Journal of Minerals and Materials Characterization and Engineering
Vol.07 No.05(2019), Article ID:95395,23 pages
10.4236/jmmce.2019.75022

Corrosion Performance of Conversion Treatments for Electrogalvanised Steel Sheet

A. R. Di Sarli1, C. I. Elsner1,2, L. E. M. Palomino3, C. R. Tomachuk1*

1Centro de Investigación y Desarrollo en Tecnología de Pinturas (CICPBA-CONICET-UNLP), La Plata, Argentina

2Facultad de Ingeniería, UNLP, La Plata, Argentina

3Environmental and Basic Sciences Department, Engineering School of Lorena, University of São Paulo, Lorena, Brazil

Copyright © 2019 by author(s) and Scientific Research Publishing Inc.

This work is licensed under the Creative Commons Attribution International License (CC BY 4.0).

http://creativecommons.org/licenses/by/4.0/

Received: August 7, 2019; Accepted: September 23, 2019; Published: September 26, 2019

ABSTRACT

Chromate conversion treatments have been widely used due to their excellent corrosion resistance properties; however, their use is increasingly restricted because of the highly toxic chromic acid solutions required, with consequent effluent disposal and ecological problems. The removal of these toxic chemicals is considered a priority within most of the developed countries. In this work, the corrosion resistance of different alternative pretreatments applied on electrogalvanised steel sheet: 1) Cr(III) and Zr complexes layer, 2) Ce(III) layer, 3) Ce(III)/Ce(IV) double layer, 4) Cr(VI) chromating was investigated, and its results compared with those from the tests performed using bare electrogalvanized steel sheets as a substrate. These samples were exposed to aerated 0.05 mol/L NaCl or 0.1 mol/L Na2SO4 solutions. The electrochemical behavior of samples was studied by electrochemical techniques. For three days of immersion in the solution test, the experimental results have shown that, compared with the Cr(VI) protective properties, the Cr(III) + Zr complex layer presented similar performance. Even though the initial corrosion resistance was offered by the Ce(III) and Ce(VI)/Ce(III) conversion coatings was relatively good, it quickly decreased as a function of the exposure time.

Keywords:

Pre-Treatments, Conversion Coatings, Corrosion, EIS, Electrogalvanised Steel

1. Introduction

The corrosion of electrogalvanised steel is one of the major problems in industry. The material could become more resistant to corrosion if a protective conversion coating is applied on top of the zinc layer. The term “conversion coating”, as used in the metal-finishing industry, refers to the conversion of a metal surface into a surface that will more easily accept applied coatings and/or provide a more corrosion resistant surface [1] . Conversion coatings for zinc have been in use since the early 1920’s and there are several different products on the market [2] - [16] . These layers protect the zinc coating by acting as a physical barrier to the inducing corrosion species (water, oxygen and ions), and corrosion inhibitor. Furthermore, when the surface is scratched or mechanically damaged, enough water is absorbed by the layer to swell and mend the damaged areas (self-healing effect) [17] .

The Cr(III)-based conversion coating technology was commercially introduced in the late 1980’s as an earlier attempt to replace the carcinogenic hexavalent chrome from as many metal-finishing processes as possible [18] - [32] . Tomachuk et al. [33] evaluated the corrosion behavior in zinc coatings obtained from a cyanide-free alkaline bath, then subjected to Cr(III)-based passivation treatments with or without sealing treatment and submerged in different electrolytes. The experimental data analysis allowed to infer that the Cr(III)-based conversion treatment with a suitable sealant provides good corrosion resistance. Also, that still performs better attached to a suitable painting system due to an increased amount of white corrosion products covering the surface micro-defects act as a barrier to oxygen and ionic species diffusion through the conversion layer. Furthermore, the Cr(III) layer also decreased the rate of the oxygen reduction reaction during oxidation of the zinc substrate.

As well, among the chromate-free and environmentally friendly pre-treatments developed so far, the application of Zr-based conversion coatings has gained acceptance [34] [35] [36] [37] . They are currently introduced in several industrial applications, such as in the automotive industry. Puomi et al. [38] showed that the Zr-based conversion coatings on galvanized steel and Galfan steel is mainly composed of ZrO2 and their thickness < 50 nm. The ZrO2 has very attractive properties, such as improved resistance to wear and corrosion, heat resistance and good adhesion to metallic surfaces [39] - [50] .

Hinton et al. made the first research on the rare earths salt-based treatments [9] [10] [51] . They found that cerium was effective in reducing the corrosion cathodic reaction. Other authors also investigated the mechanism of corrosion inhibition on zinc treated with Ce salts [52] - [58] . Aramaki [59] proposed modifying the Ce2O3 film usually formed on the treated surface, oxidizing with H2O2. The result was the formation of a highly resistant layer to the 0.5 mol/L NaCl solution. XPS (X-ray photoelectron spectroscopy) analysis showed the formation of a thin film (thickness < 50 nm) containing a small amount of Ce(IV) which is derived from the oxidation of Ce(III) by the H2O2. The coexistence of Ce(IV) is still investigated [60] . Shibli [61] , developed a nanoparticulate CeO2 film wherein Ce(NO3)3∙6H2O was incorporated into the zinc bath. The coating produced had a thickness of 50 µm; however the thickness of the CeO2 film was approximately 20 nm to 40 nm. Hamlaoui [62] investigated the electrodeposition of layers obtained from electrolytes based on cerium salts on galvanized steel. He found that the more concentrated solution to lower its pH and, therefore, working in highest concentration was vigorous bubbling confirming the presence of large amounts of H2↑. However, if the film was treated with cerium PEG (polyethylene glycol) after passivation, this reduced the number of cracks in the deposit by reducing the hydrogen present in the aqueous medium or by decreasing the film thickness. Montemor et al. [63] and Ferreira et al. [64] have studied the effect of treatment time on the chemical composition and corrosion behavior of Ce(NO3)3 conversion coatings for galvanized steel and found that the film composition and thickness change with time.

As an extensive research is still needed to find effective but non-toxic and environmentally friendly conversion treatments for replacing the based on Cr(VI), the aim of the present work was to study the protective performance of: 1) Cr(III) + Zr complex layer; 2) Ce(III) layer; 3) Ce(IV)/Ce(III) double layer; or 4) Cr(VI) chromating (as reference) applied on electrogalvanised steel sheets. For this, replicates of the coated sheets were immersed for 72 h in aerated 0.05 mol/L NaCl or 0.1 mol/L Na2SO4 solutions and their behavior investigated through AC (electrochemical impedance spectroscopy-EIS) and DC (potentiodynamic polarization) electrochemical techniques. The EIS data were fitted and interpreted by means of equivalent electrical circuit models.

2. Experimental Details

2.1. Preparation of Electrogalvanised and Passivated Samples

1) Panels of low-carbon steel (AISI 1010) with dimension of 7 cm × 10 cm and 0.1 cm thickness were degreased in an alkaline solution (based on KOH, triethanolamine and K2SiO3) at 22˚C ± 2˚C, and polarization with a current density of 4 A/dm2 for 3 min. Then, these panels were rinsed in deionized water, subjected to pickling in HCl 1:1 with an iron inhibitor for 1 min, newly rinsed with deionized water, activated in 5% wt ammonium bifluoride solution for 30 s, and rinsed once more in deionized water. Once this step was completed, the steel samples were electrogalvanised using a cyanide-free alkaline bath containing Zn2+ 12.5 g/L, KOH 170 g/L, K2CO3 50 g/L, leveler additive 10 mL/L, brightening agents 1 mL/L, conditioner 10 mL/L. The cathodic current density was 2 A/dm2 operated at 22˚C ± 2˚C for 45 min [32] ; these samples were identified with the symbol (Z).

