Solution Scheme for Time Synchronization of Current Differential Protection between Digital Substations

Abstract

In digital substations with power transformers, the key to implementation of line differential protection is synchronization of electrical quantities at both two sides. System framework of current differential protection for lines between digital substations is analyzed briefly, as well as the necessity of demand for time synchronization. Principle of time synchronization based on GPS and IEEE1588 PTP (Precision Time Protocol) are introduced. Time synchronization of current differential protection between digital substations based on IEC61850 is discussed. This paper puts forward two solution schemes of time synchronization, analyzes their advantages and disadvantages respectively, and points out that the development direction of time synchronization of differential protection between digital substations is IEEE1588 PTP.

Share and Cite:

B. Duan and Y. Wu, "Solution Scheme for Time Synchronization of Current Differential Protection between Digital Substations," Energy and Power Engineering, Vol. 5 No. 4B, 2013, pp. 463-467. doi: 10.4236/epe.2013.54B089.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] H. L. Gao, “Application of GPS in Electric Power System and its Orospects,” International Electric Power For China,Vol. 2, 1999, pp. 48-52.
[2] IEEE Instrumentation and Measurement Society. [IEEE1588]^TM v2.2 standard for a precision clock synchronization protocol for net worked measurement and control systems, New York, USA, IEEE 2008.
[3] J. C. Eidson, IEEE-1588 Standard Version 2-A Tutorial. Palo Alto, USA: Agilent Technologies, 2006.
[4] International Electrotechnical Commission. IEC61850 Communication networks and systems in substations, part 5; communication requirements for functions and device models. [S.I]: IEC, 2003.
[5] H. Y. Liu, H. T. Hao, Y. X. Li, et al., “Research on a Synchronism Scheme for Digital Substations,” Automation of Electric Power Systems, Vol. 33, No. 3, 2009, pp. 55-58.
[6] Z. L. Yin, “Synchronization of Sampled Values in Digital Substations,” East China Electric Power, Vol. 36, No. 7, 2008, pp. 38-41.
[7] H. L. Gao, S. F. Jiang and J. L. He, “Sampling Synchronization Methods in Digital Current Differential Protection,” Automation of Electric Power Systems, Vol. 20, No. 9, 1996, pp. 46 -49.
[8] T. J. Cao, J. Y. Chen and G. F. Huang, “A Study on Data Synch Ronization Method for Optical Fiber Differential Protection Based on IEC 61850-9,” Automation of Electric Power Systems, Vol. 33, No. 24, 2009, pp. 58-60.
[9] H. J. Liu, Y. M. Sun and Y. X. Li, “Performance Analysis and Research on Line Differential Protection in Digitized Substation,” Automation of Electric Power Systems, Vol. 32, No. 17, 2008, pp. 72-74.
[10] Y. H. Yu, D. N. Zhang and Y. H. Hu, et al., “Time Synchronizing System for Power System,” Automation of Electric Power Systems, Vol. 32, No. 7, 2008, pp. 82-86.
[11] B. Hirschler, “Practical Application of 1588 Security, IEEE International Symposium on Precision Clock Synchronization for Measurement,” Control and Communication, 2008.
[12] S. L. Zhao, M. Q. Hu, X. B. Dou, et al., “Research of Time Synchronization in Digital Substation Based on IEEE1588,” Power System Technology, Vol. 32, No. 21, 2008, pp. 97-102.
[13] X. Huang, Y. F. Wang, D. N. Zhang, et al., “IEC61588 Time Synchronization System and Security Evaluation for Smart Substations,” Automation of Electric Power Systems, Vol. 36, No. 13, 2012, pp. 76-80.
[14] R. F. Li, X. J. Zeng, Z. W. Li, et al., “Analysis and Correction Methods for Network Time-delay Error of IEEE1588 Synchronization Clock,” Automation of Electric Power Systems, Vol. 36, No. 12, 2012, pp. 82-87.
[15] D. S. Mohl, “IEEE1588-Precise Time Synchronization as the Basis for Real Time Applications in Automation,” Industrial Networking Solution, 2003.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.