Measurement of the Effective Dose Radiation at Radiology Departments of Some Hospitals in Duhok Governorate

HTML  XML Download Download as PDF (Size: 288KB)  PP. 566-572  
DOI: 10.4236/jmp.2015.65061    4,839 Downloads   6,827 Views  Citations

ABSTRACT

During operating of the X-ray machines, if the protection of X-ray rooms is insufficient, not only the patient but also clinical staffs as well as public are exposed to high X-ray dosage and they are affected from X-ray related to the dose level. In the present survey, by testing the radiological leakage and scatter from X-rays machines in radiology departments of 7 randomly selected hospitals in Duhok governorate, the effects dose of X-ray to the both control panel area and the patients waiting or visiting area who are located near the radiography room, were measured. The dose was recorded for a range of peak kilovoltage (kVp) and mAs values to find efficiency of shielding materials (barriers) of radiography rooms for different X-rays level. The measurements were performed at one meter above the ground surface which was the same height of X-rays tube by using Gamma Scout dosimeter. From the measurement results, it was seen that the most hospitals barriers (doors and walls) were not appropriate to the standards except 2 hospitals. The maximum effective doses were measured in uncontrolled area of Khazer hospital which was 82.48 ± 0.73 mSv·yr-1 that was much more than the reference dose limits and in controlled area of Haval Banda Zaroka hospital which was 12.98 ± 0.16 mSv·yr-1. In result, the knowledge about the radiation dose affecting the radiologists and public in the selected hospitals was obtained, and by informing the radiologists and the hospitals managements, the necessary regulations would be planned.

Share and Cite:

Bari, D. , Amin, P. and Abdulkareem, N. (2015) Measurement of the Effective Dose Radiation at Radiology Departments of Some Hospitals in Duhok Governorate. Journal of Modern Physics, 6, 566-572. doi: 10.4236/jmp.2015.65061.

Cited by

[1] Assessment of X-Ray Beam Collimation Practice and Light Beam Diaphragm Alignment in Gombe State, Nigeria
2020
[2] Assessment of Radiation Leakage from Diagnostic Rooms of Radiology Department of a Teaching Hospital in Kano, Northwestern Nigeria
2020
[3] Exposure Level to Caregivers Resulting From the Scattered Radiation During a Radiographic Procedure
2020
[4] Pattern of radiation safety measures and security culture in four major hospitals, Ismailia, Egypt
2020
[5] Scatter radiation dose assessment in the radiology department of Cape Coast Teaching Hospital-Ghana+ 5
Banahene, EO Darko, DF Charles, 2018
[6] A Study on Effective Dose to Patients and Workers During Diagnostic X-ray Procedure in UTHM Health Centre
2018
[7] Scatter Radiation Dose Assessment in the Radiology Department of Cape Coast Teaching Hospital-Ghana
2018
[8] Bazı Devlet Hastanelerindeki Tomografi, Röntgen ve Mamografi Cihazlarının Üç Farklı Noktada Radyasyon Sızıntı Ölçümleri
2016

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.