Process of Designing Robust, Dependable, Safe and Secure Software for Medical Devices: Point of Care Testing Device as a Case Study

HTML  Download Download as PDF (Size: 1036KB)  PP. 1-13  
DOI: 10.4236/jsea.2013.69A001    4,380 Downloads   8,047 Views  Citations

ABSTRACT

This paper presents a holistic methodology for the design of medical device software, which encompasses of a new way of eliciting requirements, system design process, security design guideline, cloud architecture design, combinatorial testing process and agile project management. The paper uses point of care diagnostics as a case study where the software and hardware must be robust, reliable to provide accurate diagnosis of diseases. As software and software intensive systems are becoming increasingly complex, the impact of failures can lead to significant property damage, or damage to the environment. Within the medical diagnostic device software domain such failures can result in misdiagnosis leading to clinical complications and in some cases death. Software faults can arise due to the interaction among the software, the hardware, third party software and the operating environment. Unanticipated environmental changes and latent coding errors lead to operation faults despite of the fact that usually a significant effort has been expended in the design, verification and validation of the software system. It is becoming increasingly more apparent that one needs to adopt different approaches, which will guarantee that a complex software system meets all safety, security, and reliability requirements, in addition to complying with standards such as IEC 62304. There are many initiatives taken to develop safety and security critical systems, at different development phases and in different contexts, ranging from infrastructure design to device design. Different approaches are implemented to design error free software for safety critical systems. By adopting the strategies and processes presented in this paper one can overcome the challenges in developing error free software for medical devices (or safety critical systems).

Share and Cite:

S. Tulasidas, R. Mackay, P. Craw, C. Hudson, V. Gkatzidou and W. Balachandran, "Process of Designing Robust, Dependable, Safe and Secure Software for Medical Devices: Point of Care Testing Device as a Case Study," Journal of Software Engineering and Applications, Vol. 6 No. 9A, 2013, pp. 1-13. doi: 10.4236/jsea.2013.69A001.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.