Immediately after applying the electrogalvanising step, the surface was activated in 0.5% v/v HNO3 solution, pH = 1, for 10 s, rinsed in deionized water, and pretreated with any of the conversion products specified as follows:

2) Blue-colored Cr(III)-Zr(IV)-based conversion treatment (symbol ZCrZr) whose operating parameters were pH = 4.2 (adjusted with 1% v/v NaOH or 5% v/v H2SO4 solutions), immersion in the industrial bath for 30 s, temperature 22˚C ± 2˚C, and mechanical stirring. The passivation bath was composed by hexafluoro silicic acid + trivalent chromium ions + zirconium complexes (commercial product).

3) Pale iridescent colored Ce(III)-based conversion treatment (symbol ZCe) whose operating parameters were pH 3.5, immersion for 30 s, temperature 22˚C ± 2˚C, and mechanical stirring. The passivation bath was composed by 2.5 g/L CeCl3∙7H2O2, 1 mL/L H2O2, and 0.1 g/L H3BO3. The pH = 3.5 (adjusted to with 1%v/v NaOH or 5% v/v H2SO4 solutions).

4) Pale iridescent colored Ce(IV)/Ce(III) bilayer (symbol ZCeD). The first layer was obtained in 1 g/L Ce(NH4)2(NO3)6 solution, and the second one in 2.5 g/L CeCl3, 1 mL/L H2O2, and 0.1 g/L H3BO3. The operating parameters in both passivation baths were pH = 3.5 (adjusted with 1% NaOH or 5% H2SO4 solutions), immersion for 30 s, temperature 22˚C ± 2˚C, and mechanical stirring.

5) Yellow-colored Cr(VI)-based conversion treatment (symbol ZCr6) used as reference samples. The operating parameters were pH = 1.8, immersion for 30 s, temperature 22˚C ± 2˚C, and mechanical stirring. The passivation bath was composed by 4.6 g/L Na2Cr2O7, conductive salt (NaCl), and diluted HCl for pH adjustment.

At finishing the conversion treatments, the samples were rinsed in deionized water and dried for 15 min at 80˚C. All the samples were stored in desiccators at 22˚C ± 2˚C up to their use.

2.2. Thickness Measurements

Coatings thickness was measured using the X-Ray Fluorescence Method, Helmut Fischer mod XDL-B according to the ASTM B568-98 standard [65] .

2.3. Electrochemical and Corrosion Behavior

The corrosion resistance of the conversion coatings was evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy in aerated 0.05 mol/L NaCl or 0.1 mol/L Na2SO4 solutions at 22˚C ± 2˚C.

The electrochemical cell consisted of a classic three-electrode arrangement, where the counter electrode was a Pt mesh, the reference a Saturated Calomel Electrode (SCE = +0.244 V vs. NHE), and the tested specimen acted as the working electrode. The area of the working electrode exposed to the electrolyte solution was 15.9 cm2.

The potentiodynamic polarization curves were acquired by a Potentiostat/Galvanostat Solartron 1280 at a swept rate of 0.2 mV/s, over the range ±0.250 V/(SCE) from the corrosion potential (Ecorr). The electrode potentials were stabilized for 10 min in the electrolyte solution before starting each test. The inhibitive eficiency (E%) was calculated from the following equation [66] :

E % = ( j c o r r - 0 j c o r r - i / j c o r r - 0 ) × 100

where:

jcorr-0 is the corrosion current density of the bare galvanized steel sheet; and

jcorr-i is the corrosion current density of the galvanized steel sheet protected by the i-conversion coating.

The EIS tests were performed with a Solartron 1255 Frequency Response Analyser® (FRA) coupled to an Impedance Potentiostat-Galvanostat Omnimetra PG-19A®, and both controlled by the ZPlot®. The measurements were performed at the Ecorr in the 105 to 10−1 Hz frequency range, as a function of the exposure time in the electrolyte solution. A sinusoidal signal with 8 mV of amplitude was applied, and the acquisition rate was 10 points/decade. The Ecorr was recorded before and after the finishing point of each experiment to verify that the stationary requirement was obeyed.

The experimental spectra were fitted and interpreted on the basis of equivalent electrical circuits using the software developed by Boukamp [67] . All impedance measurements were carried out with the electrochemical cell inside a Faraday cage to reduce external interferences as much as possible.

Considering that the corrosion resistance of passivated materials depends on the production procedure, each test was performed on three replicates of each samples type, and the reported results in the following Tables and Figures are the average of them.

3. Results and Discussion

3.1. Chemical Physical Characteristics and Thickness Measurements

The identification symbol, description and thickness measurements of the investigated samples are summarized in Table 1. It can be observed that the samples present similar coating thickness. As it was not possible to obtain information about the passive layer thickness, the values shown in Table 1 correspond to the total coating thickness (zinc + passive layer).

3.2. Polarization Curves

Potentiodynamic measurements were performed to study the corrosion behavior of electrogalvanised steel/conversion layer systems in comparison to the electrogalvanised steel sheets without treatment and in contact with aerated 0.05 mol/L NaCl or 0.1 mol/L Na2SO4 solution at 22˚C ± 2˚C. Four coating compositions were studied corresponding to the ZCe, ZCeD, ZCrZr and ZCr6 samples,

Table 1. Identification, description and coating thickness of the tested samples.

respectively. The potentiodynamic curves are shown in Figure 1(a) and Figure 1(b), and both the corrosion potential (Ecorr) and corrosion current density (jcorr) values obtained from the Tafel extrapolation method are collected in Table 2. It also presents the calculated polarization resistance (Rp) and protective efficiency percentage (E%)values offered by each of the investigated samples.

Potentiodynamic curves obtained in aerated 0.05 mol/L NaCl solution for all the tested surface conditions are displayed in Figure 1(a). The results show similar anodic and cathodic characteristics for the bare zinc coating (Z), or those covered ZCe or ZCeD conversion layers, with a slight polarization of the cathodic reactions and a strong dissolution tendency in the anodic ones. For these samples type, the main cathodic reaction (oxygen reduction) produces OH ions,

Figure 1. Polarization curves for the electrogalvanised samples without or with surface passivation treatments. Electrolyte: (a) 0.05 M NaCl solution; (b) 0.1 mol/L Na2SO4.

which react with the Zn2+ coming from the anodic areas to form zinc corrosion products. These, combined with the Cl electrolyte ions, lead to the formation of Simonkolleite and/or other zinc-chloride charged ions [68] [69] and, as a consequence, to a certain diffusional controlled tendency, which indicates that in Cl medium these sample types are more inclined to inhibit the cathodic reaction due to the high water permeability and porous nature of the protective layers [70] [71] [72] [73] . Both the pure zinc coating and the conversion layers defects lead to anodic depolarization, whereas the conversion layer deposition on partial substrate areas would be the reason for the slight cathodic polarization reaction on the ZCe and ZCeD samples.

On the contrary, the anodic and cathodic branches of the ZCrZr and ZCr6 samples presented significant differences regarding the above tested samples. The Ecorr value of the chromium treated samples was comparatively more negative than the measured in the other ones. Their potentiodynamic curves show that after an active dissolution the ZCrZr and ZCr6 samples revealed a passive behavior until approximately −0.96 V/SCE when the passive film formed on both sample surfaces was broken causing the restarting of the substrate active dissolution. As well, the cathodic polarization curves of the ZCr6 samples indicated an activation control, while the corresponding to the ZCrZr samples was very different.

