Objectives: There is a risk of spreading infectious material via non-sterile impressions. The aim of this study was to compare the effect of autoclave sterilisation on dimensional stability and tear strength of impression materials. Methods: Twenty-four specimens were produced using a standard ruled test block for each of three impression materials (Affinis, Aquasil and Speedex) to test dimensional stability. Thirty tear strips for each material were prepared for the tear test (ISO 34-1). Specimens were randomly allocated to 3 different groups (autoclaved, disinfected or untreated). A non-contact scanner was used to analyse dimensional change and a universal testing machine was used to determine tear strengths. Results: There were no significant differences in the test dimensions measured for any of the three impression materials following autoclave treatment compared to the disinfected or untreated control groups. The tear strengths were not adversely affected by autoclave sterilisation at 134°C. Conclusion: These addition and condensation-cured silicone impression materials can be steam autoclaved without adverse effects on dimensional accuracy or tear strength.

Conflicts of Interest

The authors declare no conflicts of interest.

Cite this paper

Millar, B. and Deb, S. (2014) Effect of Autoclave Sterilisation on the Dimensional Stability and Tear Strength of Three Silicone Impression Materials. Open Journal of Stomatology, 4, 518-526. doi: 10.4236/ojst.2014.412069.

References

[1] Egusa, H., Watamoto, T., Matsumoto, T., Abe, K., Kobayashi, M., Akashi, Y. and Yatani, H. (2008) Clinical Evaluation of the Efficacy of Removing Microorganisms to Disinfect Patient-Derived Dental Impressions. International Journal of Prosthodontics, 21, 531-538.
[2] Giammanco, G.M., Melilli, D., Rallo, A., Pecorella, S., Mammina, C. and Pizzo, G. (2009) Resistance to Disinfection of a Polymicrobial Association Contaminating the Surface of Elastomeric Dental Impressions. New Microbiologica, 32, 167-172.
[3] Powell, G.L., Runnells, R.D., Saxon, B.A. and Whisenant, B.K. (1990) The Presence and Identification of Organisms Transmitted to Dental Laboratories. Journal of Prosthetic Dentistry, 64, 235-237.
http://dx.doi.org/10.1016/0022-3913(90)90185-F
[4] Pang, S.K. and Millar, B.J. (2006) Cross Infection Control of Impressions: A Questionnaire Survey of Practice among Private Dentists in Hong Kong. Hong Kong Dental Journal, 3, 89-93.
[5] Rath, C., Sharpling, W.D. and Millar, B.J. (2010) Review of the Provision of Crowns by Dentists in Ireland. Journal of the Irish Dental Association, 56, 178-185.
[6] Kugel, G., Perry, R.D., Ferrari, M. and Lalicata, P. (2000) Disinfection and Communication Practices: A Survey of U.C Dental Laboratories. Journal of the American Dental Association, 131, 786-792.
http://dx.doi.org/10.14219/jada.archive.2000.0278
[7] Blair, F.M. and Wassell, R.W. (1996) A Survey of the Methods of Disinfection of Dental Impressions Used in Dental Hospitals in the United Kingdom. British Dental Journal, 180, 369-375.
http://dx.doi.org/10.1038/sj.bdj.4809092
[8] Holtan, J.R., Olin, P.S. and Rudney, J.D. (1991) Dimensional Stability of a Polyvinylsiloxane Impression Material Following Ethylene Oxide and Steam Autoclave Sterilisation. Journal of Prosthetic Dentistry, 65, 519-525.
http://dx.doi.org/10.1016/0022-3913(91)90292-5
[9] Olin, P.S., Holtan, J.R., Breitbach, R.S. and Rudney, J.D. (1994) The Effects of Sterilization on Addition Silicone Impressions in Custom and Stock Metal Trays. Journal of Prosthetic Dentistry, 71, 625-630.
http://dx.doi.org/10.1016/0022-3913(94)90449-9
[10] Millar, B.J. (1999) Dimensional Stability of Additional Cured Silicone Impressions Following Autoclave Sterilization. Journal of Dental Research, 78, 297.
[11] Deb, S., Etemad-Shahidi, S. and Millar, B.J. (2014) Dimensional Stability of Autoclave Sterilised Addition Cured Impressions and Trays. European Journal of Prosthodontics and Restorative Dentistry, 22, 35-42.
[12] Mathyas, J., Dao, N., Caputo, A.A. and Lucatorto, F.M. (1990) Effects of Disinfectants on Dimensional Accuracy of Impression Materials. Journal of Prosthetic Dentistry, 64, 25-31.
http://dx.doi.org/10.1016/0022-3913(90)90148-6
[13] Ahmad, S., Tredwin, C.J., Nesbit, M. and Moles, D.R. (2007) Effect of Immersion Disinfection with Perform-ID on Alginate, an Alginate Alternative, an Addition-Cured Silicone and Resultant Type III Gypsum Casts. British Dental Journal, 202, 36-37.
[14] Bock, J.J., Fuhrmann, R.A. and Setz, J. (2008) The Influence of Different Disinfectants on Primary Impression Materials. Quintessence International, 39, 93-98.
[15] Melilli, D., Rallo, A., Cassaro, A. and Pizzo, G.I. (2008) The Effect of Immersion Disinfection Procedures on Dimensional Stability of Two Elastomeric Impression Materials. Journal of Oral Science, 50, 441-446.
http://dx.doi.org/10.2334/josnusd.50.441
[16] Mandikos, M.N. (1998) Polyvinyl Siloxane Impression Materials: An Update on Clinical Use. Australian Dental Journal, 43, 428-434.
http://dx.doi.org/10.1111/j.1834-7819.1998.tb00204.x
[17] Martin, N., Martin, M.V. and Jedynakiewicz, N. (2007) The Dimensional Stability of Dental Impression Materials Following Immersion in Disinfecting Solutions. Dental Materials, 23, 760-768.
http://dx.doi.org/10.1016/j.dental.2007.01.004
[18] Millar, B.J., Wood, D.J., Bubb, N.L. and Gabrielson, L. (1995) Tear Strength of Hydrophilic and Hydrophobic Polyvinylsiloxane Materials. Journal of Dental Research, 74, 881.
[19] Sofou, A., Larsen, T., Fiehn, N.E. and Owall, B. (2002) Contamination Level of Alginate Impressions Arriving at a Dental Laboratory. Clinical Oral Investigations, 6, 161-165.

  
comments powered by Disqus

Copyright © 2018 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.