Article citationsMore>>
D. M. Proctor, K. A. Fehling, E. C. Shay, J. L. Wittenborn, J. J. Green, C. Avent, R. D. Bigham, M. Connolly, B. Lee, T. O. Shepker and M. A. Zak, “Physical and Chemical Characteristics of Blast Furnace, Basic Oxygen Furnace, and Electric Arc Furnace Steel Industry Slags,” Environmental Science & Technology, Vol. 34, No. 8, 2000, pp. 1576-1582.
doi:10.1021/es9906002
has been cited by the following article:
-
TITLE:
Predicting Phosphorus Sorption onto Steel Slag Using a Flow-through approach with Application to a Pilot Scale System
AUTHORS:
Chad J. Penn, Joshua M. McGrath
KEYWORDS:
Phosphorus, By-Products, Phosphorus Removal Structure
JOURNAL NAME:
Journal of Water Resource and Protection,
Vol.3 No.4,
March
29,
2011
ABSTRACT: Reducing phosphorus (P) loads from soils to surface waters is necessary for solving the problem of eutrophication. Many industrial by-products have been shown to sorb appreciable amounts of dissolved P from solution and it has been proposed to use P sorption materials (PSMs) such as steel slag in landscape scale “filters” for trapping dissolved P in runoff. The objective of this study was to model the effect of retention time (RT) and P concentration on P sorption by steel slag and a surface modified slag in a flow-through system. Sorption of P onto steel slag and rejuvenated-modified steel slag was measured using a traditional batch isotherm and a flow-through setting at several RTs and P concentrations. Flow-through data were used to produce a model that estimated P sorption based on RT and P concentration. The model was tested on a pilot-scale pond filter consisting of the same slag materials. For both the materials, flow-through tests indicated an increase in RT increased P removal efficiency but decreased the total amount of P removed at saturation. The Langmuir model developed from batch isotherms overestimated and underestimated P sorption in normal and rejuvenated slag respectively, relative to flow-through. Normal and rejuvenated slag removed 38 and 36% of P in the pilot-scale pond filter after 2 weeks of pumping. The Langmuir equation poorly predicted P sorption in the pond filter while the flow-through model produced reasonable estimates. Results suggest that flow-through methodology is necessary for estimating P sorption in the context of landscape P filters.
Related Articles:
-
Hervé A. N’cho, Innocent K. Kouame, Kouadio Koff, Lazare K. Kouassı, Séraphin K. Konan, Ruth Baï, Andrei Sandu, Ion Sandu
-
Casimir Komenan
-
Lixia Zhang, Wei Kang, Xiaoping Zhang
-
Supratik Dash, Nachiketa Mohanty, Upendra K. Mohanty, Smarajit Sarkar
-
Miguel A. Barron, Dulce Y. Medina, Isaias Hilerio