Despite recent controversy, it is not yet formally recognised how lower-limb prosthesis should be assessed for their performance. To assist in this process, experiments are undertaken to investigate the linearity, stiffness and assessment of feet based energy return prosthesis technology typically used for elite level high speed running. Through initial investigations, it is concluded that static load testing would not be recommended to specify or regulate energy return prostheses for athletes with a lower-limb amputation. Furthermore, an assessment of energy return technology when loaded under dynamic conditions demonstrates changes in mechanical stiffness due to bending and effective blade length variation during motion. Such radical changes of boundary conditions due to loading suggest that any assessment of lower-limb prosthesis technology in the future should use methods that do not assume linear mechanical stiffness. The research into such effects warrants further investigation in the future.


Share and Cite:

Dyer, B. , Sewell, P. and Noroozi, S. (2013) How should we assess the mechanical properties of lower-limb prosthesis technology used in elite sport?—An initial investigation. Journal of Biomedical Science and Engineering, 6, 116-123. doi: 10.4236/jbise.2013.62015.

Cited by

[1] Designing Custom Mechanics in Running-Specific Prosthetic Feet via Shape Optimization
IEEE Transactions …, 2022
[2] Enhancing Biomechanical Function through Development and Testing of Assistive Devices for Shoulder Impairment and Total Limb Amputation
2021
[3] Properties of Materials and Models of Prosthetic Feet: A Review
2021
[4] Development of comfort fit lower limb prosthesis by reverse engineering and rapid prototyping methods and validated with gait analysis
2021
[5] ひずみ分布を考慮した競技用義足の反発特性の評価に関する研究
2020
[6] Development of Instrumented Running Prosthetic Feet for the Collection of Track Loads on Elite Athletes
2020
[7] 高速度撮影画像を用いたひずみの定量化による競技用義足の動的挙動評価
2020
[8] Conceptual design of a new multi-component test bench for the dynamic characterization of running specific prostheses
2020
[9] Measurement of Dynamic Behavior of Running-Specific Prostheses by an Impact Test
2020
[10] Innovative alignment of sprinting prostheses for persons with transfemoral amputation: Exploratory study on a gold medal Paralympic athlete
2020
[11] 走行中の衝撃を考慮した競技用義足の挙動計測に関する研究
2019
[12] 走行中の衝撃を考慮した競技用義足の反発特性の評価に関する研究
2019
[13] Methods for Describing and Characterizing the Mechanical Behavior of Running-Specific Prosthetic Feet
2019
[14] State-of-the-art cooling technology for a turbine rotor blade
2018
[15] Mechanical stiffness of running-specific prostheses in consideration of clamped position
Mechanical Engineering Letters, 2018
[16] Sport-Specific Limb Prostheses in Para Sport
Physical Medicine and Rehabilitation Clinics of North America, 2018
[17] Assessment of Mechanical Characteristics of Ankle-Foot Orthoses
Journal of Biomechanical Engineering, 2018
[18] 障がい者スポーツへの貢献~ 競技用義足を例にして~(< 特集> オリンピック・パラリンピックに貢献するスポーツ工学)
日本機械学会誌, 2018
[19] 衝撃試験による競技用義足の反発性能の評価に関する研究
2018
[20] 衝撃試験による競技用義足の動的挙動計測
2018
[21] An investigation of the effect of boundary conditions on the mechanical characteristics of an energy storing and returning prosthetic foot subject to non …
2017
[22] Technology Enhancement and Ethics In the Paralympic Games
2016
[23] Effect of Different Mounting Angles of Prosthetic Feet Dedicated to Sprinting on Reaction Forces
Procedia Engineering, 2016
[24] Development of a Wearable Sensor System for Dynamically Mapping the Behavior of an Energy Storing and Returning Prosthetic Foot
Measurement Science Review, 2016
[25] Characterisation of the responsive properties of two running-specific prosthetic models
2016
[26] Amputee Locomotion: Ground Reaction Forces During Submaximal Running With Running-Specific Prostheses
2016
[27] An Investigation into the Measurement and Prediction of Mechanical Stiffness of Lower-limb Prostheses used for Running
Assistive Technology, 2014
[28] Is knowledge of classifications and technology significant in the perception of fair play and audience interest in Paralympic sports requiring prosthetics?
2013
[29] Design and construction of a multichannel bench test for running specific prostheses

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.