The results also show that the reaction mainly depolarized by the chromate formed passivating film was the cathodic one. A comparison of the ZCrZr and ZCr6 treatments reveals that the first was related to much lower anodic or cathodic current densities and presented a corrosion potential whose current density (<10−6 A∙cm−2, Table 2) is typical of passive materials. This indicates that

Table 2. Electrochemical parameters obtained from polarization curves.

potential instabilities due to environmental changes in the potential range until passive film breakdown does not lead to highly corrosive and harmful conditions once the passive film stays on the surface, showing that it is a highly protective film. The lowest anodic and cathodic current densities associated to this type of sample show that the conversion layer polarizes the anodic and cathodic reactions, although its breakdown resistance was like the ZCr6 coating. The high corrosion protection that the ZCrZr film afforded to the substrate could be due to the Zr component, however, the Cr3+ component plays an important role contributing to the enhancement of the barrier properties.

Polarization curves obtained in aerated 0.1 mol/L Na2SO4 solution at (22˚C ± 2˚C) for all the tested surface conditions are presented in Figure 1(b). As seen in Figure 1(a), de DC data obtained on zinc (Z) and coated samples (ZCe or ZCeD) confirm that these conversion layers do not significantly affect the electrochemical behavior of the electrogalvanised steel. Therefore, it is possible to assume that the Ce-based conversion layers produced in both cases cannot protect the electrogalvanised steel as a barrier. On the contrary, the ZCrZr and ZCr6 samples show a noticeable jcorr decrease, Table 2. In that sense, the anodic and cathodic characteristics of ZCrZr and ZCr6 samples presented large differences from the Z ones. As seen, reduction of the anodic slope and shifting of Ecorr towards more cathodic domains occurs. The higher barrier properties provided by the ZCrZr coating can be ascribed to both the stability and presence of Cr2O3 and Zr complexes, respectively.

3.3. Impedance Measurements

Examples of the impedance spectra in Bode form obtained at different exposure times in aerated 0.05 mol/L NaCl or 0.1 mol/L Na2SO4 solution at (22˚C ± 2˚C) are shown in Figure 2 and Figure 3, respectively.

Figure 2 displays the impedance evolution of electrogalvanised steel samples, either without or with passivation treatments, after potential stabilization in aerated 0.05 mol/L NaCl solution. Two time constants were indicated in the impedance spectra of the untreated electrogalvanised sample, the one at the higher frequencies (HF) likely due to the presence of zinc corrosion products, and the one at the lower frequencies associated to charging of the electrochemical double layer in parallel with the charge transfer processes at the zinc/solution interface. The HF time constant dislocated into lower frequencies with the immersion time, due to the slowing down of the dissolution processes as result of the increasing zinc corrosion products formed on the electrogalvanised surface. Similar effects were obtained for ZCe or ZCeD samples, however, for these last samples types, the second time constant at lower frequencies are not well defined. Besides, the electrochemical response of a Ce conversion layer, usually seen at high frequencies was not identified on neither of the two types of the tested Ce surface coatings.

The impedance spectra for ZCrZr samples show higher impedance values

Figure 2. Effect of immersion time in naturally aerated 0.05 mol/L NaCl solution on the Bode plots of the tested samples at (a) 0 d; (b) 1 d; (c) 2 d; and (d) 3 d.

Figure 3. Effect of immersion time in naturally aerated 0.1 mol/L Na2SO4 solution on the Bode plots of the tested samples at (a) 0 d; (b) 1 d; (c) 2 d; and (d) 3 d.

associated to these samples compared to the other tested surface treatments, and the protection afforded lasted for longer periods than for the previous ones. The protection afforded lasted for at least 1 d and deteriorated between 1 and 2 d in the exposed ZCrZr samples, whereas for the ZCr6 samples the protection afforded increased with time until 1 d, likely due to precipitation of protective products on the surface, characteristic of this type of layer, being fairly stable until 3 d when the test was concluded. For these two treatments, two times constants were identified, being clearly separated for the ZCr6 samples. These results show that the protection afforded by the Cr(VI) conversion layer not only was greater than the provided by the ZCrZr layer containing trivalent chromium and fluorzirconium particles, but also offered longer duration.

Figure 3 exhibits the evolution of the electrogalvanised steel samples impedance spectra, either without or with passivation treatments, after potential stabilization in aerated 0.1 mol/L Na2SO4 solution. This Figure shows that the ZCrZr and ZCr6 samples provided the largest impedance (over almost the frequency range) while the Z, ZCe and ZCeD samples presented lower and very similar impedance values for the 3 days of immersion. Also, in this electrolytic medium the Bode diagrams show at least two well-defined time constants at the different immersion times tested. However, the deconvolution of these diagrams through the fitting program showed that, in some cases, there were overlapping time constants (not detectable by naked eye), which is why their number could be greater than 2. In accordance with the results obtained in the DC tests, the higher barrier properties provided by the ZCrZr coating can be ascribed to both the stability and presence of Cr2O3 and Zr complexes, while the corresponding to the ZCr6 samples to the effective passivating action offered by the Cr(VI)-based bath.

In this study, the impedance data of pure zinc coating, and the Cr(III) + Zr complex layer, Ce(III) layer, Ce(IV)/Ce(III) double layer or Cr(VI)-treated surfaces can be fitted by the complete or partial version of the equivalent circuit proposed in Figure 4. In this equivalent circuit, Rs represents the electrolyte resistance, R1 the resistance to the ionic flux in the pore and C1 the dielectric capacitance of the conversion layer. The R2 and C2 parameters account for the charge transfer resistance and the electrochemical double layer capacitance of the corrosion process, respectively [19] [74] . As immersion time and zinc dissolution increases, corrosion products could accumulate at the bottom or within the pores. In such circumstances, their contribution to the system impedance would be characterized by the R3 and C3 parameters [19] [74] - [80] . The diffusion component W obtained at certain exposure times was associated with an oxygen diffusion-controlled reaction usually found in zinc corrosion [81] [82] .

The values of the R1, C1, R2, C2, R3, and C3 parameters estimated from the analysis of the impedance spectra fitting as a function of immersion time in 0.05 mol/L NaCl or 0.1 mol/L Na2SO4 are reported in Figures 5(a)-(e) and Figures 6(a)-(g), respectively.

Figure 4. Equivalent circuits used to model the experimental impedance data of the tested samples as a function of the immersion time in naturally aerated 0.1 mol/L Na2SO4 or 0.05 mol/L NaCl solutions.

Figure 5. Time dependence of the resistive-capacitive components of the impedance corresponding to the tested samples immersed in naturally aerated 0.05 mol/L NaCl for 3 d.

3.4. Evolution of Samples, Ecorr and Impedance Components with the Immersion Time

Figures 5(a)-(e) show the evolution of the Ecorr and each component of the equivalent circuit as a function of immersion time of the bare or coated electrogalvanised steel sheets in contact with naturally aerated 0.05 mol/L NaCl solution.

Figure 6. Time dependence of the resistive-capacitive components of the impedance corresponding to the tested samples immersed in naturally aerated 0.1 mol/L Na2SO4 solution for 3 d.

