Journal of Power and Energy Engineering

Volume 2, Issue 4 (April 2014)

ISSN Print: 2327-588X   ISSN Online: 2327-5901

Google-based Impact Factor: 1.46  Citations  

Automatic System for Failure Detection in Hydro-Power Generators

HTML  Download Download as PDF (Size: 1118KB)  PP. 36-46  
DOI: 10.4236/jpee.2014.24006    6,660 Downloads   7,797 Views  Citations

ABSTRACT

This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interference in the generator operation. The detected failures could be mechanical or electrical origins, such as: problems in bearings, unwanted vibrations, partial discharges, misalignment, unbalancing, among others. It is possible because the generator acts as a transducer for mechanical problems, and they appear in current and voltage signals. This automatic system based on electric signature analysis has been installed in Itapebi Power Plant generators since 2012. Some results are presented in this paper.

Share and Cite:

Ribeiro, L. , Oliveira, L. , Bonaldi, E. , Silva, L. , Salomon, C. , Silva, J. and Lambert-Torres, G. (2014) Automatic System for Failure Detection in Hydro-Power Generators. Journal of Power and Energy Engineering, 2, 36-46. doi: 10.4236/jpee.2014.24006.

Cited by

[1] A New Multi-Objective Design for Optimal Placement of Gas Turbines considering Black-start Capability Improvement
Computational Intelligence in Electrical Engineering, 2019
[2] Multi-Objective Model for Allocation of Gas Turbines with the Aim of Black-Start Capability Enhancement in Smart Grids
2019
[3] Flooding Power Utilization In A Equatorial Canyon Rice
2019
[4] یک طراحی چند هدفه جدید برای جایابی بهینه واحدهای توربین گازی به منظور بهبود قابلیت خودراه اندازی‎
2019
[5] A new optimal contingency‐based design for placement of gas turbines to enhance black‐start capability
International Transactions on Electrical Energy Systems, 2018
[6] Simulation of a 3-φ, 4-Level Inverter with a Discrete 3-φ PWM Generator for the Suppression of the Harmonics
2016
[7] Modeling, evaluation, and optimization of gas-power and energy supply scenarios
Frontiers in Energy, 2016
[8] Monitoramento Inteligente para Manutenção Preditiva de Turbogeradores
2016
[9] APLICAÇÃO DE FFT PARA A DETECÇÃO DE DEFEITOS EM MÁQUINAS ELÉTRICAS
Blucher Mathematical Proceedings, 2015
[10] Development of a reduced-model laboratory for testing predictive fault system in internal combustion engines
Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED), 2015 IEEE 10th International Symposium on, 2015
[11] Predictive Maintenance System for Thermal Generator Units
International Journal of Advanced Research inComputer Science & Technology, 2014

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.