTML  XML Download Download as PDF (Size: 585KB)  PP. 53-62  
DOI: 10.4236/wjnst.2016.61005    5,869 Downloads   8,919 Views  Citations

ABSTRACT

This paper deals with the inaccuracy assessment of the friction pressure loss estimation based on Darcy formula combined with an equivalent hydraulic diameter and a friction factor valid for circular pipes when applied to a square rod bundle. The assessment has been done by comparing the analytical and semi-empirical predictions with two different CFD codes results: CFX and NEPTUNE_CFD. Two different analytical approaches have been considered: the whole-bundle and sub-channel approaches, both for laminar and turbulent flow conditions. Looking at results, it is reasonable to assume that an error in the range of 11% - 23% is likely when using equivalent diameter in the laminar regime. In the case of turbulent regime, the equivalent diameter works better and the error is in the range between a few percent and ~12%.

Share and Cite:

Frate, L. , Moretti, F. , Galassi, G. and D’Auria, F. (2016) Limitations in the Use of the Equivalent Diameter. World Journal of Nuclear Science and Technology, 6, 53-62. doi: 10.4236/wjnst.2016.61005.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.