As previously mentioned, the poor barrier properties provided by the conversion layer made possible that the zinc corrosion reaction initiated just after immersion. In general terms, the displacements shown during the immersion test by the Ecorr values corresponding to the different samples can be attributed to the following effects: the decrease of such values were caused by the activation of the zinc areas at the bottom of the conversion layers defects (micropores, microcracks) due to their interaction with the Cl ions present in the electrolyte. The activation mechanism includes the replacement of the outer part of the zinc oxides by zinc corrosion products, which are less protective than the original oxides. This change enhances electrochemical reactions such as the zinc anodic dissolution. On the contrary, the displacement of the Ecorr values towards nobler values observed for the different samples can be associated to the delay or polarization of the surface reactions between the electrochemically active areas of zinc and the electrolyte due to certain protective capacity developed by the corrosion products on the zinc surface and/or within and at the bottom of the conversion layers defects. This is to attenuate the zinc dissolution rate (anodic reaction) and/or the diffusion of oxygen to cathodic zones.

The results obtained from the fitting procedure described in the above paragraph are shown in Figures 5(b)-(e). The chi squared (χ2) value for the fitting was ≤5 × 10−4 (the smaller this value is, the closer to fit to the experimental data).

Suzuki and Venkatesan [83] [84] studied the corrosion products of zinc in Cl media. According to these authors, zinc is always covered by a ZnO layer and, depending on the environment humidity, Zn(OH)2 may also be present, which act as a protective barrier preventing corrosion. During the exposure to the aerated 0.05 mol/L NaCl solution for 72 h one interesting observation was that the corrosion of the Z samples was reasonably localized, i.e. it started at small areas and then it changed from side to side along the surface. The corrosion process started with the attack of the zinc oxide/hydroxide barrier by the action of H2O and Cl ions and zinc dissolution occurred not in uniform way, but in local areas.

The more interesting data to discuss are the resistance of the chemical conversion layer R1 (giving information on the barrier properties of this layer) and the charge transfer resistance R2 (giving information on the kinetic of the corrosive process). An example of evolution of the coating resistance (R1) for the Z samples is in Figure 5(b). The same Figure shows that the resistance provided by the ZCrZr and ZCr6 pretreatments offers a higher protection, in comparison with the ZCe and ZCeD pretreatments.

Particularly for the ZCr6 samples along throughout the test, and for the ZCrZr for the first day of immersion, this fact has a strong influence on the charge transfer resistance and therefore on the corrosion rate (Figure 5(d)). Generally, the decrease of R1 (Figure 5(b)) and increase of C1 (Figure 5(c)) indicates that the blocking performance of the conversion layer has been gradually disappearing [17] [85] . The decline of the anticorrosive performance is attributed to local microcracks formed on the conversion-coating layer. Comparing with the initial stage, the microcracks have propagated throughout the coating surface during the immersion. On the contrary, the trend of the resistance inside the defects (R1) to show certain increase and/or of the coating capacitance (C1) to decrease can be related to the formation and gathering of the zinc corrosion products.

During the same testing time, the evolution of R2 values (Figure 5(d)) reflect the variability of the active surface where corrosion occurs and, hence, the protection effectiveness. In that sense, it is remarkable that passivation-activation can occur simultaneously on the zinc surface with different extension. The higher protection efficiency for the 3 days of immersion was provided by the ZCr6 pretreatment due to the passivation action of the mobile Cr6+ ions available in the coating, followed by the ZCrZr whose protective action has been attributed to both the Zr and the Cr3+ components, as it was established when discussing the results with DC. On the other hand, the R2 values in the ZCe and ZCeD samples dropped drastically during the first day of immersion but then remained almost constant until the end of the test. In all the cases, the presence of a plateau region during the test indicates that a dynamic equilibrium between the anodic and cathodic reactions is reached and suggest a lateral surface coverage of the conversion coating.

The increasing of R2 means that the charge transfer resistance between the zinc and the solution becomes more difficult due to the passivation property afforded by the corresponding conversion coating layer during the immersion. The decreasing of R2 indicates a progressive drop of the protection provided by the conversion layer. The C2 values (Figure 5(e)) are proportional to the area involved in the electrochemical reactions, i.e., the area of microcracks in contact with the solution. Therefore, an increasing indicates that the corrosion inside the microcracks becomes more severe and the microcracks area increases with the immersion time.

Figure 6 shows the evolution of the Ecorr (a), and of each component obtained from the impedance data deconvolution (b-g) for pure or coated electrogalvanised steel sheets immersed for 3 days in naturally aerated 0.1 mol/L Na2SO4 solution. As seen in Figure 6(a), in comparison with the changes in the Ecorr values obtained for the samples tested in contact with NaCl, the measured for their replicates for the same testing time in Na2SO4 solution were much less important. In this case, the most significant displacement (±0.060 V/SCE) occurred in the ZCeD sample, while in the rest, a shift mostly towards slightly more positive values took place. This shift is concern with a slow increase in the amount of corrosion products within the conversion layers defects, which act as a diffusion barrier to ions such as SO 4 2 through the conversion layer. However, with the increasing of the immersion time it can be expected that the corrosion inside the defects of the conversion layer become more severe and the cracks occurs, this was may be what happened with the ZCeD samples. Another possibility is that the corrosion products inside the defects loosened and diffuse towards the solution. In this case, the barrier effect is lost, and zinc dissolution is increased, generating new corrosion products and, therefore, a new barrier effect that reduces the electrochemically active areas making that the Ecorr moves towards nobler values.

In Figure 6(b) it is possible to note an increase of the conversion layer resistance (R1) values along the 72 h of immersion for the Z, ZCe and ZCr6 samples. On the contrary, those corresponding to the ZCeD and ZCrZr ones decreased within the first 24 h but then remained constant up to the end of the test. As seen, the R1 values were mostly greater for the Z, ZCe and ZCr6 than those for the ZCeD and ZCrZr samples. Despite this, the charge transfer resistance (R2) (Figure 6(d)) values not only for the ZCr6 but also for the ZCrZr samples were greater than those for the ZCe and ZceD samples, and all of them higher than for the Z ones. This means that to a greater or lesser extent all the conversion coatings were able to reduce the zinc corrosion rate throughout the test. It is assumed that the particularly anomalous behavior of the ZCrZr samples, this is low R1 but high R2 values, could be because the local microcracks formed on this conversion layer do not affect its very effective passivating effect.

The dielectric capacity (C1) evolution for the pure zinc (Z) and the four conversion films tested is shown in Figure 6(c). In this the C1 value remained nearly constant for all the samples, but also that it was almost two orders of magnitude smaller for the better and more protected ZCr6 and ZCrZr samples. This consistency throughout the test was attributed to the fact that once the conversion layer microdefects were full of solution, both the microdefects number and size as well as the dielectric constant value of the electrolyte accumulated inside them remained unchanged.

The electrochemical double layer capacity (C2) initially increased with the immersion time but then remained almost stable for the Z, ZCe, and ZCeD samples, Figure 6(e). As occurred with the coating dielectric capacity (C1), the C2 value was less for the ZCr6 and ZCrZr than for Z, ZCe, and ZCeD samples. The C2 value is proportional to the area involved in the electrochemical reactions, i.e. the area of microdefects in contact with the electrolyte. Therefore, changes in C2 indicate that the corrosion inside of such microdefects become more severe if the electrochemically active areas increase, or else that these latter decrease due to the gathering of corrosion products within and/or the bottom of those microdefects. Finally, another possibility is that its value remains constant if the anodic areas/cathodic areas ratio does not change, as mostly occurred in the case of the ZCr6 and ZCrZr samples.

