Natural Convection through Air Filter Media for Cooling of Remote Radio Heads

HTML  Download Download as PDF (Size: 1497KB)  PP. 49-58  
DOI: 10.4236/jectc.2014.42006    4,100 Downloads   5,765 Views  

ABSTRACT

Passive cooling techniques are cost effective and reliable methods of cooling remote radio heads (RRH). This paper investigates the plausibility of a passive cooling technique involving exchanging warm air, from the internal cavity of RRHs, with fresh ambient air, to reduce the operating temperature using natural convection across air filters. The results indicate that, an internal air filter tube structure, with width of the enclosure, running vertically up the middle of an RRH, along with 4 pleat filter sides (2.0 ± 0.5 cm separation) provides the most effective outdoor suitable setup out of those examined. This provides a reduction in temperature of 3.9°K ± 0.4°K in the PA and 4.0°K ± 0.4°K in the radio, and a reduction in mass of 0.45 ± 0.05 kg, and is capable of withstanding water ingress and corrosive conditions including wind driven rain and salt fog.

Share and Cite:

Martin, A. and Akalanne, L. (2014) Natural Convection through Air Filter Media for Cooling of Remote Radio Heads. Journal of Electronics Cooling and Thermal Control, 4, 49-58. doi: 10.4236/jectc.2014.42006.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License