[1]
|
Howie, D., McGee, M. (1996) Wear and osteolysis in relation to prostheses design and materials. Medical applications of Titanium and its alloys (ASTM STP 1272).
|
[2]
|
McGee, M., Howie, D., Neale, S., Haynes, D. and Pearcy, M. (1997) The role of polyethylene wear in joint replacement failure. Proceedings of the Institution of Mechanical Engineering, Part H: Journal of Engineering in Medicine, 211(1), 65-72.
doi:/10.1243/0954411971534692
|
[3]
|
Dowson, D., Wallbrigde, N. (1985) Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints: I: Charnley prostheses with polytetrafluoroethylene acetabular cups. Wear, 104(1), 203-215.
doi:/10.1016/0043-1648(85)90048-1
|
[4]
|
Zhou, Y., Ikeuchi, K. and Ohashi, M. (1997) Comparison of the friction properties of four ceramic materials for joint replacements. Wear, 210(1-2), 171-177.
doi:/10.1016/S0043-1648(97)00066-5
|
[5]
|
Wang, A., Polineni, V., Essner, A., Sokol, M., Sun, D., Stark, C. and Dumbleton, J. (1997) The significance of nonlinear motion in the wear screening of prthopaedic implants materials. Testing & Evaluation, 13, 239-245.
|
[6]
|
Wang, A., Stark, C. and Dumbleton, J. (1996) Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineerng, Part H: Journal of Engineering in Medicine, 210(3), 141-156.
|
[7]
|
Murray, D., Rushton, N. (1990) Macrophages stimulate bone resorption when they phagocytose particles. Journal of Bone and Joint Surgery, 72(6), 988-992.
|
[8]
|
Green, T., Fisher, J., Stone, M., Wroblewski, B. and Ingham, E. (2004) Polyethylene particles of a ‘critical size’ are necessary for the induction of cytokines by macrophages in vitro. Biomaterials, 19(24), 2297-2302.
doi:/10.1016/S0142-9612(98)00140-9
|
[9]
|
Doorn, P., Mirra, J., Campbell, P. and Amstutz, H. (1996) Tissue reaction to metal on metal total hip prostheses. Clinical Orthopaedics Related Research, 329, 187-205.
doi:/10.1097/00003086-199608001-00017
|
[10]
|
Gil, F.J., Manero, J.M. and Planell, J.A. (1995) TissueEffect of grain size on the martensitic transformation in NiTi alloy. Journal of Materials Science, 30(10), 2526-2530. doi:/10.1007/BF00362129
|
[11]
|
Gil, F.J., Planell, J.A. (1999) Effect of copper addition on the superelastic behavior of Ni-Ti shape memory alloys for orthodontic applications. Journal of Biomedical Materials Resesrch, 48(5), 682-688.
doi:/10.1002/(SICI)1097-4636(1999)48:5<682::AID-JBM12>3.0.CO;2-M
|
[12]
|
Viceconti, M. Cavallotti, G., Andrisano, A. and Toni, A. (1996) Discussion on the design of a hip joint simulator. Medical Engineering and Physics, 18(3), 234-240.
doi:/10.1016/1350-4533(95)00026-7
|
[13]
|
Wang, A., Essner, A., Polineni, V., Stark, C. and Dumbleton, J. (1998) Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribology International, 31(1-3), 17-33.
doi:/10.1016/S0301-679X(98)00005-X
|
[14]
|
Gil, F.J., Planell, J.A. (1998) Shape memory alloys for medical applications. Proceedings of the Institution of Mechanical Engineering, Part H: Journal of Engineering in Medicine, 212(6), 473-488.
doi:/10.1243/0954411981534231
|
[15]
|
Guilemany, J.M., Gil, F.J. (1991) Kinetic grain growth in Cu-Zn-Al shape memory alloys. Journal of Materials Science, 26(17), 4626-4630. doi:/10.1007/BF00612397
|