Open Journal of Orthopedics

Volume 4, Issue 10 (October 2014)

ISSN Print: 2164-3008   ISSN Online: 2164-3016

Google-based Impact Factor: 0.25  Citations  h5-index & Ranking

Biomechanical Stability of Open-Wedge High Tibial Osteotomy: Comparison of Two Locking Plates

HTML  XML Download Download as PDF (Size: 2760KB)  PP. 257-262  
DOI: 10.4236/ojo.2014.410042    3,709 Downloads   5,526 Views  Citations

ABSTRACT

Introduction: Recently, new plates with locking screws have been developed and used for medial open-wedge high tibial osteotomy (HTO). The purpose of this study was to evaluate and compare biomechanical properties of different internal fixations in open-wedge HTO using the two currently available locking plates. Methods: Eight paired fresh-frozen cadaveric lower extremities were vertically embedded in steel boxes. The axial compression load was applied to the legs using the mechanical testing machine. The axial compression load test from 0 N to 550 N and the failure test were performed before and after HTO. One side of the leg of a specimen was fixed with the Puddu locking plate and the other side was fixed with the TomoFix plate to compare the two plates using the same specimen. A mode of failure and vertical displacement of the medial and lateral parts of the tibia at the osteotomy gap was recorded using a video camera in the failure test. The load–displacement data were analyzed to calculate stiffness, failure load, and displacement at failure. Results: The mean failure load was 1471.4 N and 1692.3 N and total vertical displacement at failure was 3.1 mm and 2.9 mm with the Puddu and TomoFix plates, respectively. During axial compression loading, displacements mainly occurred at the lateral osteotomy gap, while the medial gap was well preserved. No significant differences were observed in the failure load, displacement, or mode of failure between the two plates. Conclusions: The Puddu and TomoFix plates had similar biomechanical properties in open-wedge HTO. The results indicated reliable stability after open-wedge HTO without fibular osteotomy.

Share and Cite:

Watanabe, K. , Kamiya, T. , Suzuki, D. , Otsubo, H. , Teramoto, A. , Suzuki, T. and Yamashita, T. (2014) Biomechanical Stability of Open-Wedge High Tibial Osteotomy: Comparison of Two Locking Plates. Open Journal of Orthopedics, 4, 257-262. doi: 10.4236/ojo.2014.410042.

Cited by

[1] Effects of plate contouring quality on the biomechanical performance of high tibial osteotomy fixation: A parametric finite element study
Proceedings of the Institution …, 2022
[2] Long-term survival and predictors of failure of opening wedge high tibial osteotomy.
2022
[3] Is a Complete Anatomical Fit of the Tomofix Plate Biomechanically Favorable? A Parametric Study Using the Finite Element Method
The Archives of Bone and …, 2022
[4] Biomechanical evaluation of high tibial osteotomy plate with internal support block using finite element analysis
2021
[5] Design optimization of high tibial osteotomy plates using finite element analysis for improved biomechanical effect
2019
[6] Graft materials provide greater static strength to medial opening wedge high tibial osteotomy than when no graft is included
2019
[7] The biomechanical effects of allograft wedges used for large corrections during medial opening wedge high tibial osteotomy
2019
[8] Mechanical strength of a new plate compared to six previously tested opening wedge high tibial osteotomy implants
2019
[9] Intramedullary nailing in opening wedge high tibial osteotomy—in vitro test for validation of a method of fixation
International Orthopaedics, 2018
[10] Numerical comparative study of five currently used implants for high tibial osteotomy: realistic loading including muscle forces versus simplified experimental …
2018
[11] Biomechanik neuer Implantate für die HTO.
Der Orthop?de, 2017
[12] Biomechanik neuer Implantate für die HTO
Der Orthop?de, 2017
[13] Static and fatigue strength of a novel anatomically contoured implant compared to five current open-wedge high tibial osteotomy plates
2017
[14] Biomechanik neuer Implantate für die HTO​ Biomechanics of new implants for HTO
Der Orthop?de, 2017
[15] Clinical and Cost-Effectiveness of a Locking Versus Non-Locking Fixation Plate in Medial Opening Wedge High Tibial Osteotomy
2016
[16] Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
Journal of Experimental Orthopaedics, 2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.