American Journal of Analytical Chemistry

Volume 3, Issue 11 (November 2012)

ISSN Print: 2156-8251   ISSN Online: 2156-8278

Google-based Impact Factor: 1.71  Citations  h5-index & Ranking

Flow-Injection Flame Atomic Absorption Determination of Hexavalent Chromium with On-Line Preconcentration on an Anion Imprinted Polymer

HTML  Download Download as PDF (Size: 319KB)  PP. 755-760  
DOI: 10.4236/ajac.2012.311100    3,949 Downloads   6,391 Views  Citations

ABSTRACT

A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridineco-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexava-lent chromium was eluted with a small volume of diluted hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. An enrichment factor of 550 and a 3σ detection limit of 0.04 μg·L-1 along a sampling frequency of 4 h-1 at a sample flow rate of 3.5 mL·min-1. The relative standard deviation is 2.9% for 1 μg·L-1 Cr(VI) (n = 11). The flow injection system proposed has the advantage of being simpler because the use of expensive and sophisticated instruments is avoided. Ease of use, continuous process and selectivity make this method suitable for Cr(VI) determination in different environmental samples such as sea and river waters, soils and sediments.

Share and Cite:

M. Yebra-Biurrun, J. Castro-Romero and N. Carro-Mariño, "Flow-Injection Flame Atomic Absorption Determination of Hexavalent Chromium with On-Line Preconcentration on an Anion Imprinted Polymer," American Journal of Analytical Chemistry, Vol. 3 No. 11, 2012, pp. 755-760. doi: 10.4236/ajac.2012.311100.

Cited by

[1] Immobilized reagent disodium salt of 1, 8-dioxynaphthalene-3, 6-disulfonic acids for the determination of chromium ions
AIP Conference …, 2022
[2] Recent Advances in On-line Methods Based on Extraction for Speciation Analysis of Chromium in Environmental Matrices
Critical Reviews in Analytical Chemistry, 2015
[3] FLOW-INJECTION ANALYSIS: PRINCIPLES AND APPLICATIONS
2015
[4] Poly o-Toluidine Zirconium (IV) Iodosulfosalicylate-Based Ion-Selective Membrane Electrode for Potentiometric Determination of Cr (III) Ions and Its Analytical Applications
Industrial & Engineering Chemistry Research, 2014
[5] Poly o-Toluidine Zirconium(IV) Iodosulfosalicylate-Based Ion-Selective Membrane Electrode for Potentiometric Determination of Cr(III) Ions and Its Analytical …
Industrial & Engineering Chemistry, 2014

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.