The time constant (R3C3) at the lowest frequency region corresponds to the corrosion products formed in the micropores or microcracks of the conversion layer. Its presence indicates that the conversion coating has been penetrated by the corrosive medium and corrosion reacts on the zinc coating. Again, the stability over the time as well as the higher R3 and lower C3 values (Figure 6(f) and Figure 6(g)) evidence that the conversion layer based on Cr(VI) provided the best protective behavior against the pure zinc corrosion in such an aggressive environment for this last metal as it is that containing SO 4 2 ions. Figure 6(f) also shows that except at the beginning of the test, after 24 h of immersion in 0.1 mol/L Na2SO4 solution, the resistive behavior of the corrosion products formed in the Z, ZCe, ZCeD, and ZCrZr samples was similar and constant. As it happened with the evolution of the parameters discussed in the previous paragraphs, the R3 values stability is indicative that, for these exposure conditions, the corrosion process as well as the blocking action exerted by the corrosion products reached a steady state that lasted until the end of the test. The contribution of the corrosion products capacity (C3) to the impedance of each tested sample is shown in Figure 6(g). As seen, the C3 values did not change significantly; this suggests that the surface area of the corrosion products in contact with the electrolyte neither did it throughout the 72 h of immersion. According to the results obtained with all the resistive and capacitive parameters contributing to the impedance measured for each sample as a function of the immersion time, after a short time of initiation the corrosion processes developed in each of them reached a relative and permanent steady state.

4. Conclusions

The potentiodynamic polarization and EIS techniques allowed the evaluation of the protective efficiency for the tested systems, which was different depending on the conversion layer formulation used to protect the electrogalvanised steel sheets.

The electrochemical behavior of the coated electrogalvanised steel sheets under immersion conditions could be modelled using a different number of time constants hierarchically distributed considering the presence of the conversion layer and both its microcracks and the corrosion products deposited in them. The high frequency time constant (R1C1), was related to the dielectric properties of the conversion layer; the second time constant (R2C2) refers to the zinc corrosion process, while the third one (R3C3) was associated to the presence and dielectric behavior of the zinc corrosion products. The evolution of these parameters pointed out that: 1) in contact with the 0.05 mol/L NaCl solution the higher protection efficiency was provided by the ZCrZr-based coating (96.32%) followed by the ZCr6-one (86.45%), while the less effective corresponded to the ZCe and ZCeD-based coatings, 13.82% and 15.79%, respectively; and 2) in the 0.1 mol/L Na2SO4 solution, the afforded protection degree by the ZCrZr and ZCr6 coatings was again very significant, 96.24% and 98.16%, respectively, but almost negligible (4.80%) by the ZCe-one. An opposite effect to the expected one presented the ZCeD coating since its presence accelerated the corrosion rate of the base substrate by an estimated value of 15.2%.

Although the presence of chromates, particularly those based on hexavalent chromium Cr(VI), remains at the forefront as a corrosion inhibitor of the steel family, the intense research carried out in different laboratories around the world to replace them with other types of coatings being more friendly to the human health and the environment is providing more and more encouraging knowledge. As examples of this, results produced by studies like the one here presented show that new and complex formulations based on a range of rare-earth metal (La, Y, Nd, Gd) salts were shown to be good corrosion inhibitors, acting by reducing the cathodic oxygen reduction reaction. In the same way, organic carboxylate compounds (such as salicylate and cinnamate) at relatively high concentrations, were found to be efficient anodic inhibitors by forming a protective layer, mainly at the anodic sites.

Acknowledgements

The authors acknowledge the Brazilian research agency FAPESP (Process 2015/0995-2 and Process 2016/50454-6), Comisión de Investigaciones Científicas de la Provincia de Buenos Aires (CICPBA), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), and Universidad Nacional de La Plata (UNLP) of Argentina for their financial support to this research.

Conflicts of Interest

The authors declare no conflicts of interest regarding the publication of this paper.

Cite this paper

Sarli, A.R.D., Elsner, C.I., Palomino, L.E.M. and Tomachuk, C.R. (2019) Corrosion Performance of Conversion Treatments for Electrogalvanised Steel Sheet. Journal of Minerals and Materials Characterization and Engineering, 7, 307-329. https://doi.org/10.4236/jmmce.2019.75022

References

  1. 1. Kelly, R.G, Scully, J.R., Shoesmith D.W. and Buchheit, R.W. (2003) Conversion Coating. In: Electrochemical Techniques in Corrosion Science and Engineering, Marcel Dekker Inc., New York, 282-286.

  2. 2. Chang, Y.-T., Wen, N.-T., Chen, W.-K., Ger, M.-D., Pan, G.-T. and Yang, T.C.-K. (2008) The Effects of Immersion Time on Morphology and Electrochemical Properties of the Cr(III)-Based Conversion Coatings on Zinc Coated Steel Surface. Corrosion Science, 50, 3494-3499. https://doi.org/10.1016/j.corsci.2008.08.051

  3. 3. Ferreira-Jr., J.M., Rossi, J.L., Baker, M.A., Hinder, S.J. and Costa, I. (2014) Deposition and Characterization of a New Mixed Organic/Inorganic Cerium Containing Coating for the Corrosion Protection of Eletrogalvanized Steel. International Journal of Electrochemical Science, 9, 1827-1839.

  4. 4. Ferreira-Jr, J.M., Souza, K.P., Rossi, J.L., Costa, I., Trindade, G.F. and Tomachuk, C.R. (2016) Corrosion Protection of Galvanized Steel by Surface Treatments Containing Cerium and Niobium Compounds. International Journal of Electrochemical Science, 11, 6655-6672. https://doi.org/10.20964/2016.08.19

  5. 5. Wilcox, G.D. and Gabe, D.R. (1987) Passivation Studies Using Group VIA Anions. V. Cathodic Treatment of Zinc. British Corrosion Journal, 22, 254-258. https://doi.org/10.1179/000705987798271244

  6. 6. Wilcox, G.D., Gabe, D.R. and Warwick, M.E. (1988) The Development of Passivation Coatings by Cathodic Reduction in Sodium Molybdate Solutions. Corrosion Science, 28, 577-587. https://doi.org/10.1016/0010-938X(88)90025-X

  7. 7. Korobov, V.I., Loshkarev, Y.M. and Kozhura, O.V. (1998) Cathodic Treatment of Galvanic Zinc Coatings in Solutions of Molybdates. Russian Journal of Electrochemistry, 34, 1154-1157.

  8. 8. Deck, P.D. and Reichgott, D.M. (1992) Characterization of Chromium-Free No-Rinse Prepaint Coatings on Aluminium and Galvanized Steel. Metal Finishing, 90, 29-35.

  9. 9. Hinton, B.R.W. (1991) Corrosion Prevention and Chromates, the End of an Era? Metal Finishing, 89, 55-61.

  10. 10. Hinton, B.R.W. (1991) Corrosion Prevention and Chromates, the End of an Era? Metal Finishing, 89, 15-20.

  11. 11. Barbucci, A., Delucchi, M. and Cerisola, G. (1998) Study of Chromate-Free Pretreatments and Primers for the Protection of Galvanised Steel Sheets. Progress in Organic Coatings, 33, 131-138. https://doi.org/10.1016/S0300-9440(98)00046-0

  12. 12. Wilcox, G.D. and Wharton, J.A. (1997) A Review of Chromate Free-Passivation Treatments for Zinc and Zinc Alloys. Transactions of the Institute of Metal Finishing, 75, B140-B146.

