Thermal Conductivity Enhancement of Epoxy by Hybrid Particulate Fillers of Graphite and Silicon Carbide ()
1. Introduction
Polymers in general have low thermal conductivity due to low atomic density, chemical bonding, complex crystal structure [1] and anharmonicity in molecular vibrations [2] . The heat transfer in non metals occurs by phonon or lattice vibrations causing thermal resistance [3] . Epoxy as a matrix has a wide applications in the field of engineering. They have some of the favorable properties such as compatibility with many materials, higher thermal and chemical resistance cheaper than other thermosets. However, due to its cross linked structure, epoxies have disadvantages like brittleness, low impact strength, low wear resistance [4] . Epoxies are poor conductors of heat and current. Hence to improve their thermal conductivity, one of the routes is to reinforce particulate fillers. Excellent conductive properties of epoxies have applications in miniature devices managing heat transfer. To improve thermal conductivity, the thermal resistance has to be minimized. A good interfacial adhesion by modifying the filler surface reduces thermal resistance [5] . Further, when the thermal conductivity of the filler is more than 100 times the thermal conductivity of the polymer matrix, there will not be substantial increase in thermal conductivity of the composite [3] . To overcome this, the aspect ratio of the filler has to be increased so as to create conductive paths [6] [7] . The conductive paths can be created by increasing the volume fraction of fillers, increasing the size of particles and use of hybrid fillers. The fillers with large aspect ratio are capable of creating a conductive network [8] [9] . Hence, the present study looks into the modification of epoxy, by incorporation of particulates of Gr, SiC and hybrid (Gr-SiC) at various weight fractions to improve thermal conductivity. The Gr is considered as one of the best conductive filler due to its ability to disperse in a matrix, low cost and good thermal conductivity [1] . SiC microfiller is a choice material for high temperature and high power applications, as it has high thermal conductivity and low thermal expansion coefficient [10] .
2. Experimental Details
2.1. Materials Selecting a Template
Micro particulates of Graphite (Gr) supplied by SD fine chem ltd, India having size less than 60 µm and particulates of Silicon carbide (SiC) supplied by Gran Silica India, having size less than 20 µm (Figure 1) were used as fillers. The host matrix is an epoxy resin of type LY556 (RT cure) and an amine hardener HY951 supplied by Huntsman India Ltd. The resin and hardener were mixed in the weight ratio 10:1.
2.2. Specimen Preparation and Characterization
A metallic mould was fabricated to give specimens of 2 mm thick and 25 mm diameter which is coin shaped as shown in Figure 2. Before casting, the mould was cleaned thoroughly and a gel coat was applied to the mould. The particulates were preheated to remove any moisture present in it. The predetermined amounts of fillers were dispersed in epoxy resin, stirring continuously till the time of pouring. The cast specimens were allowed to cure in the mould for 24 hours at room temperature. The room temperature cured specimens were post cured for the following schedule of 50˚C for 30 minutes, 70˚C for 60 minutes and 85˚C for 120 minutes. To begin with, unfilled epoxy was cast first. Further, Gr-epoxy, SiC-epoxy and hybrid (Gr-SiC) epoxy composites were cast. The weight fractions of particulates of Gr and SiC were varied from 10% to 40% (maximum) in steps of 10%. In the next step, hybrid (Gr-SiC) filled epoxy composites were cast containing the filler weight fraction as given below.
(a) (b)
Figure 1. SEM Photographs of particulates of Gr and SiC. (a) SiC particles; (b) Gr particles.
(a) (b)
Figure 2. Cast specimens of epoxy and (Gr-SiC) epoxy hybrid composite. (a) Unfilled epoxy; (b) (Gr-SiC) Hybrid epoxy composite.
Gr fraction kept at 5%, SiC fraction varied from 5% to 35% in steps of 10%.
Gr fraction kept at 10%, SiC fraction varied from 10% to 30% in steps of 10%.
SiC fraction kept at 5%, Gr fraction varied from 5% to 35% in steps of 10%.
SiC fraction kept at 10%, Gr fraction varied from 10% to 30% in steps of 10%.
Both SiC and Gr fraction varied equally up to 40% in steps of 10%.
The different types of cast composites along with their codes are presented in Table 1. For ex composite 5S35G-Ep represents particulate content of 5% SiC, 35% Gr and 60% epoxy. Similarly a composite having code 10G30S-Ep has 10% Gr, 30% SiC and 60% epoxy.
2.3. Measurement of Thermal Conductivity
Thermal conductivity measurements were carried out by an instrument developed by Indian national academy of science. The schematic diagram of the set up is shown in Figure 3. The thermal conductivity measurements were based on steady state method. One directional heat flow was considered for measurement of thermal conductivity.
