QBC ParaLens TM LED fluorescent microscope attachment with QBC F.A.S.T.TM AFB staining system

Abstract

This study was designed to evaluate the QBC ParaLensTM LED fluorescent microscope attachment and the QBC F.A.S.T.TM AFB staining system for the detection of Acid Fast Bacilli in pathological samples in Abidjan, Cote d’Ivoire. A total of 50 patients were tested using direct smear specimens with both Ziehl-Neelsen (ZN) light microscopy and LED fluorescence microscopy with QBC F.A.S.T. AFB stain. The samples were also cultured and tested using an immunochromatograpic test for detection of antigen MPT 64 and the results were compared to direct examination. ZN light microscopy detected 20 positive cases and LED fluorescent microscopy with QBC F.A.S.T. AFB stain detected 21. The sensitivity and specificity of ZN light microscopy was determined to be 84.2% and 87.1% respectively. The sensitivity and specificity of LED fluorescent microscopy with QBC F.A.S.T. AFB stain was determined to be 94.7% and 90.3% respectively. Compared to ZN light microscopy, LED fluorescent microscopy with QBC F.A.S.T. AFB stain increased the sensitivity of direct examination without concentration by 10.5%.

Share and Cite:

N’Guessan, K. , Hnatkovich, B. , Aka, N. , Achy-Brou, A. , Coulibaly, B. , Assande, J. , Mohoudi, P. and Dosso, M. (2013) QBC ParaLens TM LED fluorescent microscope attachment with QBC F.A.S.T.TM AFB staining system. Journal of Tuberculosis Research, 1, 40-43. doi: 10.4236/jtr.2013.13008.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Salfinger, M. and Pfyffer, G.E. (1994) The new diagnostic mycobacteriology laboratory. European Journal of Clinical Microbiology & Infectious Diseases, 13, 961-979. http://dx.doi.org/10.1007/BF02111498
[2] Steingart, K.R., Henry, M., Ng, V., Hopewell, P.C., Ramsay, A., Cunningham, J., Urbanczik, R., Perkins, M., Aziz, M.A. and Pai, M. (2006) Fluorescence versus conventional sputum smear microscopy for tuberculosis: A systematic review. The Lancet Infectious Diseases, 6, 570-581. http://dx.doi.org/10.1016/S1473-3099(06)70578-3
[3] Affolabi, D., Torrea, G., Odoun, M., Senou, N., Ali, L.M., Anagonou, S. and Van Deun, A. (2010) Comparison of two LED fluorescence microscopy build-on modules for acid-fast-bacilli smear microscopy. The International Journal of Tuberculosis and Lung Disease, 14,160-164.
[4] Kuhn, W., Armstrong, D., Atteberry, S., Dewbrey, E., Smith, D. and Hooper, N. (2010) Usefulness of the Paralens fluorescent microscope adaptor for the identification of mycobacteria in both field and laboratory settings. The Open Microbiology Journal, 4, 30-33. http://dx.doi.org/10.2174/1874285801004010030
[5] Nguyen, V.H., Dinh, N.S., Anthony, R.M., Cobelens, F.G. and van Soolingen, D. (2007) Fluorescence microscopy for tuberculosis diagnosis. The Lancet Infectious Diseases, 7, 238-239. http://dx.doi.org/10.1016/S1473-3099(07)70059-2
[6] Marais, B.J., Brittle, W., Painczyk, K., Hesseling, A.C., Beyers, N., Wasserman, E., van Soolingen, D. and Warren, R.M. (2008) Use of light-emitting diode fluorescence microscopy to detect acid fast bacilli in sputum. Clinical Infectious Diseases, 47, 203-207. http://dx.doi.org/10.1086/589248
[7] World Health Organization (1998) Laboratory services in tuberculosis control. Part II: Microscopy. WHO/TB/ 98.258. WHO, Geneva.
[8] Van Deun, A., Salim, A.H., Cooreman, F., Daru, P., Das, A.P., Anug, K.J.M. and Reider, H.L. (2004) Scanty AFB smears: What’s in a name? The International Journal of Tuberculosis and Lung Disease, 8, 816-823.
[9] Lawson, L., Yassin, M.A., Ramsay, A., Emenyonu, N.E., Squire, S.B. and Cuevas, L.E. (2005) Comparison of scanty AFB smears against culture in an area with high HIV prevalence. The International Journal of Tuberculosis and Lung Disease, 9, 933-935.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.