  13. 13. Child, T.F. and van-Ooij, W.J. (1999) Application of Silane Technology to Prevent Corrosion of Metal and Improve Paint Adhesion. Transactions of the Institute of Metal Finishing, 77, 64-70. https://doi.org/10.1080/00202967.1999.11871249

  14. 14. González, S., Gil, M.A., Hernández, J.O., Fox, V. and Souto, R.M. (2001) Resistance to Corrosion of Galvanized Steel Covered with an Epoxy—Polyamide Primer Coating. Progress in Organic Coatings, 41, 167-170. https://doi.org/10.1016/S0300-9440(01)00139-4

  15. 15. Tsai, Y.-T., Hou, K.-H., Bai, C.-Y., Lee, J.L. and Ger, M.-D. (2010) The Influence on Immersion Time of Titanium Conversion Coatings on Electrogalvanized Steel. Thin Solid Films, 518, 7541-7544. https://doi.org/10.1016/j.tsf.2010.05.042

  16. 16. Zou, Z., Li, N., Li, D., Liu, H. and Mu, S. (2011) A Vanadium-Based Conversion Coating as Chromate Replacement for Electrogalvanized Steel Substrates. Journal of Alloys and Compounds, 509, 503-507. https://doi.org/10.1016/j.jallcom.2010.09.080

  17. 17. Zhang, F., Ju, P., Pan, M., Zhang, D., Huang, Y., Li, G. and Li, X. (2018) Self-Healing Mechanisms in Smart Protective Coatings: A Review. Corrosion Science, 144, 74-88. https://doi.org/10.1016/j.corsci.2018.08.005

  18. 18. Zaki, N. (2007) Trivalent Chrome Conversion Coating for Zinc and Zinc Alloys. Metal Finish, 105, 425-435. https://doi.org/10.1016/S0026-0576(07)80361-8

  19. 19. Di Sarli, A.R., Culcasi, D., Tomachuk, C.R., Ferreira-Jr., J.M. and Costa, I. (2014) A Conversion Layer Based on Trivalent Chromium and Cobalt for the Corrosion Protection of Electrogalvanized Steel. Surface and Coatings Technology, 258, 426-436. https://doi.org/10.1016/j.surfcoat.2014.08.057

  20. 20. Bibber, J. (2016) An Overview of Nonhexavalent Chromium Conversion Coatings Part II. Metal Finishing, 100, 98-102. https://doi.org/10.1016/S0026-0576(02)80162-3

  21. 21. Jeffcoate, C.S., Isaacs, H.S., Aldykiewicz-Jr., A.J. and Ryan, M.P. (2000) Chromate in Conversion Coating: A XANES Study of Its Concentration and Mobility. Journal of the Electrochemical Society, 147, 540-547. https://doi.org/10.1149/1.1393229

  22. 22. Kendig, M., Jeanjaquet, S., Addison, R. and Waldrop, J. (2001) Role of Hexavalent Chromium in the Inhibition of Corrosion of Aluminum Alloys. Surface and Coatings Technology, 140, 58-66. https://doi.org/10.1016/S0257-8972(01)01099-4

  23. 23. Xia, L., Akiyama, E., Frankel, G. and McCreery, R.L. (2000) Storage and Release of Soluble Hexavalent Chromium from Chromate Conversion Coatings. Journal of the Electrochemical Society, 147, 2556-2562. https://doi.org/10.1149/1.1393568

  24. 24. Zhao, J., Xia, L., Sehgal, A., Lu, D., McCreery, R.L. and Frankel, G.S. (2001) Effects of Chromate Conversion Coatings on Corrosion of Aluminum Alloy 2024-T3. Surface and Coatings Technology, 14, 51-57. https://doi.org/10.1016/S0257-8972(01)01003-9

  25. 25. Kim, H.-J., Zhang, J., Yoon, R.-H. and Gandour, R. (2004) Development of Environmentally Friendly Nonchrome Conversion Coating for Electrogalvanized Steel. Surface and Coatings Technology, 188-189, 762-767. https://doi.org/10.1016/j.surfcoat.2004.07.047

  26. 26. Wen, N.T., Chen, F.J., Ger, M.D., Pan, Y.N. and Lin, C.S. (2008) Microstructure of Trivalent Chromium Conversion Coating on Electrogalvanized Steel Plate. Electrochemical and Solid-State Letters, 11, c47-c50. https://doi.org/10.1149/1.2932053

  27. 27. Rosalbino, F., Scavino, G., Mortarino, G., Angelini, R. and Lunazzi, G. (2011) EIS Study on the Corrosion of a Cr(III)-Based Conversion Coating on Zinc Galvanized Steel for the Automotive Industry. Journal of Solid State Electrochemistry, 15, 703-709. https://doi.org/10.1007/s10008-010-1140-7

  28. 28. Guo, X., Wang, Y. and Sun H. (2012) Comparative Research on Properties of Trivalent and Hexavalent Passive Film on Galvanized Steel. Advanced Materials Research, 396-398, 1760-1763. https://doi.org/10.4028/www.scientific.net/AMR.396-398.1760

  29. 29. Zhang, X., van den Bos, C., Sloof, W.G., Terryn, H., Hovestad, A. and de Wit, J.H.W. (2004) Investigation of Cr(III)-Based Conversion Coatings on Electrogalvanised Steel. Surface Engineering, 20, 244-250. https://doi.org/10.1179/026708404225016436

  30. 30. Zhang, X., van den Bos, C., Sloof, W.G., Hovestad, A., Terryn, H. and de Wit, J.H.W. (2005) Comparison of the Morphology and Corrosion Performance of Cr(VI) and Cr(III)-Based Conversion Coating on Zinc. Surface and Coatings Technology, 199, 92-104. https://doi.org/10.1016/j.surfcoat.2004.12.002

  31. 31. Almeida, E., Diamantino, T.C., Figueiredo, M.O. and Sá, C. (1998) Oxidizing Alternative Species to Chromium VI in Zinc Galvanised Steel Surface Treatment. Part 1. A Morphological and Chemical Study. Surface and Coatings Technology, 106, 8-17. https://doi.org/10.1016/S0257-8972(98)00464-2

  32. 32. Almeida, E., Fedrizzi, L. and Diamantino, T.C. (1998) Oxidizing Alternative Species to Chromium VI in Zinc Galvanised Steel Surface Treatment. Part 2. An Electrochemical Study. Surface and Coatings Technology, 105, 97-101. https://doi.org/10.1016/S0257-8972(98)00476-9

  33. 33. Tomachuk, C.R., Elsner, C.I. and Di Sarli, A.R. (2012) Behavior of Electrogalvanized Steel Pre-Treated with Cr-(III)-Based Baths and Exposed to 0.5 M Na2SO4 Solution. Portugaliae Electrochimica Acta, 30, 145-162. https://doi.org/10.4152/pea.201203145

  34. 34. Deck, P.D., Moon, M. and Sujdak, R.J. (1998) Investigation of Fluoacid Based Conversion Coatings on Aluminum. Progress in Organic Coatings, 34, 39-48. https://doi.org/10.1016/S0300-9440(98)00017-4

  35. 35. Gusmano, G., Montesperelli, G., Rapone, M., Padeletti, G., Cusmà, K.S., Mezzi, A. and Di Maggio, R. (2007) Zirconia Primers for Corrosion Resistant Coatings. Surface and Coatings Technology, 201, 5822-5828. https://doi.org/10.1016/j.surfcoat.2006.10.036

  36. 36. Fedrizzi, L., Rodríguez, F.J., Rossi, S., Deflorian, F. and Di Maggio, R. (2001) The Use of Electrochemical Techniques to Study the Corrosion Behaviour of Organic Coatings on Steel Pretreated with Sol-Gel Zirconia Films. Electrochimica Acta, 46, 3715-3724. https://doi.org/10.1016/S0013-4686(01)00653-3

