American Journal of Analytical Chemistry

Volume 7, Issue 12 (December 2016)

ISSN Print: 2156-8251   ISSN Online: 2156-8278

Google-based Impact Factor: 1.71  Citations  h5-index & Ranking

Study on the Temperature of the Bridge Wire in the Initiator Used in Nuclear Explosion Valve

HTML  XML Download Download as PDF (Size: 811KB)  PP. 908-917  
DOI: 10.4236/ajac.2016.712077    1,529 Downloads   2,766 Views  Citations

ABSTRACT

This paper established the mathematical model of bridge wire temperature rise under direct current condition and gave the solution. It computed bridge wire temperature by using the thermal-electric coupling method provided by ANSYS-Workbench finite element analysis software. In the end, the temperature bridge wire applied to different electric current was measured by the infrared thermal imaging temperature measurement method. The result shows that the ANSYS simulation results are in agreement with the theoretical calculation and the experimental results. It is feasible to compute bridge wire temperature of initiator by using ANSYS-Workbench software, and it is an important method to analyze complex structure of pyrotechnics.

Share and Cite:

Shi, L. , Yang, A. , Zhang, Y. , Wang, Y. and Li, Z. (2016) Study on the Temperature of the Bridge Wire in the Initiator Used in Nuclear Explosion Valve. American Journal of Analytical Chemistry, 7, 908-917. doi: 10.4236/ajac.2016.712077.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.