Comparison of the Motion Accuracy of a Six Degrees of Freedom Radiotherapy Couch with and without Weights

HTML  Download Download as PDF (Size: 608KB)  PP. 69-75  
DOI: 10.4236/ijmpcero.2013.23010    5,147 Downloads   9,224 Views  Citations

ABSTRACT

In this study, we compared the motion accuracy of six degrees of freedom (6D) couch for precision radiotherapy with or without weights attached to the couch. Two digital cameras were focused on the iso-center of a linear accelerator. Images of a needle which had been fixed to the 6D couch were obtained using the cameras when the couch moved in translation and rotation around each axis. The three-dimensional (3D) coordinates of the needle were calculated from coordinate values in the images. A coordinate error of the needle position relative to the theoretical position was calculated. The errors were obtained with or without a 60 kg weight attached to the 6D couch, and these errors were compared with each other. The mean distance of the 3D error vectors for the weighted test was 0.21 ± 0.11 mm, and >0.16 ± 0.09 mm for the non-weighted test (p < 0.05). However, the difference of two values was 0.06 mm which is smaller than the minimum distance the 6D couch system can correctly move. The variance of 0.16 mm for the Y coordinate errors for the weighted test only was larger than that for the non-weighted test, which was 0.06 mm (p < 0.05). We found that a total weight of 60 kg did not affect the accuracy of the 6D couch clinically. However, the variance of the Y coordinate errors was increased. This might suggest that the addition of this weight increased the uncertainty of the motion of the 6D couch.

Share and Cite:

A. Takemura, S. Ueda, K. Noto, H. Kojima and N. Isomura, "Comparison of the Motion Accuracy of a Six Degrees of Freedom Radiotherapy Couch with and without Weights," International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, Vol. 2 No. 3, 2013, pp. 69-75. doi: 10.4236/ijmpcero.2013.23010.

Cited by

[1] Performance of a linear accelerator couch positioning quality control task using an electronic portal imaging device
2020
[2] Performance of a linear accelerator couch positioning quality control task using an electronic portal imaging device.
2020
[3] Quality assurance for a six degrees‐of‐freedom table using a 3D printed phantom
Journal of applied clinical medical physics, 2018
[4] Verify Image-Guided Shifts for 6DoF Couch using Yonsei Cancer Center QA Set
2017
[5] Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target
2017
[6] Yonsei Cancer Center QA Set 을 이용한 6DoF Couch 의 이동 정확성 검증
2017
[7] Αδρονική θεραπεία: βασικές αρχές, συγκριτική μελέτη αδρονικής θεραπείας έναντι ακτινοθεραπείας, πλεονεκτήματα-μειονεκτήματα
2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.