ABSTRACT

There is considerable interest in quantitatively measuring nucleic acids from single cells to small populations. The most commonly employed laboratory method is the real-time polymerase chain reaction (PCR) analyzed with the crossing point or crossing threshold (Ct) method. Utilizing a multiwell plate reader we have performed hundreds of replicate reactions each at a set of initial conditions whose initial number of copies span a concentration range of ten orders of magnitude. The resultant Ct value distributions are analyzed with standard and novel statistical techniques to assess the variability/reliability of the PCR process. Our analysis supports the following conclusions. Given sufficient replicates, the mean and/or median Ct values are statistically distinguishable and can be rank ordered across ten orders of magnitude in initial template concentration. As expected, the variances in the Ct distributions grow as the number of initial copies declines to 1. We demonstrate that these variances are large enough to confound quantitative classi?cation of the initial condition at low template concentrations. The data indicate that a misclassi?cation transition is centered around 3000 initial copies of template DNA and that the transition region correlates with independent data on the thermal wear of the TAQ polymerase enzyme. We provide data that indicate that an alternative endpoint detection strategy based on the theory of well mixing and plate ?lling statistics is accurate below the mis- classi?cation transition where the real time method becomes unreliable.

Share and Cite:

Stowers, C. , Haselton, F. and Boczko, E. (2010) An analysis of quantitative PCR reliability through replicates using the Ct method. Journal of Biomedical Science and Engineering, 3, 459-469. doi: 10.4236/jbise.2010.35064.

Cited by

[1] Detection of herpes simplex virus 2: a SYBR-Green-based real-time PCR assay
F1000Research, 2021
[2] with reservations
2021
[3] Delivery of Messenger RNA to platelets using lipid nanoparticles
2019
[4] The role of ambient temperature in the generative transition of cauliflower
2018
[5] Фиксированные лимфоциты человека как источник ДНК для ПЦР-диагностики
2016
[6] A pilot study of the noninvasive assessment of the lung microbiota as a potential tool for the early diagnosis of ventilator-associated pneumonia
CHEST Journal, 2015
[7] Optimal treatment of replicate measurements in anthropometric studies
Annals of human biology, 2014
[8] Identification of nuclear-enriched miRNAs during mouse granulopoiesis
Journal of hematology & oncology, 2014
[9] Detecting respiratory syncytial virus using nanoparticle-amplified immuno-PCR
NanoBiotechnology Protocols, 2013
[10] Targeted, high-depth, next-generation sequencing of cancer genes in formalin-fixed, paraffin-embedded and fine-needle aspiration tumor specimens
The Journal of Molecular Diagnostics, 2013
[11] Deconvolution of the confounding variations for reverse transcription quantitative real-time polymerase chain reaction by separate analysis of biological replicate data
Analytical biochemistry, 2012
[12] Non-invasive detection of pulmonary pathogens in ventilator-circuit filters by PCR
American journal of translational research, 2012
[13] Detection of respiratory syncytial virus using nanoparticle amplified immuno-polymerase chain reaction
Analytical biochemistry, 2011

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.