Simultaneous Determination of Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD5) in Wastewater by Near-Infrared Spectrometry
Qiong YANG, Zhenyao LIU, Jidong YANG
.
DOI: 10.4236/jwarp.2009.14035   PDF    HTML     14,995 Downloads   31,482 Views   Citations

Abstract

To rapidly determine the pollution extent of wastewater, the calibration models were established for deter-mination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater by partial least squares and near infrared spectrometry of 120 samples. Spectral data preprocessing and outliers’ diagnosis were also discussed. Correlation coefficients of the models were 0.9542 and 0.9652, and the root mean square error of prediction (RMSEP) were 25.24 mg?L-1 and 12.13 mg?L-1 in the predicted range of 28.40~528.0 mg?L-1 and 16.0~305.2 mg?L-1 for Chemical Oxygen Demand and Biological Oxygen Demand, respectively. By statistical significance test, the results of determination were compared with those of stan-dard methods with no significant difference at 0.05 level. The method has been applied to simultaneous de-termination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater with satisfactory results.

Share and Cite:

Q. YANG, Z. LIU and J. YANG, "Simultaneous Determination of Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD5) in Wastewater by Near-Infrared Spectrometry," Journal of Water Resource and Protection, Vol. 1 No. 4, 2009, pp. 286-289. doi: 10.4236/jwarp.2009.14035.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Chinese government standard GB11914-1989, “Determination of COD in water by dichromate titration method [S].”
[2] J. G. Zhan, G. Wei, and R. C Xiong, “Quick evaluation of chemical oxygen demand based on spectrophotomet-ric and multi-linear analysis [J],” Journal of Beijing University of Chemical Technology (Natural Science Edition), Vol. 34, No. 7, pp. 389–392, 2007. (In Chinese).
[3] H. B. Yu, H. Wang, et al., “Amperometric determination of chemical oxygen demand using boron-doped diamond (BDD) sensor [J],” Electrochemistry Communications, Vol. 9, No. 9, pp. 2280–2285, 2007.
[4] Kwok Nga-Yan, S. J. Dong, and W. H. Lo, “An optical biosensor for multi-sample determination of biochemical oxygen demand (BOD) [J],” Sensors and Actuators B: Chemical, Vol. 110, No. 2, pp. 289–298, 2005.
[5] D. M. Reynolds and S. R. Ahmad, “Rapid and direct determination of wastewater BOD values using a fluo-rescence technique [J],” Water Research, Vol. 31, No. 8, pp. 2012–2018, 1997.
[6] Y. L. Yan, “Basic and application of Near Infrared Spec-tra [M],” Beijing: China light industry publishing com-pany, Vol. 3, 2005.
[7] Chinese government standard GB7488-1987, “Determi-nation of BOD5 in water by dilute and inoculation method [S].”
[8] L. Xu and X. G. Shao, “Chemomtrics [M],” Beijing: Sci-ence publishing company, Vol. 258, 2004.
[9] S. Weisberg, “Applied Linear Regression [M],” New York: John Wiley & Sons. Vol. 168, 1985.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.