False contouring effect of the uterine wall during hysteroscopy a lesson from immediate hydrosonography

DOI: 10.4236/ojog.2013.35A1001    2,738 Downloads   3,999 Views  

ABSTRACT

A 42 years old woman suffering from repeated events of intensive vaginal bleeding during the week off birth control pills was referred for diagnostic hysteroscopy. The patient underwent hysterohy drosonoscopy, a 3-step procedure, including a transvaginal ultrasound scan, a diagnostic hysteroscopy and immediate hydrosonography. A3 cmintramural myoma was detected by the ultrasound scan without impinging onto the uterine cavity as visualized by diagnostic hysteroscopy. However, continuous hydrosonographic evaluation of the uterus, performed immediately afterwards, unveiled a fibroid with a significant intracavitary portion. A falsely normal cavity could be appreciated by high pressured hysteroscopy, while during the gradual fall of the intracavitary pressure a significant lesion could be revealed encroaching into the lumen. In the absence of an agreed distention pressure range during hysteroscopy, an immediate hydrosonography may serve as an auxiliary tool to follow the uterine wall contour as distention pressure declines during the eventual escape of the distention fluid from the lumen. Uterine wall contour is heavily dependent on the distension pressure and guidelines for intrcavitary pressure during hysteroscopy are evidently needed.

Conflicts of Interest

The authors declare no conflicts of interest.

Cite this paper

Hamani, Y. , Voss, E. , Shushan, A. and Haimov-Kochman, R. (2013) False contouring effect of the uterine wall during hysteroscopy a lesson from immediate hydrosonography. Open Journal of Obstetrics and Gynecology, 3, 1-4. doi: 10.4236/ojog.2013.35A1001.

References

[1] Haimov-Kochman, R., Pshitizky, M., Hamani, Y., Hurwitz, A. and Voss, E. (2010) Hysterohydrosonoscopy— An integrated modality for uterine imaging. Gynecological Surgery, 7, 311-314. doi:10.1007/s10397-010-0576-1
[2] Baker, V.L. and Adamson, D.G. (1998) Minimum intrauterine pressure required for uterine distension. Journal of the American Association of Gynecologic Laparoscopists, 5, 51-53. doi:10.1016/S1074-3804(98)80011-X
[3] Lasmar, R.B., Barrozo, P.R., Dias, R. and Oliveira, M.A. (2005) Submucous myomas: A new presurgical classification to evaluate the viability of hysteroscopic surgical treatment—Preliminary report. Journal of Minimally Invasive Gynecology, 12, 308-311. doi:10.1016/j.jmig.2005.05.014
[4] Kolankaya, A. and Arici, A. (2006) Myomas and assisted reproductive technologies: When and how to act? Obstetrics & Gynecology Clinics of North America, 33, 145-152. doi:10.1016/j.ogc.2005.12.008
[5] Bettocchi, S., Siristatidis, C., Pontrelli, G., Di Spiezio Sardo. A., Ceci, O., Nappi, L. and Selvaggi, L. (2008) The destiny of myomas: Should we treat small submucous myomas in women of reproductive age? Fertility and Sterility, 90, 905-910. doi:10.1016/j.fertnstert.2007.09.015
[6] Sankaran, S. and Manyonda, I.T. (2008) Medical management of fibroids. Best Practice & Research Clinical Obstetrics & Gynaecology, 22, 655-676. doi:10.1016/j.bpobgyn.2008.03.001
[7] Fedele, L., Bianchi, S., Marchini, M., Mezzopane, R., Di Nola, G. and Tozzi, L. (1996) Residual uterine septum of less than 1 cm after hysteroscopic metroplasty does not impair reproductive outcome. Human Reproduction, 11, 727-729. doi:10.1093/oxfordjournals.humrep.a019242
[8] Rackow, B.W. and Arici, A. (2007) Reproductive performance of women with müllerian anomalies. Current Opinion in Obstetrics and Gynecology, 19, 229-237. doi:10.1097/GCO.0b013e32814b0649
[9] Ozgur, K., Isikoglu, M., Donmez, L. and Oehninger, S. (2007) Is hysteroscopic correction of an incomplete uterine septum justified prior to IVF? Reproductive BioMedicine Online, 14, 335-340. doi:10.1016/S1472-6483(10)60876-0
[10] Bozdag, G., Aksan, G., Esinler, I. and Yarali, H. (2008) What is the role of office hysteroscopy in women with failed IVF cycles? Reproductive BioMedicine Online, 17, 410-415. doi:10.1016/S1472-6483(10)60226-X
[11] Shirk, G.J. and Gimpelson, R.J. (1994) Control of intrauterine fluid pressure during operative hysteroscopy. Journal of the American Association of Gynecologic Laparoscopists, 1, 229-233. doi:10.1016/S1074-3804(05)81015-1
[12] Bajka, M., Weiss, S., Kunz, J., Fischer, H., Szkely, G. and Niederer, P. (2009) Pressure-dependent hydrometra dimensions in hysteroscopy. Surgical Endoscopy, 23, 2102-2109. doi:10.1007/s00464-008-0231-3
[13] Garry, R. (2010) Pressure-controlled hysteroscopy during menstruation. Journal of Minimally Invasive Gynecology, 17, 337-343. doi:10.1016/j.jmig.2010.01.009
[14] Siegler, A.M., Valle, R.F., Lindemann, H.S. and Mencaglia, L. (1990) Therapeutic hysteroscopy indication and techniques. CV Mosby, St. Louis.
[15] American College of Obstetricians and Gynecologists (2005) ACOG technology assessment in obstetrics and gynecology, number 4, August 2005: Hysteroscopy. Obstetrics & Gynecology, 106, 439-442.

  