Open Journal of Obstetrics and Gynecology

Volume 3, Issue 3 (May 2013)

ISSN Print: 2160-8792   ISSN Online: 2160-8806

Google-based Impact Factor: 0.37  Citations  h5-index & Ranking

Critical evaluation of American categorization of fetal heart rate (FHR) decelerations and three tier classification—Shortcomings, contradictions, remedies and need for debate

HTML  XML Download Download as PDF (Size: 661KB)  PP. 362-370  
DOI: 10.4236/ojog.2013.33067    5,994 Downloads   10,990 Views  Citations

ABSTRACT

Fetal heart rate (FHR) decelerations are the commonest aberrant feature on cardiotocograph (CTG) thus having a major influence on classification ofFHRpatterns into the three tier system. The unexplained paradox of early decelerations (head compressionan invariable phenomenon in labor) being extremely rare [1] should prompt a debate about scientific validity of current categorization. This paper demonstrates that there appear to be major fallacies in the pathophysiological hypothesis (cord compressionbaroreceptor mechanism) underpinning of vast majority of (variable?) decelerations. Rapid decelerations during contractions with nadir matching peak of contractions are consistent with “pure” vagal reflex (head compression) rather than result of fetal blood pressure or oxygenation changes from cord compression. Hence, many American authors have reported that the abrupt FHR decelerations attributed to cord compression are actually due to head compression [2-6]. The paper debates if there are major fundamental fallacies in current categorization of FHR decelerations based concomitantly on rate of descent (reflecting putative aetiology?) and time relationship to contractions. Decelerations with consistently early timing (constituting majority) seem to get classed as “variable” because of rapid descent. A distorted unscientific categorization of FHR decelerations could lead to clinically unhelpful three tier classification system. Hence, the current unphysiological classification needs a fresh debate with consideration of alternative models and re-evaluation of clinical studies to test these. Open debate improves patient care and safety. The clue to benign reflex versus hypoxic nature of decelerations seems to be in the timing rather than the rate of descent. Although the likelihood of fetal hypxemia is related to depth and duration ofFHRdecelerations, the cut-offs are likely to be different for early/late/variable decelerations and it seems to be of paramount importance to get this discrimination right for useful visual or computerized system of CTG interpretation.


Share and Cite:

Sholapurkar, S. (2013) Critical evaluation of American categorization of fetal heart rate (FHR) decelerations and three tier classification—Shortcomings, contradictions, remedies and need for debate. Open Journal of Obstetrics and Gynecology, 3, 362-370. doi: 10.4236/ojog.2013.33067.

Cited by

[1] Myths at the core of Intrapartum Cardiotocography Interpretation–Risks of false Ideology, Prospect theory and way forward
2019
[2] Annals of Obstetrics and Gynecology
2019
[3] Myths at the core of intrapartum cardiotocography interpretation-Risks of false ideology, Prospect theory and way forward
Clin Obstet Gynecol Reprod Med, 2019
[4] Obstetrics at Decisive Crossroads Regarding Pattern-Recognition of Fetal Heart Rate Decelerations: Scientific Principles and Lessons From Memetics
Journal of clinical medicine research, 2018
[5] Letter to the Lancet INFANT trial-wider lessons and need for the reform of cardiotocography interpretation
2017
[6] Obstetrics at Momentous Crossroads Regarding Interpretation of Fetal Heart Rate Decelerations with three fateful directions-Scientific Principles and Lessons …
2017
[7] Limits of Current Cardiotocography Interpretation May Call for A Major Rethink
American Journal of Obstetrics and Gynecology, 2017
[8] Critical Imperative for the Reform of British Interpretation of Fetal Heart Rate Decelerations: Analysis of FIGO and NICE Guidelines, Post-Truth Foundations, …
Journal of clinical medicine research, 2017
[9] Is the hypothesis that the commonest fetal heart rate decelerations are caused by peripheral chemoreflex due to fetal hypoxaemia correct?
The Journal of physiology, 2017
[10] Deceleration area and fetal acidemia
Plant Biosystems - An International Journal Dealing with all Aspects of Plant Biology, 2016
[11] Clinical applicability of immunotherapy of cervical intraepithelial neoplasia
World J Obstet Gynecol., 2016
[12] Imperative for improvements and international convergence of intrapartum fetal monitoring: A bird's eye view
World J Obstet Gynecol, 2016
[13] Categorization of Fetal Heart Rate Decelerations in American and European Practice: Importance and Imperative of Avoiding Framing and Confirmation Biases
Journal of clinical medicine research, 2015
[14] Intermittent Auscultation in Labor: Could It Be Missing Many Pathological (Late) Fetal Heart Rate Decelerations? Analytical Review and Rationale for Improvement Supported by Clinical Cases
Journal of clinical medicine research, 2015
[15] Imperative for improvements and international convergence of intrapartum fetal monitoring: A bird’s eye view
World Journal of Obstetrics and Gynecology, 2015
[16] Repositorio Institucional de Documentos
2015
[17] Imperative for improvements and international convergence of intrapartumfetal monitoring: A bird’s eye view
World Journal of Obstetrics and Gynecology, 2015
[18] Área de la desaceleración y acidemia neonatal
2015
[19] In Reply
Obstetrics & Gynecology, 2014
[20] La classification du rythme cardiaque foetal par catégories permet-elle de prédire le statut acido-basique artériel ombilical néonatal?
2014
[21] Algorithm for management of category II fetal heart rate tracings: a standardization of right sort?
American journal of obstetrics and gynecology, 2014
[22] The unresolved role of cardiotocography (CTG), fetal ECG (STAN) and intrapartum fetal pulse oximetry (IFPO) as diagnostic methods for fetal hypoxia
Journal of Obstetrics & Gynaecology, 2014
[23] Are 'early'and 'late'fetal heart rate decelerations extinct? A survey of British midwives and analysis of controversies, facts and fiction
British Journal of Midwifery, 2013
[24] Interpretation of British experts’ illustrations of fetal heart rate (FHR) decelerations by Consultant Obstetricians, registrars and midwives: A prospective study—Reasons for major disagreement with experts and implications for clinical practice
Open Journal of Obstetrics and Gynecology, 2013
[25] Interpretation of British experts' illustrations of fetal heart rate (FHR) decelerations by Consultant Obstetricians, registrars and midwives: A prospective study …
2013

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.