Health

Volume 1, Issue 1 (June 2009)

ISSN Print: 1949-4998   ISSN Online: 1949-5005

Google-based Impact Factor: 0.74  Citations  

Finite element analysis of a percutaneous aortic valve stent design

HTML  Download Download as PDF (Size: 2950KB)  PP. 2-7  
DOI: 10.4236/health.2009.11002    7,151 Downloads   12,681 Views  Citations

Affiliation(s)

.

ABSTRACT

Aim: This paper discusses the design and Finite Element Analysis (FEA) of a Percutaneous Aor-tic Valve Stent. The aim of this study was to model a percutaneous aortic valve stent and subject it to finite element analysis. The design process was carried out to meet the functional and surgical requirements. Methods and Results: Analysis was done with different materials with loads ranging from 50 kgf/mm² to 73 kgf/mm². These forces were selected because these val-ues are far greater than the normal human blood pressure which ranges from 10kPa to 16kPa. It was also to understand the mechanical behavior of different stent materials under such high pressures. A stent model was generated and its physical, mechanical and behavioral properties were studied. Finite element analysis and simulation of the model enhanced the designer to optimize the geometry suitable for perform-ance during and after implantation. The design objective for the stent is to have long term du-rability, low thrombogenicity, resistance to mi-gration and paravalvular leak. Conclusion: The analysis performed in this paper may aid in understanding the stent’s tolerable pressures ranges in comparison with the physiological pressures exerted by the heart and cardiac blood flow during abnormal cardiovascular conditions.

Share and Cite:

Kumar, G. and Mathew, L. (2009) Finite element analysis of a percutaneous aortic valve stent design. Health, 1, 2-7. doi: 10.4236/health.2009.11002.

Cited by

[1] அகநானூற்றில் தலைவனின் பரத்தமை ஒழுக்கம்-உளவியல் நோக்கும் தீர்வும்: Agananootril Thalaivanin …
… (Inam International E-Journal of Tamil Studies), 2022
[2] Stent biomaterial and design selection using finite element analysis for percutaneous aortic valve replacement
Artificial organs, 2011
[3] FLOW PATTERNS AND HEMODYNAMIC EFFICACY ANALYSIS IN A NOVEL PERCUTANEOUS STENTED AORTIC VALVE
Biomedical Engineering: Applications, Basis and Communications, 2011
[4] FATIGUE AND DURABILITY OF A NOVEL PERCUTANEOUS AORTIC VALVE STENT
Biomedical Engineering: Applications, Basis and Communications, 2011
[5] INNOVATIVE APPLICATION OF 3-D RAPID PROTOTYPING TECHNOLOGY FOR TEACHING PROJECT DESIGN
ICERI2010 Proceedings, 2010

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.