Fractured Metal Wire in the Right Ventricle, a Cause of Cardiac Tamponade
Mohamed Shafik Hashim, Dennis Elchanon Feierman
.
DOI: 10.4236/ojanes.2012.21002   PDF    HTML   XML   5,380 Downloads   8,769 Views   Citations

Abstract

Cardiac tamponade is a surgical emergency. This case report illustrates a very peculiar situation, where the patient’s condition deteriorated rapidly after arrival to the emergency room with a diagnosis of cardiac tamponade. Patient was promptly taken to the operating room and after evacuation of the pericardial effusion, had to be placed on cardio-pulmonary bypass in order to find and treat the source of the bleeding. A wire fragment was recovered from the right ventricle. This was identified as a broken piece of a guide wire used in placing a central venous catheter several years earlier.

Share and Cite:

M. Hashim and D. Feierman, "Fractured Metal Wire in the Right Ventricle, a Cause of Cardiac Tamponade," Open Journal of Anesthesiology, Vol. 2 No. 1, 2012, pp. 7-9. doi: 10.4236/ojanes.2012.21002.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] D. C. McGee and M. K. Gould, “Preventing Complications of Central Venous Catheterization,” New England Journal of Medicine, Vol. 348, No. 12, 2003, pp. 1123- 1133. doi:10.1056/NEJMra011883
[2] F. Castaneda, M. Herrera, A. H. Cragg, E Salamonowitz, G. Lund, W. R. Castaneda-Zuniga and K. Aplatz, “Migration of a Kimray-Greenfield Filter to the Right Ventricle,” Radiology, Vol. 149, No. 3, 1983, p. 690.
[3] G. M. Actia Dato, A. Arslanian, P. Di Marzio, P. L. Filosso and E. Ruffini, “Posttraumatic and Iatrogenic Foreign Bodies in the Heart: Report of Fourteen Cases and Review of the Literature,” Journal of Thoracic and Cardiovascular Surgery, Vol. 126, No. 2, 2003, pp. 408-414. doi:10.1016/S0022-5223(03)00399-4
[4] I, Saeed, M, Garcia and K. McNicholas, “Right Ventricular Migration of a Recovery IVC Filter’s Fractured Wire with Subsequent Pericardial Tamponade,” CardioVascular and Intervention al Radiology, Vol. 29, No. 4, 2006,, pp. 685-686. doi:10.1007/s00270-005-0136-7
[5] T. Suzuki, K. Ito, J. Nishiyama, K. Hasegawa, M. Kanazawa and H. Fukuyama, “Development of a Safe Guide wire,” Journal of Anesthesia, Vol. 20, No. 1, 2006, pp. 64-67. doi:10.1007/s00540-005-0361-x
[6] H, Arjomand, S, Surabhi and N. M. Wolf, “Right Ventricular Foreign Body: Percutaneous Transvenous Retrie- val of a Greenfield Filter from the Right Ventricle—A Case Report,” Angiology, Vol. 54, No. 1, 2003, pp. 109- 113. doi:10.1177/000331970305400114
[7] P. Rasuli, R. Mehran, G. French, M. Turek, K. A. Lalonde and P. Cardinal, “Percutaneous Retrieval of a Vena Cava Filter from the Right Atrium: Case Report,” Canadian Association of Radiologists Journal, Vol. 51, No. 1, 2000, pp. 30-35.