Materials Sciences and Applications

Volume 6, Issue 11 (November 2015)

ISSN Print: 2153-117X   ISSN Online: 2153-1188

Google-based Impact Factor: 0.97  Citations  

The Effect of the Light Intensity and Light Distances of LED and QTH Curing Devices on the Hardness of Two Light-Cured Nano-Resin Composites

HTML  XML Download Download as PDF (Size: 1777KB)  PP. 1071-1083  
DOI: 10.4236/msa.2015.611106    5,409 Downloads   8,216 Views  Citations

ABSTRACT

Background: Effective polymerization of the composite resin is essential to obtain long term clinical success and has a great importance obtaining improved mechanical properties. The purpose of this study was to measure the effect of the light intensity of LED and QTH curing devices in relation to the light distances, on the hardness (KHN) of two light cure nano-resin composite. Material and Methods: The top and bottom surfaces of the two nanofill composite specimens were evaluated. Two LED and two QTH light curing devices were used at nine different distances. Light intensity was measured with two radiometers placed at these same distances from the curing tip. 360 pvc dies were prepared with circular cavity 3 mm in diameter and 2 mm thick. The tested materials were placed in each cavity. The different light curing distances were standardized by adding pvc spacers dies at different height matching the different distances. Top and bottom surface microhardness were evaluated with a Micro Hardness Tester in knoop hardness numbers (Kg/mm2). Data were statistically analyzed using: Three-way ANOVA, Tukey and Pearsons test. Results: It was revealed that there was a statistically significant difference in microhardness between the composites (p < 0.001), between the nine distances (p < 0.001) and between the four light curing devices (p < 0.001). Increasing the distance of the light source from composite resin, the light intensity and the microhardness values at the top and bottom surface decrease. LED light curing devices produced a greater microhardness results at the bottom surface of the specimens. The Filtek Ultimate nanocomposite (3 m) showed highest microhardness values on the top and bottom surfaces, polymerized with all four curing devices and all nine distances compared to Empress Direct nano composite (Ivoclar vivadent). Clinical significant: Even with high power LED curing light, the distance between the tip of the light source and the restoration surface should be as close as possible. In this study, Filtek Ultimate showed better results (highest microhardness values) than Empress Direct.

Share and Cite:

Segal, P. , Lugassy, D. , Mijiritsky, E. , Dekel, M. , Ben-Amar, A. , Ormianer, Z. and Matalon, S. (2015) The Effect of the Light Intensity and Light Distances of LED and QTH Curing Devices on the Hardness of Two Light-Cured Nano-Resin Composites. Materials Sciences and Applications, 6, 1071-1083. doi: 10.4236/msa.2015.611106.

Cited by

[1] Effect of Light Curing Distance on Microhardness Profiles of Bulk-Fill Resin Composites
Polymers, 2022
[2] Evaluation of Degree of Conversion of Different Types of Bulk-fill Resin Composites
Jadwaa… - Journal of Global …, 2022
[3] A influência da distância da fonte de luz fotopolimerizadora no sucesso de uma restauração em resina composta
2022
[4] Valoración de la intensidad de luz emitida por unidades de fotopolimerización en consultorios odontológicos de Cerro Colorado, Arequipa 2021
2021
[5] Cuenca, Ecuador
2021
[6] Effect of different curing times and distances on the microhardness of nanofilled resin-based composite restoration polymerized with high-intensity LED light …
2021
[7] EFEITO DA DISTÂNCIA DO FOTOPOLIMERIZADOR À RESTAURAÇÃO DE RESINA COMPOSTA
2020
[8] Mechanical Properties of Recent Bulk-fill resin Composites
2020
[9] Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador
2020
[10] Mechanical Performance of Dental Resin Material after 10 Seconds or 40 Seconds Curing Time
Doctoral Thesis, 2020
[11] Power Up Your Posterior Composites
Dental Products Report, 2020
[12] Evaluación de la intensidad lumínica generada por lámparas de fotopolimerización utilizadas en consultorios privados de la ciudad de Cuenca. 2018
2019
[13] Resin based restorative dental materials: characteristics and future perspectives
2019
[14] ПРИМЕНЕНИЕ МОДУЛИРОВАННОГО ДИОДНОГО СВЕТА В СИНЕЙ ОБЛАСТИ СПЕКТРА ДЛЯ ОТВЕРЖДЕНИЯ ФОТОКОМПОЗИТОВ ПРИ ЛЕЧЕНИИ КАРИЕСА
2018
[15] Effects of distance from tip of LED light-curing unit and curing time on surface hardness of nano-filled composite resin
Journal of Physics: Conference Series, 2017
[16] Don't take light curing for granted: Improper curing can lead to failure
2017
[17] Don't take light curing for granted: Improper curing can lead to failure Dec. 5, 2017 Dental light curing is so much more than waving a blue LED over a …
[18] Als Dissertation genehmigt von der Medizinischen Fakultät der Friedrich-Alexander-Universität Erlangen-Nürnberg
[19] ПРИМЕНЕНИЕ МОДУЛИРОВАННОГО ДИОДНОГО СВЕТА В СИНЕЙ ОБЛАСТИ СПЕКТРА ДЛЯ ОТВЕРЖДЕНИЯ ФОТОКОМПОЗИТОВ ПРИ …

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.