  37. 37. Tepe, B. and Gunay, B. (2009) Evaluation of Environmentally Friendly Zr Based Nano Structured Conversion Coating for HRS (Hot Rolled Steel) in Powder Coating. Defect and Diffusion Forum, 283-286, 316-322. https://doi.org/10.4028/www.scientific.net/DDF.283-286.316

  38. 38. Puomi, P., Fagenholme, H.F., Rosenholme, J.B. and Sipila, R. (1999) Optimization of Commercial Zirconic Acid Based Pretreatment on Hot-Dip Galvanized and Galfan Coated Steel. Surface and Coatings Technology, 115, 79-86. https://doi.org/10.1016/S0257-8972(99)00171-1

  39. 39. Yen, S.K., Guo, M.J. and Zan, H.Z. (2001) Characterization of Electrolytic ZrO2 Coating on Co-Cr-Mo Implant Alloys of Hip Prosthesis. Biomaterials, 22, 125-133. https://doi.org/10.1016/S0142-9612(00)00133-2

  40. 40. Zhitomirsky, I. and Petric, A. (2000) Electrolytic Deposition of Zirconia and Zirconia Organoceramic Composites. Materials Letters, 46, 1-6. https://doi.org/10.1016/S0167-577X(00)00133-6

  41. 41. Balamurugan, A., Kanan, S. and Rajeshwari, S. (2003) Structural and Electrochemical Behaviour of Sol-Gel Zirconia Films on 316L Stainless Steel in Simulated Body Fluid Environment. Materials Letters, 57, 4202-4205. https://doi.org/10.1016/S0167-577X(03)00290-8

  42. 42. Quinson, J.F., Chino, C., De Becdelievre, A.M., Guizard, C. and Brunel, M. (1996) Deformation Capability and Protective Role of Zirconia Coatings on Stainless Steel. Journal of Materials Science, 31, 5179-5184. https://doi.org/10.1007/BF00355922

  43. 43. Choy, K.L. (2003) Chemical Vapour Deposition of Coatings. Progress in Materials Science, 48, 57-170. https://doi.org/10.1016/S0079-6425(01)00009-3

  44. 44. Ferrari, B. and Moreno, R. (2000) Zirconia Thick Films Deposited on Nickel by Aqueous Electrophoretic Deposition. Journal of the Electrochemical Society, 147, 2987-2992. https://doi.org/10.1149/1.1393636

  45. 45. Andreatta, F., Aldighieri, P., Pausa, L., Di Maggio, R., Rossi, S. and Fedrizzi, L. (2007) Electrochemical Behaviour of ZrO2 Sol-Gel Pre-Treatments on AA6060 Aluminium Alloy. Electrochimica Acta, 52, 7545-7555. https://doi.org/10.1016/j.electacta.2006.12.065

  46. 46. Ouyang, J.H. and Sasaki, S. (2001) Unlubricated Friction and Wear Behavior of Low-Pressure Plasma-Sprayed ZrO2 Coating at Elevated Temperature. Ceramics International, 27, 251-260. https://doi.org/10.1016/S0272-8842(00)00072-9

  47. 47. Moulzolf, S.C., Lad, R.J. and Blau, P.J. (1999) Microstructural Effects on the Friction and Wear of Zirconia Films in Unlubricated Sliding Contact. Thin Solid Films, 347, 220-225. https://doi.org/10.1016/S0040-6090(99)00046-2

  48. 48. Wang, J., Yang, S., Liu, X., Ren, S., Guan, F. and Chen, M. (2004) Preparation and Characterization of ZrO2 Thin Film on Sulfonated Self-Assembled Monolayer of 3-Mercaptopropyl Trimethoxysilane. Applied Surface Science, 221, 272-280. https://doi.org/10.1016/S0169-4332(03)00887-0

  49. 49. Li, H.B., Liang, K.M., Mei, L.F., Gu, S.R. and Wang, S.X. (2001) Corrosion Protection of Mild Steel by Zirconia Sol-Gel Coatings. Journal of Materials Science Letters, 20, 1081-1083.

  50. 50. Sui, J.H. and Cai, W. (2006) Formation of ZrO2 Coating on the NITI Alloys for Improving Their Surface Properties. Nuclear Instruments and Methods in Physics Research Section B, 251, 402-406. https://doi.org/10.1016/j.nimb.2006.06.028

  51. 51. Hinton, B.R.W. and Wilson, L. (1989) The Corrosion Inhibition of Zinc with Cerous Chloride. Corrosion Science, 29, 967-985. https://doi.org/10.1016/0010-938X(89)90087-5

  52. 52. Phani, A.R., Gammel, F.J., Hack, T. and Haefke, H. (2005) Enhanced Corrosion Resistance by Sol-Gel Based ZrO2-CeO2 Coatings on Magnesium Alloys. Materials and Corrosion, 56, 77-82. https://doi.org/10.1002/maco.200403823

  53. 53. Palomino, L.E.M., Aoki, I.V. and De Melo, H.G. (2006) Microstructural and Electrochemical Characterization of Ce Conversion Layers Formed on Al Alloy 2024-T3 Covered Cu-Rich Smut. Electrochimica Acta, 51, 5943-5953. https://doi.org/10.1016/j.electacta.2006.03.036

  54. 54. Arenas, M.A. and Damborenea, J.J. (2004) Surface Characterization of Cerium Layers on Galvanised Steel. Surface and Coatings Technology, 187, 320-325. https://doi.org/10.1016/j.surfcoat.2004.02.033

  55. 55. Huang, X., Li, N., Wang, H.H., Dun, H., Sun, S. and Zheng, J. (2008) Electrodeposited Cerium Film as Chromate Replacement for Tinplate. Thin Solid Films, 516, 1037-1043. https://doi.org/10.1016/j.tsf.2007.08.044

  56. 56. Salazar-Banda, G.R., Moraes, S.R., Motheo, A.J. and Machado, S.A.S. (2009) Anticorrosive Cerium-Based Coatings Prepared by the Sol-Gel Method. Journal of Sol-Gel Science and Technology, 52, 415-423. https://doi.org/10.1007/s10971-009-2031-1

  57. 57. Montemor, M.F. and Ferreira, M.G.S. (2008) Analytical Characterization of Silane Films Modified with Cerium Activated Nanoparticles and Its Relation with the Corrosion Protection of Galvanised Steel Substrates. Progress in Organic Coatings, 63, 330-337. https://doi.org/10.1016/j.porgcoat.2007.11.008

  58. 58. Motte, C., Maury, N., Olivier, M.G., Petitjean, J.P. and Willem, J.F. (2005) Cerium Treatment for Temporary Protection of Electroplated Steel. Surface and Coatings Technology, 200, 2366-2375. https://doi.org/10.1016/j.surfcoat.2004.11.032

  59. 59. Aramaki, K. (2006) The Effect of Modification with Hydrogen Peroxide on a Hydrated Cerium(III) Oxide Layer for Protection of Zinc against Corrosion in 0.5 M NaCl. Corrosion Science, 48, 766-782. https://doi.org/10.1016/j.corsci.2005.01.014

  60. 60. Aramaki, K. (2007) Protection of Zinc from Corrosion by Coverage with a Hydrated Cerium(III) Oxide Layer and Ultrathin Polymer Films of a Carboxylate Self-Assemble Monolayer Modified with Alkytriethoxysilanes. Corrosion Science, 49, 1963-1980. https://doi.org/10.1016/j.corsci.2006.07.008

