Comprehensive Benefit Analysis of Direct Expansion Ground Source Heat Pump System

Abstract

Direct Expansion Ground Source Heat Pump (DXGSHP) system directly extracts heat or cold energy from ground by consuming electricity to provide for space conditioning. Compared with the currently widely-used secondary loop Ground Couple Heat Pump (GCHP) system, it has higher energy efficiency, lower operating costs, and less environmental impact. A case study is carried out in this paper. The subject is a residential building located in Beijing, China. It is assumed that the building adopts the DXGSHP system and the GCHP system respectively. Annual loads and energy consumption are simulated and computed. Then the initial cost, operating cost and CO2 emission are calculated. The economic benefit is analyzed with the Payback Time method and the Dynamic Annual Cost Value method. The environmental benefit is discussed mainly by comparing the CO2 emission savings. The results show that the DXGSHP system has higher initial costs, but lower operating costs, and less greenhouse gas emissions. The DXGSHP system has better comprehensive benefits than the GCHP system.

Share and Cite:

Y. Gao, Y. Peng and J. Liu, "Comprehensive Benefit Analysis of Direct Expansion Ground Source Heat Pump System," Energy and Power Engineering, Vol. 5 No. 2A, 2013, pp. 76-81. doi: 10.4236/epe.2013.52A009.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] J. R. Goulburn and J. Fearon, “Deep Ground Coil Evaporators for Heat Pumps,” Applied Energy, Vol. 4, No. 4, 1978, pp. 293-313. doi:10.1016/0306-2619(78)90028-4
[2] J. R. Goulburn and J. Fearon, “Domestic Heat Pump with Deep Hole Ground Source Evaporator,” Applied Energy, Vol. 14, No. 2, 1983, pp. 99-113. doi:10.1016/0306-2619(83)90012-0
[3] J. Y. Lee, “Current Status of Ground Source Heat Pumps in Korea,” Renewable and Sustainable Energy Reviews, Vol. 13, No. 6-7, 2009, pp. 1560-1568. doi:10.1016/j.rser.2008.10.005
[4] B. Sanner, C. Karytsas, D. Mendrinos and I. Rybach, “Current Status of Ground Source Heat Pumps and underground Thermal Energy Storage in Europe,” Geothermics, Vol. 32, No. 4-6, 2003, pp. 579-588. doi:10.1016/S0375-6505(03)00060-9
[5] E. Hikmet, M. Inalli and M. Esen, “A Techno-Economic Comparison of Ground-Coupled and Air-Coupled Heat Pump System for Space Cooling,” Building and Environment, Vol. 42, No. 5, 2007, pp. 1955-1965. doi:10.1016/j.buildenv.2006.04.007
[6] P. F. Healy and V. I. Ugursal, “Performance and Economic Feasibility of Ground Coupled Heat Pumps in Cold Climate,” International Journal of Energy Research, Vol. 21, No. 10, 1997, pp. 857-870. doi:10.1002/(SICI)1099-114X(199708)21:10<857::AID-ER279>3.0.CO;2-1
[7] P. J. Petit and J. P. Meyer, “A Techno-Economic Analytical Comparison of the Performance of Air-Coupled and Horizontal-Ground Coupled Air Conditioners in South Africa,” International Journal of Energy Research, Vol. 21, No. 11, 1997, pp. 1011-1021. doi:10.1002/(SICI)1099-114X(199709)21:11<1011::AID-ER307>3.0.CO;2-L
[8] P. J. Petit and J. P. Meyer, “Economic Potential of Ground Coupled Heat Pumps Compared to Air-Coupled Air Conditioners in South Africa,” Energy, Vol. 23, No. 2, 1998, pp. 137-143. doi:10.1016/S0360-5442(97)00057-1
[9] Y. Genchi, Y. Kikegawa and A. Inaba, “CO2 Payback Time Assessment of a Regional-Scale Heating and Cooling System Using a Ground Coupled Heat-Pump in a High Energy-Consumption Area in Tokyo,” Applied Energy, Vol. 71, No. 3, 2002, pp. 147-160. doi:10.1016/S0306-2619(02)00010-7
[10] J. Liang, Q. C. Yang, L. C. Liu and X. Y. Li, “Modeling and Performance Evaluation of Shallow Ground Water Heat Pumps in Beijing Plain, China,” Energy and Buildings, Vol. 43, No. 11, 2011, pp. 3131-3138. doi:10.1016/j.enbuild.2011.08.007
[11] W. Yang, J. Zhou, W. Xu and G. Q. Zhang, “Current Status of Ground-Source Heat Pumps in China,” Energy Policy, Vol. 38, No. 1, 2010, pp. 323-332. doi:10.1016/j.enpol.2009.09.021
[12] X. D. Zhang, Y. Q. Jiang and Y. Yao, “Improved Method and Case Study of Ground-Coupled Heat Pump System Design,” Energy Procedia, Vol. 16, 2012, pp. 849-855. doi:10.1016/j.egypro.2012.01.136
[13] Y. H. Guo, G. Q. Zhang, J. Zhou, J. S. Wu and W. Shen, “Design and Performance of a Direct Expansion Ground Source Heat Pump System,” Journal of Chongqing University, Vol. 34, 2011, pp. 52-56.
[14] D. Banks, “An Introduction to Thermogeology: Ground Source Heating and Cooling,” Blackwell Publishing Ltd., Oxford, 2008. doi:10.1002/9781444302677
[15] Y. H. Guo, G. Q. Zhang, J. Zhou, J. S. Wu and W. Shen, “A Techno-Economic Comparison of a Direct Expansion Ground-Source and a Secondary Loop Ground-Coupled Heat Pump System for Cooling in a Residential Building,” Applied Thermal Engineering, Vol. 35, 2012, pp. 29-39. doi:10.1016/j.applthermaleng.2011.09.032
[16] X. H. Shen, “The Economy Analysis of Ground-Source Heat Pump Technology in Chengdu Area,” Modern Business Trade Industry, Vol. 17, 2009, pp. 304-306. (in Chinese)

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.