Open Journal of Radiology

Volume 5, Issue 3 (September 2015)

ISSN Print: 2164-3024   ISSN Online: 2164-3032

Google-based Impact Factor: 0.33  Citations  

Evaluation of Effective Dose Using the k-Factor of Optimal Scan Range for CT Examination

HTML  XML Download Download as PDF (Size: 686KB)  PP. 172-148  
DOI: 10.4236/ojrad.2015.53021    5,627 Downloads   7,733 Views  Citations

ABSTRACT

The American College of Radiology opened the computed tomography (CT) dose index registry (DIR) for general participation by all facilities in 2011. For each CT examination, data on volume CT dose index (CTDIvol), dose-length product (DLP), and, for body examinations, size-specific dose estimate (SSDE) were collected. However, effective dose is not estimated in DIR. The primary objective of this study was to estimate k-factor profile in detail at various scan positions with modified the ImPACT CT patient dosimetry. A tool that easily estimates the k-factor of suitable scan areas is essential for practical dose estimation in the DIR. We evaluated k-factor (effective dose/ DLP) profiles between a medical international radiation dose-five (MIRD-5) phantom positions using aImPACT software. As a result of this study, practicality of the k-factor profile method in clinical use was clarified. We speculate that a flexible k-factor improves the appropriateness of the E in hospital settings.

Share and Cite:

Kobayashi, M. , Asada, Y. , Matsubara, K. , Haba, T. , Matsunaga, Y. , Kawaguchi, A. , Katada, K. , Toyama, H. , Koshida, K. , Kato, R. and Suzuki, S. (2015) Evaluation of Effective Dose Using the k-Factor of Optimal Scan Range for CT Examination. Open Journal of Radiology, 5, 172-148. doi: 10.4236/ojrad.2015.53021.

Cited by

[1] 低線量肺がん CT 検診における異なる自動臓器線量推定ソフトウェアを用いた臓器線量と実効線量
日本放射線技術学会雑誌, 2022
[2] INTEGRATION OF AN INFORMATION SYSTEM TO SUGGEST A DRL MODEL IN RADIOLOGY DEPARTMENT AT AZADI HOSPITAL IN DUHOK–KURDISTAN …
2020
[3] 深層学習による CT 画像の自動分類と被ばく推定 Web システムを併用した実効線量推定作業の効率化
2020
[4] Evaluation of Radiation Dose in Coronary Computed Tomography-Angiography Examinations: Using Organ dose and Effective dose
2018
[5] Design And Fabrication Of A 3d Printed Thyroid Phantom For Radiation Dosimetry
2018
[6] Impact of acquisition protocol variations on effective dose and risk for CT head examinations
2018
[7] Dose Estimating Application Software Modification: Additional Function of a Size-Specific Effective Dose Calculator and Auto Exposure Control
2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.