2.4. Description of the Apparatus
A heater made of six 120-Ohm 1/4 W resistors in parallel is placed in the copper cup of 25 mm diameter. It is connected to a constant current source. Two cast specimens are clamped between the copper cup and two square copper plates. Two junctions of a copper constantan thermocouple are fixed to upper half of the copper heater cup and to the upper square plate. Another pair of junctions of the thermocouple is fixed to bottom edge of the bottom half of the heater cup and bottom square plate. The leads from the thermocouple are connected to the differential amplifier. The specimens are fixed in between the square plate and the copper cup. The set up is connected to a constant current source. The outputs from the thermocouples are connected to a DC differential amplifier. Initially the current is set at 140 mA. The steady state is obtained after 45 mins. The output voltage is measured on a digital multimeter for thermocouple 1 and the process is repeated for thermocouple 2. Further the current is increased to 160 mA and the measurements are repeated. The measurements are repeated for five different current settings and two specimens were used for each experiment.
The experimental thermal conductivity is evaluated using the equation
(1)
where, K is the thermal conductivity of composite in W/mK;
Q is the heat supplied in watts;
A is the area of the specimen in m2;
d is the thickness of the specimen in m.
Figure 3. Schematic Diagram of the set up. A: Copper base plate each 50 mm square 5 mm thick; B: Specimen 25 mm dia and 2 mm thick; C: Two halves of a copper cup 25 mm dia, outer height 5 mm and inner height 3 mm; D: Aluminium foils pads; H: Heater made up of six 120 ohm 1/4 W resistors in parallel; E: Cu-Constantan thermocouples.
Table 1. Thermal conductivity of epoxy and its composites.
2.5. Theoretical Models
The following analytical models were used to predict the thermal conductivity of epoxy composites [11] [12] . The models considered were Maxwell equation, cylinder assemblage model developed by Hashin Nielsen’s equation and series equation, which is an inverse rule of mixtures which gives lower bound values of thermal conductivity for particulate filled composites [12] .
a) Maxwell Equation
(2)
where K, Kc and Kd are the thermal conductivities of composites, matrix and fillers Φ is the volume fraction of filler.
b) Cylinder assemblage model: Cylinder Assemblage model was developed by Hashin
(3)
where, KT, KTM and KTF are thermal conductivities of composite, matrix and filler.
VF, VM are the volume fraction of filler and matrix.
c) Nielsen’s Equation
where
and (4)
where A is the geometry of the particles = 1.5 and (maximum packing fraction)
d) Inverse rule of mixtures/Series
(5)
The above equation is derived from rule of mixtures and does not consider voids.
3. Results and Discussion
3.1. Effect of Gr/SiC on Thermal Conductivity of Gr-Epoxy/SiC-Epoxy Composites
The experimental thermal conductivity and predicted by analytical models of all types of epoxy composites is listed in Table 1. Figure 4(a) and Figure 4(b) presents the thermal conductivity of epoxy composites filled with particulates of Gr and SiC. Neat epoxy exhibits a thermal conductivity of 0.30 W/mK. For filled Gr/SiC epoxy, up to 10% filler fraction, the rise in thermal conductivity is not significant. The epoxy composites containing 10% fillers, 10G-Ep and 10S-Ep exhibits a thermal conductivity of 0.32 W/mK and 0.33 W/mK respectively which is an insignificant improvement over neat epoxy. This may be due to low filler fraction and hence effective conductive paths are not created in the composite. Further addition of particulates of graphite increases thermal conductivity of graphite epoxy composites linearly. The thermal conductivity increases to 0.46 W/mK and 0.54 W/mK for 20G-Ep and 30G-Ep respectively. Maxima of 0.64 W/mK was observed for 40G-Ep which is an improvement of 113% over unfilled epoxy. The effect of adding SiC to epoxy is shown in Figure 4(b). The SiC-epoxy composites have trends similar to Gr-epoxy composites. However, 20S-Ep and 30S-Ep have thermal conductivity of 0.41 W/mK and 0.51 W/mK respectively which is marginally lower than Gr-epoxy under similar loading. However 40S-Ep, exhibits a thermal conductivity of 0.68 W/mK. This suggests that even though the thermal conductivity of SiC (280 W/mK) is higher than Gr (85 W/mK), SiC-Ep composites have lower thermal conductivity than Gr-Ep composites. The factors such as larger particle size of Gr (20 - 60 μm) (Figure 1(b)) irregularity in shape, easy dispersibility [11] favors enhancement of thermal conductivity, where as SiC particulates are smaller in size (6 - 12 μm) uniform (Figure 1), are not beneficial in creating conductive paths [8] [9] .
(a) (b)
Figure 4. Thermal conductivity of Gr/SiC filled epoxy. (a) Gr filled epoxy; (b) SiC filled epoxy.
Comparing thermal conductivity experimental with thermal conductivity predicted by analytical equations, it is seen that, series equation predicts lower thermal conductivity for all filler loadings where as Hashin and Maxwell equations are closer to experimental values. The prediction by Nielsen’s equation is in agreement with experimental value up to 20% filler loading and deviates after 30% filler fraction. This is in agreement with [3] [5] , where the Nielsen’s estimation at lower volume fraction matches the experimental values and tends to over estimate the thermal conductivity of composites at higher volume fraction.
