Precision of a Parabolic Optimum Calculated from Noisy Biological Data, and Implications for Quantitative Optimization of Biventricular Pacemakers (Cardiac Resynchronization Therapy)

HTML  Download Download as PDF (Size: 243KB)  PP. 1497-1506  
DOI: 10.4236/am.2011.212212    5,715 Downloads   9,038 Views  Citations
Author(s)

Affiliation(s)

.

ABSTRACT

In patients with heart failure and disordered intracardiac conduction of activation, doctors implant a biven- tricular pacemaker (“cardiac resynchronization therapy”, CRT) to allow adjustment of the relative timings of activation of parts of the heart. The process of selecting the pacemaker timings that maximize cardiac function is called “optimization”. Although optimization—more than any other clinical assessment—needs to be precise, it is not yet conventional to report the standard error of the optimum alongside its value in clinical practice, nor even in research, because no method is available to calculate precision from one optimization dataset. Moreover, as long as the determinants of precision remain unknown, they will remain unconsidered, preventing candidate haemodynamic variables from being screened for suitability for use in optimization. This manuscript derives algebraically a clinically-applicable method to calculate the precision of the optimum value of x arising from fitting noisy biological measurements of y (such as blood flow or pressure) obtained at a series of known values of x (such as atrioventricular or interventricular delay) to a quadratic curve. A formula for uncertainty in the optimum value of x is obtained, in terms of the amount of scatter (irreproducibility) of y, the intensity of its curvature with respect to x, the width of the range and number of values of x tested, the number of replicate measurements made at each value of x, and the position of the optimum within the tested range. The ratio of scatter to curvature is found to be the overwhelming practical determinant of precision of the optimum. The new formulae have three uses. First, they are a basic science for anyone desiring time-efficient, reliable optimization protocols. Second, asking for the precision of every reported optimum may expose optimization methods whose precision is unacceptable. Third, evaluating precision quantitatively will help clinicians decide whether an apparent change in optimum between successive visits is real and not just noise.

Share and Cite:

D. Francis, "Precision of a Parabolic Optimum Calculated from Noisy Biological Data, and Implications for Quantitative Optimization of Biventricular Pacemakers (Cardiac Resynchronization Therapy)," Applied Mathematics, Vol. 2 No. 12, 2011, pp. 1497-1506. doi: 10.4236/am.2011.212212.

Cited by

[1] Optimizing atrio‐ventricular delay in pacemakers using potentially implantable physiological biomarkers
Pacing and Clinical …, 2022
[2] Improving haemodynamic optimization of cardiac resynchronization therapy for heart failure
2019
[3] Multicenter randomized controlled crossover trial comparing hemodynamic optimization against echocardiographic optimization of AV and VV delay of cardiac …
2018
[4] Atrioventricular optimized direct His bundle pacing improves acute hemodynamic function in patients with heart failure and PR interval prolongation without …
JACC: Clinical Electrophysiology, 2015
[5] Atrioventricular optimized direct His bundle pacing improves acute hemodynamic function in patients with heart failure and PR interval prolongation without left bundle …
2015
[6] Evidence that conflict regarding size of haemodynamic response to interventricular delay optimization of cardiac resynchronization therapy may arise from differences …
EP Europace, 2015
[7] “Cardiac resynchronisation therapy”: Does the haemodynamic improvement of biventricular pacing truly arise from cardiac resynchronisation?
2015
[8] Evidence that conflict regarding size of haemodynamic response to interventricular delay optimization of cardiac resynchronization therapy may arise from differences in how atrioventricular delay is kept constant
Europace, 2015
[9] A novel curve fitting method for AV optimisation of biventricular pacemakers
Physiological Measurement, 2015
[10] Atrioventricular Optimized Direct His Bundle Pacing Improves Acute Hemodynamic Function in Patients With Heart Failure and PR Interval Prolongation Without Left Bundle Branch Block
JACC: Clinical Electrophysiology, 2015
[11] Evidence that conflict regarding size of haemodynamic response to interventricular delay optimization of cardiac resynchronization therapy may arise from differences …
2015
[12] British randomised controlled trial of AV and VV optimization (“BRAVO”) study: rationale, design, and endpoints
BMC cardiovascular disorders, 2014
[13] Cardiac resynchronization therapy and AV optimization increase myocardial oxygen consumption, but increase cardiac function more than proportionally
International journal of cardiology, 2014
[14] Strategies to improve cardiac resynchronization therapy
Nature Reviews Cardiology, 2014
[15] British randomised controlled trial of AV and VV optimization
BMC cardiovascular disorders, 2014
[16] How to reliably deliver narrow individual-patient error bars for optimization of pacemaker AV or VV delay using a “pick-the-highest” strategy with haemodynamic measurements
International journal of cardiology, 2013
[17] Comparison of different invasive hemodynamic methods for AV delay optimization in patients with cardiac resynchronization therapy: implications for clinical trial design and clinical practice
International journal of cardiology, 2013
[18] A systematic approach to designing reliable VV optimization methodology: Assessment of internal validity of echocardiographic, electrocardiographic and haemodynamic optimization of cardiac resynchronization therapy
International journal of cardiology, 2013
[19] Cardiac resynchronisation therapy optimisation strategies: systematic classification, detailed analysis, minimum standards and a roadmap for development and testing
International journal of cardiology, 2013
[20] Cardiac resynchronization therapy and AV optimization increase myocardial oxygen consumption, but increase cardiac function more than proportionally☆
2013
[21] Comparison of different invasive hemodynamic methods for AV delay optimization in patients with cardiac resynchronization therapy: implications for clinical …
International Journal of Cardiology, 2013
[22] How to reliably deliver narrow individual-patient error bars for optimization of pacemaker AV or VV delay using a “pick-the-highest” strategy with haemodynamic …
International Journal of Cardiology, 2013
[23] A systematic approach to designing reliable VV optimization methodology: assessment of internal validity of echocardiographic, electrocardiographic and …
International Journal of Cardiology, 2013
[24] Cardiac Resynchronization Therapy Mechanisms in Atrial Fibrillation
Heart failure clinics, 2013
[25] Improvement in coronary blood flow velocity with acute biventricular pacing is predominantly due to an increase in a diastolic backward-travelling …
2012
[26] Improvement in coronary blood flow velocity with acute biventricular pacing is predominantly due to an increase in a diastolic backward-travelling decompression …
2012
[27] Atrioventricular and interventricular delay optimization and response quantification in biventricular pacing: arrival of reliable clinical algorithms and research protocols …
EP Europace, 2012
[28] Atrioventricular and interventricular delay optimization and response quantification in biventricular pacing: arrival of reliable clinical algorithms and research protocols, …
2012
[29] Atrioventricular and interventricular delay optimization and response quantification in biventricular pacing: arrival of reliable clinical algorithms and research protocols, and how to distinguish them from unreliable counterparts
Europace, 2012
[30] Improvement in coronary blood flow velocity with acute biventricular pacing is predominantly due to an increase in a diastolic backward-travelling decompression (suction) wave
Circulation, 2012
[31] Fully automatable, reproducible, noninvasive simple plethysmographic optimization: proof of concept and potential for implantability
Pacing and Clinical Electrophysiology, 2012

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.