  61. 61. Shibli, S.M.A. and Chacko, F. (2008) Development of Nano CeO2-Incorporated High Performance Hot Dip Zinc Coatings. Surface and Coatings Technology, 202, 4971-4975. https://doi.org/10.1016/j.surfcoat.2008.04.090

  62. 62. Hamlaoui, Y., Remazeilles, C., Bordes, M., Tifouti, L. and Pedraza, F. (2010) Electrodeposition of Ceria-Based Layers on Zinc Electroplated Steel. Corrosion Science, 52, 1020-1025. https://doi.org/10.1016/j.corsci.2009.11.027

  63. 63. Montemor, M.F., Snihirova, D.V., Taryba, M.G., Lamaka, S.V., Kartonakis, I.A., Balaskas, A.C., Kordas, G.C., Tedim, J., Kuznetsova, A., Zheludjkevich, M.L. and Ferreira, M.G.S. (2012) Evaluation of Self-Healing Ability in Protective Coatings Modified with Combinations of Layered Double Hydroxides and Cerium Molybdate Nanocontainers Filled with Corrosion Inhibitors. Electrochimica Acta, 60, 31-40. https://doi.org/10.1016/j.electacta.2011.10.078

  64. 64. Ferreira, M.G.S., Duarte, R.G., Montemor, M.F. and Simoes, A.M.P. (2004) Silane and Rare Earth Salts as Chromate Replacers for Pre-Treatments on Galvanised Steel. Electrochimica Acta, 49, 2927-2935. https://doi.org/10.1016/j.electacta.2004.01.051

  65. 65. ASTM (2014) Standard Test Method for Measurement of Coating Thickness by X-Ray Spectrometry. ASTM B568-98 (Reapproved 2014), 8 p.

  66. 66. Ozkir, D., Kayakirilmaz, K., Bayol, E., Gürten, A.A. and Kandemirli, F. (2012) The Inhibition Effect of Azure A on Mild Steel in 1M HCl. A Complete Study: Adsorption, Temperature, Duration and Quantum Chemical Aspects. Corrosion Science, 56, 143-152. https://doi.org/10.1016/j.corsci.2011.11.010

  67. 67. Boukamp, A. (1989) Equivalent Circuit. Report CT88/265/128, CT89/214/128, University of Twente, Enschede.

  68. 68. Prosek, T., Thierry, D., Taxén, C. and Maixner, J. (2007) Effect of Cations on Corrosion of Zinc and Carbon Steel Covered with Chloride Deposits under Atmospheric Conditions. Corrosion Science, 49, 2676-2693. https://doi.org/10.1016/j.corsci.2006.11.004

  69. 69. Miao, W., Cole, I.S., Neufeld, A.K. and Furman, S. (2007) Pitting Corrosion of Zn and Zn-Al in pH 2 to 12 NaCl Solutions. Journal of the Electrochemical Society, 154, C7-C15. https://doi.org/10.1149/1.2372691

  70. 70. Guin, A.A., Naik, S. and Rout, T.K. (2011) Corrosion Resistance Nano-Hybrid Sol-Gel Coating on Steel Sheet. The Iron and Steel Institute of Japan, 51, 435-440. https://doi.org/10.2355/isijinternational.51.435

  71. 71. Shreepathin, S., Guin, K.A. and Naik, M.S. (2011) Service Life Prediction of Organic Coatings: Electrochemical Impedance Spectroscopy vs. Actual Service Life. Journal of Coatings Technology and Research, 8, 191-200. https://doi.org/10.1007/s11998-010-9299-5

  72. 72. Pepe, A., Aparicio, M., Ceré, S. and Durán, A. (2004) Preparation and Characterization of Cerium Doped Silica Sol-Gel Coatings on Glass and Aluminum Substrates. Journal of Non-Crystalline Solids, 348, 162-171. https://doi.org/10.1016/j.jnoncrysol.2004.08.141

  73. 73. Bressy, C., Hghes, C. and Margaillan, A. (2009) Characterization of Chemically Active Antifouling Paints Using EIS and Erosion Tests. Progress in Organic Coatings, 64, 89-97. https://doi.org/10.1016/j.porgcoat.2008.07.014

  74. 74. Fedrizzi, L., Ciaghi, L., Bonora, B.L., Fratesi, R. and Roventi, G. (1992) Corrosion Behavior of Electrogalvanized Steel in Sodium Chloride and Ammonium Sulphate Solutions, a Study by E.I.S. Journal of Applied Electrochemistry, 22, 247-254. https://doi.org/10.1007/BF01030185

  75. 75. Tomachuk, C.R., Elsner, C.I. and Di Sarli, A.R. (2010) Morphology and Corrosion Resistance of Cr(III)-Based Conversion Treatments for Electrogalvanized Steel. Journal of Coatings Technology and Research, 7, 493-502. https://doi.org/10.1007/s11998-009-9213-1

  76. 76. Mouanga, M., Ricq, L. and Bercot, P. (2008) Electrodeposition and Characterization of Zinc-Cobalt Alloy from Chloride Bath: Influence of Coumarin as Additive. Surface and Coatings Technology, 202, 1645-1651. https://doi.org/10.1016/j.surfcoat.2007.07.023

  77. 77. Rangel, C.M. and Cruz, L.F. (1996) Zinc Dissolution in Lisbon Tap Water. Corrosion Science, 33, 1479-1493. https://doi.org/10.1016/0010-938X(92)90184-5

  78. 78. Bonora, P.L., Deflorian, F. and Fedrizzi, L. (1996) Electrochemical Impedance Spectroscopy as a Tool for Investigating under Paint Corrosion. Electrochimica Acta, 41, 1073-1082. https://doi.org/10.1016/0013-4686(95)00440-8

  79. 79. Dattilo, M. (1985) Polarization and Corrosion of Electrogalvanized Steel—Evaluation of Zinc Coatings Obtained from Waste-Derived Zinc Electrolytes. Journal of the Electrochemical Society, 132, 2557-2561. https://doi.org/10.1149/1.2113623

  80. 80. Deflorian, F., Rossi, S., Fedrizzi, L. and Bonora, P.L. (2005) EIS Study of Organic Coating on Zinc Surface Pretreated with Environmentally Friendly Products. Progress in Organic Coatings, 52, 271-279. https://doi.org/10.1016/j.porgcoat.2004.04.005

  81. 81. Cachet, C. and Wiart, R. (1980) The Kinetics of Zinc Dissolution in Chloride Electrolytes: Impedance Measurements and Electrode Morphology. Journal of Electroanalytical Chemistry, 111, 235. https://doi.org/10.1016/0368-1874(80)80256-5

  82. 82. Amirudin, A. and Thierry, D. (1995) Application of Electrochemical Impedance Spectroscopy to Study the Degradation of Polymer-Coated Metals. Progress in Organic Coatings, 26, 1-28. https://doi.org/10.1016/0300-9440(95)00581-1

  83. 83. Suzuki, I. (1985) The Behavior of Corrosion Products on Zinc in Sodium Chloride Solution. Corrosion Science, 25, 1029-1034. https://doi.org/10.1016/0010-938X(85)90070-8

  84. 84. Venkatesan, R. (1998) Study of Corrosion Product of Zinc in Natural Sea Water. British Corrosion Journal, 33, 77-80. https://doi.org/10.1179/bcj.1998.33.1.77

  85. 85. Bellezze, T., Roventi, G. and Fratesi, R. (2002) Electrochemical Study on the Corrosion Resistance of Cr3+-Based Conversion Layers on Zinc Coatings. Surface and Coatings Technology, 155, 221-230. https://doi.org/10.1016/S0257-8972(02)00047-6