3.2. Effect of Gr on Thermal Conductivity of Hybrid (Gr-SiC)-Epoxy Composites
The effect of varying Gr on hybrid (Gr-SiC) epoxy composites is shown in Figure 5(a) and Figure 5(b). Figure 5(a) shows the thermal conductivity of epoxy composites, where SiC was unvaried at 5% for all composites, Gr varied from 5% to 35% in steps of 10%. Increased Gr fraction increases the thermal conductivity of hybrid (Gr-SiC) epoxy composites. Thermal conductivity increases to 0.46 W/mK for 5S15G-Ep, 0.52 W/mK for 5S25G-Ep and 0.64 W/mK for 5S35G-Ep composite.
The effect of Gr where SiC is held at 10% and Gr is varied from 10% to 30% is shown in Figure 5(b). These composites present a trend similar to previous compositions. However, these composites exhibits marginally lower conductivity values than composites having 5% SiC unvaried composites. Maximum thermal conductivity of 0.62 W/mK was observed for 10S30G-Ep. The SEM of the surfaces of 5S35G-Ep and 10S30G-Ep is shown in Figure 6(a) and Figure 6(b) respectively. The few bright spots seen in the images are particulates of SiC.
3.3. Effect of SiC on Thermal Conductivity of Hybrid (Gr-SiC)-Epoxy Composites
Figure 7(a) and Figure 7(b) illustrates the effect of varying SiC and holding Gr constant at 5%, 10% respectively on hybrid (Gr-SiC) epoxy composites. Thermal conductivity increases linearly for all type of composites. The thermal conductivity increases to 0.52 W/mK for 5G25S-Ep and 0.62 W/mK for 5G35S-Ep. Similarly 10G20S-Ep and 10G30S-Ep exhibits thermal conductivity of 0.54 W/mK and 0.62 W/mK respectively. The SEM images of 5G35S-Ep and 10G30S-Ep composites are shown in Figure 8(a) and Figure 8(b). As SiC fraction is more for these composites, more bright spots are seen, indicating well distribution of SiC.
3.4. Effect of Equal Fraction of Gr and SiC on Thermal Conductivity of Hybrid (Gr-SiC)-Epoxy Composites
The effect of hybrid (Gr-SiC) fillers on epoxy where both fillers are equally varied is shown in Figure 9. The thermal conductivity of 10G10S-Ep is found to be 0.51 W/mK which is highest among 20% filled composites. Similarly 15G15S-Ep exhibits a thermal conductivity of 0.58 W/mK, highest among 30% filled epoxy. Similarly the thermal conductivity of 20G20S-Ep is 0.71 W/mK, highest among 40% filled composites. Further, it is also observed that for the same filler loadings, the thermal conductivity varies. As filler loading increases, number of interfaces increases and thermal conductivity in a polymer composite is dependent on good interfacial adhesion. For a poor interfacial adhesion phonon scattering increases, and decreases the thermal conductivity. Further dif-
(a) (b)
Figure 5. Thermal conductivity of graphite rich hybrid (Gr-SiC) epoxy composites. (a) SiC constant at 5%, Gr varied from 5% - 35%; (b) SiC constant at 10%, Gr varied from 10% - 30%.
(a) (b)
Figure 6. SEM images of surface of graphite rich hybrid (Gr-SiC) epoxy composites. (a) 5S35G-Ep; (b) 10S30G-Ep.
(a) (b)
Figure 7. Thermal conductivity of SiC rich hybrid (Gr-SiC) epoxy composites. (a) Gr constant at 5%, SiC varied from 5% - 35%; (b) Gr constant at 10%, SiC varied from 10% - 30%.
(a) (b)
Figure 8. SEM images of surface of graphite rich hybrid (Gr-SiC) epoxy composites. (a) 5G35S-Ep; (b) 10G30S-Ep.
Figure 9. Effect of fillers on thermal conductivity of epoxy composites. Both Gr and SiC varied equally.
ferent particle sizes vary the interfaces along the heat transfer path [13] . From the above it is evident that synergy exists between hybrid (Gr-SiC) when both the fillers are loaded equally.
4. Conclusion
Thermal conductivity increases linearly with increased filler fraction for all composite systems irrespective of fillers. Thermal conductivity show significant increase after 20% filler fraction. Comparing Gr-Ep and SiC-Ep composites, for the same filler fraction, Gr-Ep composites have higher thermal conductivity than SiC-Ep composites except for 40S-Ep which has higher thermal conductivity than 40G-Ep. Hybrid composites having equal proportion of filler fraction i.e. 10G10S-Ep, 15G15S-Ep and 20G20S-Ep have thermal conductivity highest in 20%, 30% and 40% filled epoxy composites. The hybrid composite 20G20S-Ep has a thermal conductivity of 0.71 W/mK which is highest among all the composite considered in this study and is an improvement of 136% over a neat epoxy. The experimental results were compared with the analytical models. The experimental results exhibit good correlation with Maxwell’s equation.
Acknowledgements
The authors thank the management of Don Bosco Institute of Technology, RajaRajeswari College of Engineering Bangalore and Indian Academy Of Science. Bangalore.
NOTES
*Corresponding author.